Biomechanical behavior of titanium, cobalt-chromium, zirconia, and PEEK frameworks in implant-supported prostheses: a dynamic finite element analysis
Top Cited Papers
Open Access
- 18 January 2025
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Abstract
The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis. A 3D edentulous maxillary model was extracted from a computer tomography (CT) database. Bone level implants with conical connection designs were placed in the anterior (canine) and posterior (first molar) areas. Anterior implants were parallel, yet posterior implants were inclined distally by 30 degrees. According to the framework material, four groups were formed: cobalt-chromium (Co-Cr), zirconia (Zr), titanium (Ti), and polyether ether ketone (PEEK). For each framework material, twelve separate models of analysis were created by applying force in three different orientations. Dynamic forces were employed to replicate the chewing process. Principal and von Mises stresses were measured and evaluated. The PEEK framework exhibited the highest maximum von Mises stress values (372.55 MPa) on the abutment and the highest maximum principle stress values (59.27 MPa) in the cortical bone. The Co-Cr framework had the lowest minimum principle stress (3.98 MPa) in the trabecular bone. The displacements of the Co-Cr, Zr, Ti, and PEEK frameworks were 0.15 mm, 0.15 mm, 0.17 mm, and 0.35 mm, respectively. Frameworks having a greater Young's modulus are less susceptible to deformation.Keywords
Funding Information
- The Scientific and Technological Research Council of Turkey (TUBITAK) ARDEB 1002 (121S213, 121S213, 121S213, 121S213)
This publication has 21 references indexed in Scilit:
- Biomechanical analysis of inclined and cantilever design with different implant framework materials in mandibular complete-arch implant restorationsThe Journal of Prosthetic Dentistry, 2022
- Developments of PEEK (Polyetheretherketone) as a biomedical material: A focused reviewEuropean Polymer Journal, 2021
- A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEKScientific Reports, 2019
- Comparison between all-on-four and all-on-six treatment concepts and framework material on stress distribution in atrophic maxilla: A prototyping guided 3D-FEA studyMaterials Science and Engineering: C, 2016
- Simplified custom impression post for implant-supported restorationsThe Journal of Prosthetic Dentistry, 2016
- The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A three-dimensional finite element analysisThe Journal of Prosthetic Dentistry, 2008
- Static Versus Dynamic Loading in the Mechanical Modulation of Vertebral GrowthSpine, 2006
- Static, dynamic and fatigue behaviors of dental implant using finite element methodAdvances in Engineering Software, 2006
- Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysisThe Journal of Prosthetic Dentistry, 2004
- The implant-supported prosthesis for the edentulous arch: Design considerationsThe Journal of Prosthetic Dentistry, 1997