DHDilara Sahin Hazir

Dilara Sahin Hazir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dilara Sahin Hazir has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Knowledge and Attitudes of Undergraduate Dental Students Toward Conventional and Digital Workflows in Maxillofacial Prosthetics: A Cross-Sectional Survey

    by İrem Sözen Yanık, Aslıhan Öztürk, Aslı Bengisu Karayel, Ayberk Demirok, Dilara Sahin Hazir

    Background: Digital technologies are increasingly transforming the field of maxillofacial prosthetics; however, the extent to which undergraduate dental education has adapted to these developments remains unclear. Evaluating dental students’ knowledge and attitudes toward conventional and digital workflows is essential for identifying potential educational gaps.Methods: A cross-sectional questionnaire-based survey was conducted among 201 undergraduate dental students (99 fourth-year and 102 fifth-year) receiving clinical prosthodontic training. Data were collected using a 24-item structured questionnaire distributed online. Knowledge and attitudes were assessed using a 12-item Likert-type scale. Descriptive statistics were calculated, and comparisons between groups were performed using the Mann–Whitney U test and Chi-square test, where appropriate (α = 0.05).Results: Fourth-year students demonstrated significantly higher total knowledge and attitude scores than fifth-year students (p = 0.012). They also reported greater clinical exposure to maxillofacial cases and higher involvement in impression procedures (p = 0.018 and p = 0.036). Conversely, fifth-year students showed significantly higher self-reported knowledge regarding the operating principles of digital scanners (p = 0.002). Fourth-year students expressed stronger confidence in the accuracy and time-saving advantages of digital technologies (p < 0.001 and p = 0.001). Despite positive attitudes toward digitalization, awareness of specialized digital software such as craniofacial CAD and digital imaging platforms remained low among both groups.Conclusions: Although dental students demonstrate positive attitudes toward digital technologies in maxillofacial prosthetics, gaps remain between theoretical awareness and practical knowledge. Integrating structured digital workflow training into undergraduate dental curricula may help improve clinical competence and better prepare future clinicians for digitally driven maxillofacial rehabilitation.Keywords: Maxillofacial prosthetics, digital dentistry, dental education, dental students, digital workflow

  • Effect of Different Adhesive Systems on Shear Bond Strength Between Resin Cement and Titanium Abutment Surfaces

    by İrem Sözen Yanık, Dilara Sahin Hazir, Barış Güncü

    Background and Aim: This study evaluated the shearbond strength (SBS) of a universal resin cement to pre-milledtitanium surfaces using three different adhesive approaches.Materials and Methods: Forty-eight titanium specimens wereobtained from pre-milled titanium abutment blanks and equallydistributed into three experimental groups (n = 16) according tothe adhesive strategy: a dedicated metal primer (G-Multi Primer), atwo-bottle universal adhesive (Tokuyama Universal Bond II), and aone-bottle universal adhesive (Scotchbond Universal Plus). Prior tobonding, all surfaces were conditioned by airborne-particle abrasionusing 50 μm aluminum oxide particles. Resin cement cylinders wereprepared using a custom stainless-steel jig to ensure standardizeddimensions and positioning. The same self-adhesive dual-cure resincement (Maxcem Elite) was used for all specimens. Following 24hours of water storage at 37°C, immediate SBS was measured usinga universal testing machine at a crosshead speed of 1 mm/min.Fracture patterns after debonding were categorized as adhesive,cohesive, or mixed failures. Statistical evaluation included one-wayANOVA and Fisher’s Exact test at a significance level of 0.05.Results: Baseline surface roughness did not differ significantlyamong the experimental groups (p > 0.05). Airborne-particleabrasion increased the mean Ra value from 0.22 μm to 0.54 μm,with no significant differences among the groups after surfacetreatment (p > 0.05). Tokuyama Universal Bond II demonstratedthe highest mean SBS value (18.53 ± 2.45 MPa), followed byG-Multi Primer (17.32 ± 1.99 MPa) and Scotchbond UniversalPlus (16.67 ± 1.97 MPa). There were no significant differencesamong the adhesive systems (p = 0.057). Adhesive-type failurerepresented the most frequent fracture pattern across all groups,accounting for 62.5%–75% of failures. Cohesive fractures wereidentified only in the Tokuyama and G-Multi Primer groups.Conclusions: Both universal adhesives and dedicatedmetal primers demonstrated comparable immediate bondingperformance to titanium surfaces.

  • Advancements and Challenges in Dental Shade Matching: A Comprehensive Review of Visual and Instrumental Techniques

    by Şevval Takva, Dilara Sahin Hazir, Senay Canay

    Background:Achieving lifelike aesthetics in dental restorations depends heavily on accurate tooth color matching. However, conventional visual shade selection is often subjective and unreliable, prompting the integration of digital technologies in clinical workflows.Methods:This review examines current methods for tooth shade determination, including visual guides, colorimeters, spectrophotometers, hybrid systems, digital photography, and intraoral scanners. Each technique is evaluated in terms of accuracy, reproducibility, clinical applicability, and integration with digital dentistry systems.Results:Spectrophotometers consistently offer high precision and are less affected by environmental factors or observer bias, making them the gold standard for objective color determination. Intraoral scanners show increasing accuracy due to advancements in optical technology, although their performance varies across models. Digital photography, when standardized and calibrated, provides detailed visual documentation and aids in communication. Hybrid systems combine imaging and spectral analysis for improved consistency. Despite these advancements, no single method guarantees perfect results under all clinical conditions.Conclusions:The integration of digital technologies into shade selection has significantly enhanced objectivity and reproducibility in dental restorations. Nonetheless, combining multiple techniques—particularly visual inspection with spectrophotometric or scanner-based data—remains essential for accurate shade matching. Ongoing research and standardization efforts are needed to optimize clinical outcomes and improve reliability across devices.Keywords: Digital shade selection, spectrophotometer, intraoral scanner, colorimetry in dentistry, esthetic restorations, tooth color matching

  • Open Access

    Digital Assessment of Vertical and Horizontal Esthetic Alignment in Young Adults: A Cross‐Sectional Study

    by Irem Sozen Yanik, M. Baris Guncu, Dilara Sahin Hazir, Guliz Aktas, Ege Engin Deniz

    Objective: This study aimed to quantitatively evaluate the vertical and horizontal esthetic alignment parameters among young adults with high facial esthetic quality, thereby establishing reference benchmarks for natural facial symmetry and deviations. Methodology: A total of 220 participants aged 18–25 years were included following strict esthetic and dental inclusion criteria. Standardized frontal facial photographs were obtained and analyzed using digital design software. Vertical midline relationships (pupil–incisor, philtrum–incisor, pupil–philtrum) and horizontal planes (pupil–incisal, pupil–commissure, commissure–incisal) were measured. Vertical deviations were categorized into five groups, and horizontal relationships were classified as parallel or non‐parallel. Gender‐based differences were assessed using chi‐square analysis ( p < 0.05). Results: Reliability was excellent for vertical measurements (ICC = 0.93 intra‐observer, 95% CI: 0.90–0.96; ICC = 0.88 inter‐observer, 95% CI: 0.83–0.92) and substantial for horizontal plane assessments (Fleiss' kappa = 0.80; 95% CI: 0.72–0.87). Vertical midline alignment decreased progressively from the dental to the upper facial reference lines, with the highest coincidence observed in the philtrum–incisor relationship (48.6%) and the lowest in the pupil–philtrum alignment (23.4%). Horizontal plane parallelism showed a similar decreasing pattern toward upper facial structures. Gender comparisons revealed no significant differences in vertical midline alignment ( p > 0.05). Commissure–incisal parallelism was significantly higher in males ( p = 0.032), while other horizontal relationships showed no significant gender differences. Conclusions: Vertical and horizontal esthetic relationships follow characteristic patterns across facial levels, reflecting the natural asymmetry of the human face. Gender‐related differences were minimal and plane‐specific rather than generalized. Objective digital measurements provide reliable reference data for clinicians in establishing facially driven esthetic treatment plans. Clinical Significance: This study provides reference data for natural facial symmetry in young adults, highlighting that minor asymmetries are normal and often esthetically acceptable. Clinicians should focus on harmony with facial flow rather than perfect geometric symmetry. From a clinical perspective, objective digital assessment of vertical and horizontal reference relationships may assist clinicians in selecting appropriate esthetic reference planes during facially driven treatment planning. Rather than defining strict normative values, these findings support an individualized approach that respects natural facial variability.

  • Top Cited Papers
    Open Access

    Biomechanical behavior of titanium, cobalt-chromium, zirconia, and PEEK frameworks in implant-supported prostheses: a dynamic finite element analysis

    by Dilara Sahin Hazir, Irem Sozen Yanik, M. Baris Guncu, R. Senay Canay

    The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis. A 3D edentulous maxillary model was extracted from a computer tomography (CT) database. Bone level implants with conical connection designs were placed in the anterior (canine) and posterior (first molar) areas. Anterior implants were parallel, yet posterior implants were inclined distally by 30 degrees. According to the framework material, four groups were formed: cobalt-chromium (Co-Cr), zirconia (Zr), titanium (Ti), and polyether ether ketone (PEEK). For each framework material, twelve separate models of analysis were created by applying force in three different orientations. Dynamic forces were employed to replicate the chewing process. Principal and von Mises stresses were measured and evaluated. The PEEK framework exhibited the highest maximum von Mises stress values (372.55 MPa) on the abutment and the highest maximum principle stress values (59.27 MPa) in the cortical bone. The Co-Cr framework had the lowest minimum principle stress (3.98 MPa) in the trabecular bone. The displacements of the Co-Cr, Zr, Ti, and PEEK frameworks were 0.15 mm, 0.15 mm, 0.17 mm, and 0.35 mm, respectively. Frameworks having a greater Young's modulus are less susceptible to deformation.