State of the art: leadless ventricular pacing
Open Access
- 20 December 2019
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 57 (1) , 27-37
Abstract
Background: Cardiac pacing has been shown to improve quality of life and prognosis of patients with bradycardia for almost 60 years. The latest innovation in pacemaker therapy was miniaturization of generators to allow leadless pacing directly in the right ventricle. There is a long history and extensive experience of leadless ventricular pacing in Austria. However, no recommendations of national or international societies for indications and implantation of leadless opposed to transvenous pacing systems have been published so far. Results: A national expert panel of skilled implanters gives an overview on the two utilized leadless cardiac pacing systems and highlights clinical advantages as well as current knowledge of performance and complication rates of leadless pacing. Furthermore, a national consensus for Austria is presented, based on recent studies and current know-how, specifically including indications for leadless pacing, management of infection, suggestions for qualification, and training of the operators and technical standards. Conclusions: Leadless pacing systems can be implanted successfully with a low complication rate, if suggestions for indications and technical requirements are followed. Condensed An overview of the two utilized leadless cardiac pacing systems is given, specifically highlighting clinical advantages as well as current knowledge of performance and complication rates. Furthermore, a national consensus for Austria is presented, specifically including indications for leadless pacing, management of infection, and suggestions for qualification and technical standards.Keywords
Funding Information
- University of Innsbruck and Medical University of Innsbruck
This publication has 61 references indexed in Scilit:
- Tricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker LeadsThe American Journal of Cardiology, 2016
- Prevalence and predictor factors of severe venous obstruction after cardiovascular electronic device implantationEP Europace, 2015
- Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in DenmarkEuropean Heart Journal, 2013
- 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapyEuropean Heart Journal, 2013
- Incidence and predictors of pacemaker reprogramming: potential consequences for remote follow-upEP Europace, 2013
- 2012 ACCF/AHA/HRS Focused Update Incorporated Into the ACCF/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesJACC, 2013
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgradeEP Europace, 2007
- Severe Symptomatic Tricuspid Valve Regurgitation Due to Permanent Pacemaker or Implantable Cardioverter-Defibrillator LeadsJACC, 2005
- Lessons From the First Patient with an Implanted Pacemaker:Pacing and Clinical Electrophysiology, 2003