Quality assurance of VMAT on flattened and flattening filter‐free accelerators using a high spatial resolution detector
Open Access
- 11 April 2020
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (6) , 44-52
Abstract
Purpose: This study investigated the use of high spatial resolution solid‐state detectors (DUO and Octa) combined with an inclinometer for machine‐based quality assurance (QA) of Volumetric Modulated Arc Therapy (VMAT) with flattened and flattening filter‐free beams.Method: The proposed system was inserted in the accessory tray of the gantry head of a Varian 21iX Clinac and a Truebeam linear accelerator. Mutual dependence of the dose rate (DR) and gantry speed (GS) was assessed using the standard Varian customer acceptance plan (CAP). The multi‐leaf collimator (MLC) leaf speed was evaluated under static gantry conditions in directions parallel and orthogonal to gravity as well as under dynamic gantry conditions. Measurements were compared to machine log files.Results: DR and GS as a function of gantry angle were reconstructed using the DUO/inclinometer and in agreement to within 1% with the machine log files in the sectors of constant DR and GS. The MLC leaf speeds agreed with the nominal speeds and those extracted from the machine log files to within 0.03 cm s−1. The effect of gravity on the leaf motion was only observed when the leaves traveled faster than the nominal maximum velocity stated by the vendor. Under dynamic gantry conditions, MLC leaf speeds ranging between 0.33 and 1.42 cm s−1 were evaluated. Comparing the average MLC leaf speeds with the machine log files found differences between 0.9% and 5.7%, with the largest discrepancy occurring under conditions of fastest leaf velocity, lowest DR and lowest detector signal.Conclusions: The investigation on the use of solid‐state detectors in combination with an inclinometer has demonstrated the capability to provide efficient and independent verification of DR, GS, and MLC leaf speed during dynamic VMAT delivery. Good agreement with machine log files suggests the detector/inclinometer system is a useful tool for machine‐specific VMAT QA.Keywords
This publication has 34 references indexed in Scilit:
- Clinical experience transitioning from IMRT to VMAT for head and neck cancerMedical Dosimetry, 2013
- Measured vs simulated portal images for low MU fields on three accelerator types: Possible consequences for 2D portal dosimetryMedical Physics, 2012
- Implementation of phantom-less IMRT delivery verification using Varian DynaLog files and R/V outputPhysics in Medicine & Biology, 2012
- Comparison of Prostate IMRT and VMAT Biologically Optimised Treatment PlansMedical Dosimetry, 2011
- The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetryMedical Physics, 2011
- On the impact of dose rate variation upon RapidArc® implementation of volumetric modulated arc therapyMedical Physics, 2010
- Clinical Applications of Volumetric Modulated Arc TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Commissioning and Quality Assurance of RapidArc Radiotherapy Delivery SystemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Epid cine acquisition mode for in vivo dosimetry in dynamic arc radiation therapyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2008
- An extensive log‐file analysis of step‐and‐shoot intensity modulated radiation therapy segment delivery errorsMedical Physics, 2004