Improved perception of speech in noise and Mandarin tones with acoustic simulations of harmonic coding for cochlear implants
Authors:
- 1 November 2012
- journal article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 132 (5) , 3387-3398
Abstract
Harmonic and temporal fine structure (TFS) information are important cues for speech perception in noise and music perception. However, due to the inherently coarse spectral and temporal resolution in electric hearing, the question of how to deliver harmonic and TFS information to cochlear implant (CI) users remains unresolved. A harmonic-single-sideband-encoder [(HSSE); Nie et al. (2008). Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing; Lie et al., (2010). Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing] strategy has been proposed that explicitly tracks the harmonics in speech and transforms them into modulators conveying both amplitude modulation and fundamental frequency information. For unvoiced speech, HSSE transforms the TFS into a slowly varying yet still noise-like signal. To investigate its potential, four- and eight-channel vocoder simulations of HSSE and the continuous-interleaved-sampling (CIS) strategy were implemented, respectively. Using these vocoders, five normal-hearing subjects’ speech recognition performance was evaluated under different masking conditions; another five normal-hearing subjects’ Mandarin tone identification performance was also evaluated. Additionally, the neural discharge patterns evoked by HSSE- and CIS-encoded Mandarin tone stimuli were simulated using an auditory nerve model. All subjects scored significantly higher with HSSE than with CIS vocoders. The modeling analysis demonstrated that HSSE can convey temporal pitch cues better than CIS. Overall, the results suggest that HSSE is a promising strategy to enhance speech perception with CIs.Keywords
This publication has 38 references indexed in Scilit:
- Sensitivity of psychophysical measures to signal processor modifications in cochlear implant usersHearing Research, 2010
- Time-Frequency Coherent Modulation Filtering of Nonstationary SignalsIEEE Transactions on Signal Processing, 2009
- Lexical Tone Perception with HiResolution and HiResolution 120 Sound-Processing Strategies in Pediatric Mandarin-Speaking Cochlear Implant UsersEar & Hearing, 2009
- Effects of moderate cochlear hearing loss on the ability to benefit from temporal fine structure information in speechThe Journal of the Acoustical Society of America, 2008
- Speech recognition with varying numbers and types of competing talkers by normal-hearing, cochlear-implant, and implant simulation subjectsThe Journal of the Acoustical Society of America, 2008
- Listening to speech in the presence of other soundsPhilosophical Transactions of the Royal Society B: Biological Sciences, 2007
- Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implantsThe Journal of the Acoustical Society of America, 2001
- The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear-implant signal processors with 6–20 channelsThe Journal of the Acoustical Society of America, 1998
- A cochlear frequency-position function for several species—29 years laterThe Journal of the Acoustical Society of America, 1990
- Parametric coding of speech spectraThe Journal of the Acoustical Society of America, 1980