Kaibao Nie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kaibao Nie has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Jay T. Rubinstein
University of Washington Virginia Merrill Bloedel Hearing Research Center, Department of Otolaryngology-Head and Neck Surgery Box 357923, Seattle, Washington 98195
2 shared publicationsA. F. Fuchs
Department of Physiology and Biophysics and the Washington National Primate Research Center, University of Washington, Seattle, WA, USA
1 shared publicationC. R. S. Kaneko
Department of Physiology and Biophysics and the Washington National Primate Research Center, University of Washington, Seattle, WA, USA
1 shared publicationJ. O. Phillips
Department of Otolaryngology, Washington National Primate Research Center, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Seattle, USA
1 shared publicationJ. T. Rubinstein
Department of Otolaryngology, Department of Bioengineering, and Virginia Merrill Bloedel Hearing Research Center, University of Washington, Seattle, WA, USA
1 shared publicationJames O. Phillips
Department of Otolaryngology-Head and Neck Surgery, †Virginia Merrill Bloedel Hearing Research Center, ‡Washington National Primate Research Center, and §Department of Physiology and Biophysics, University of Washington, Seattle, Washington, U.S.A.
1 shared publication
Latest Publications
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (6) , 1685-1692
An Experimental Vestibular Neural Prosthesis: Design and Preliminary Results With Rhesus Monkeys Stimulated With Modulated Pulses
A vestibular neural prosthesis was designed on the basis of a cochlear implant for treatment of Meniere's disease and other vestibular disorders. Computer control software was developed to generate patterned pulse stimuli for exploring optimal parameters to activate the vestibular nerve. Two rhesus monkeys were implanted with the prototype vestibular prosthesis and they were behaviorally evaluated post implantation surgery. Horizontal and vertical eye movement responses to patterned electrical pulse stimulations were collected on both monkeys. Pulse amplitude modulated (PAM) and pulse rate modulated (PRM) trains were applied to the lateral canal of each implanted animal. Robust slow-phase nystagmus responses following the PAM or PRM modulation pattern were observed in both implanted monkeys in the direction consistent with the activation of the implanted canal. Both PAM and PRM pulse trains can elicit a significant amount of in-phase modulated eye velocity changes and they could potentially be used for efficiently coding head rotational signals in future vestibular neural prostheses.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (6) , 1685-1692
An Experimental Vestibular Neural Prosthesis: Design and Preliminary Results With Rhesus Monkeys Stimulated With Modulated Pulses
A vestibular neural prosthesis was designed on the basis of a cochlear implant for treatment of Meniere's disease and other vestibular disorders. Computer control software was developed to generate patterned pulse stimuli for exploring optimal parameters to activate the vestibular nerve. Two rhesus monkeys were implanted with the prototype vestibular prosthesis and they were behaviorally evaluated post implantation surgery. Horizontal and vertical eye movement responses to patterned electrical pulse stimulations were collected on both monkeys. Pulse amplitude modulated (PAM) and pulse rate modulated (PRM) trains were applied to the lateral canal of each implanted animal. Robust slow-phase nystagmus responses following the PAM or PRM modulation pattern were observed in both implanted monkeys in the direction consistent with the activation of the implanted canal. Both PAM and PRM pulse trains can elicit a significant amount of in-phase modulated eye velocity changes and they could potentially be used for efficiently coding head rotational signals in future vestibular neural prostheses.
- 1 November 2012
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 132 (5) , 3387-3398
Improved perception of speech in noise and Mandarin tones with acoustic simulations of harmonic coding for cochlear implants
Harmonic and temporal fine structure (TFS) information are important cues for speech perception in noise and music perception. However, due to the inherently coarse spectral and temporal resolution in electric hearing, the question of how to deliver harmonic and TFS information to cochlear implant (CI) users remains unresolved. A harmonic-single-sideband-encoder [(HSSE); Nie et al. (2008). Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing; Lie et al., (2010). Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing] strategy has been proposed that explicitly tracks the harmonics in speech and transforms them into modulators conveying both amplitude modulation and fundamental frequency information. For unvoiced speech, HSSE transforms the TFS into a slowly varying yet still noise-like signal. To investigate its potential, four- and eight-channel vocoder simulations of HSSE and the continuous-interleaved-sampling (CIS) strategy were implemented, respectively. Using these vocoders, five normal-hearing subjects’ speech recognition performance was evaluated under different masking conditions; another five normal-hearing subjects’ Mandarin tone identification performance was also evaluated. Additionally, the neural discharge patterns evoked by HSSE- and CIS-encoded Mandarin tone stimuli were simulated using an auditory nerve model. All subjects scored significantly higher with HSSE than with CIS vocoders. The modeling analysis demonstrated that HSSE can convey temporal pitch cues better than CIS. Overall, the results suggest that HSSE is a promising strategy to enhance speech perception with CIs.
- 1 November 2012
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 132 (5) , 3387-3398
Improved perception of speech in noise and Mandarin tones with acoustic simulations of harmonic coding for cochlear implants
Harmonic and temporal fine structure (TFS) information are important cues for speech perception in noise and music perception. However, due to the inherently coarse spectral and temporal resolution in electric hearing, the question of how to deliver harmonic and TFS information to cochlear implant (CI) users remains unresolved. A harmonic-single-sideband-encoder [(HSSE); Nie et al. (2008). Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing; Lie et al., (2010). Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing] strategy has been proposed that explicitly tracks the harmonics in speech and transforms them into modulators conveying both amplitude modulation and fundamental frequency information. For unvoiced speech, HSSE transforms the TFS into a slowly varying yet still noise-like signal. To investigate its potential, four- and eight-channel vocoder simulations of HSSE and the continuous-interleaved-sampling (CIS) strategy were implemented, respectively. Using these vocoders, five normal-hearing subjects’ speech recognition performance was evaluated under different masking conditions; another five normal-hearing subjects’ Mandarin tone identification performance was also evaluated. Additionally, the neural discharge patterns evoked by HSSE- and CIS-encoded Mandarin tone stimuli were simulated using an auditory nerve model. All subjects scored significantly higher with HSSE than with CIS vocoders. The modeling analysis demonstrated that HSSE can convey temporal pitch cues better than CIS. Overall, the results suggest that HSSE is a promising strategy to enhance speech perception with CIs.
- 1 January 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (1) , 88-97
Characterization of the Electrically Evoked Compound Action Potential of the Vestibular Nerve
Objective: We recorded intraoperative and postoperative electrically evoked compound action potentials (ECAPs) in rhesus monkeys implanted with a vestibular neurostimulator. The objectives were to correlate the generation of slow-phase nystagmus or eye twitches induced by electrical stimulation of the implanted semicircular canal with the presence or absence of the vestibular ECAP responses and to assess the effectiveness of ECAP monitoring during surgery to guide surgical insertion of electrode arrays into the canals. Design: Four rhesus monkeys (a total of 7 canals) were implanted with a vestibular neurostimulator modified from the Nucleus Freedom cochlear implant. ECAP recordings were obtained during surgery or at various intervals after surgery using the Neural Response Telemetry feature of the clinical Custom Sound EP software. Eye movements during electrical stimulation of individual canals were recorded with a scleral search coil system in the same animals. Results: Measurable vestibular ECAPs were observed intraoperatively or postoperatively in 3 implanted animals. Robust and sustained ECAPs were obtained in 3 monkeys at the test intervals of 0, 7, or greater than 100 days after implantation surgery. In all 3 animals, stimulation with electrical pulse trains produced measurable eye movements in a direction consistent with the vestibulo-ocular reflex from the implanted semicircular canal. In contrast, electrically evoked eye movements could not be measured in 3 of the 7 implanted canals, none of which produced distinct vestibular ECAPs. In 2 animals, ECAP waveforms were systematically monitored during surgery, and the procedure proved crucial to the success of vestibular implantation. Conclusion: Vestibular ECAPs exhibit similar morphology and growth characteristics to cochlear ECAPs from human cochlear implant patients. The ECAP measure is well correlated with the functional activation of eye movements by electrical stimulation after implantation surgery. The intraoperative ECAP recording technique is an efficient tool to guide the placement of electrode array into the semicircular canals.
- 1 January 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (1) , 88-97
Characterization of the Electrically Evoked Compound Action Potential of the Vestibular Nerve
Objective: We recorded intraoperative and postoperative electrically evoked compound action potentials (ECAPs) in rhesus monkeys implanted with a vestibular neurostimulator. The objectives were to correlate the generation of slow-phase nystagmus or eye twitches induced by electrical stimulation of the implanted semicircular canal with the presence or absence of the vestibular ECAP responses and to assess the effectiveness of ECAP monitoring during surgery to guide surgical insertion of electrode arrays into the canals. Design: Four rhesus monkeys (a total of 7 canals) were implanted with a vestibular neurostimulator modified from the Nucleus Freedom cochlear implant. ECAP recordings were obtained during surgery or at various intervals after surgery using the Neural Response Telemetry feature of the clinical Custom Sound EP software. Eye movements during electrical stimulation of individual canals were recorded with a scleral search coil system in the same animals. Results: Measurable vestibular ECAPs were observed intraoperatively or postoperatively in 3 implanted animals. Robust and sustained ECAPs were obtained in 3 monkeys at the test intervals of 0, 7, or greater than 100 days after implantation surgery. In all 3 animals, stimulation with electrical pulse trains produced measurable eye movements in a direction consistent with the vestibulo-ocular reflex from the implanted semicircular canal. In contrast, electrically evoked eye movements could not be measured in 3 of the 7 implanted canals, none of which produced distinct vestibular ECAPs. In 2 animals, ECAP waveforms were systematically monitored during surgery, and the procedure proved crucial to the success of vestibular implantation. Conclusion: Vestibular ECAPs exhibit similar morphology and growth characteristics to cochlear ECAPs from human cochlear implant patients. The ECAP measure is well correlated with the functional activation of eye movements by electrical stimulation after implantation surgery. The intraoperative ECAP recording technique is an efficient tool to guide the placement of electrode array into the semicircular canals.