Detection of RF unsafe devices using a parallel transmission MR system
Open Access
- 30 November 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (5) , 1440-1449
Abstract
Purpose: The permanent presence of devices (pacemakers) inside a patient, or the need to use other devices (catheters), for diagnosis and treatment, usually represents a contraindication for a magnetic resonance examination. To help overcome this problem, a novel and noninvasive magnetic resonance system‐based concept is proposed to detect potentially unsafe radio frequency (RF) conditions of such devices to ensure patient safety.Methods: This concept makes use of parallel transmit technology by monitoring currents in individual RF transmit coil elements during RF transmission using suitable current sensors. For interventional devices, current changes can be directly measured, whereas for implanted devices, the use of reference signals is proposed, which cannot be measured in the patient.Results: Coupling of unsafe devices to transmit coils led to detectable current changes in the elements because of energy absorption into the device. The concept was successfully tested on interventional and implantable devices and turned out to be so sensitive that even very weak RF coupling to these devices was detectable.Conclusion: In this study, basic feasibility to detect RF unsafe conditions was successfully demonstrated. In the future, RF patient safety may be improved in the presence of implanted devices, as well as during interventions using this concept. Magn Reson Med 70:1440–1449, 2013.Keywords
This publication has 33 references indexed in Scilit:
- System and SAR characterization in parallel RF transmissionMagnetic Resonance in Medicine, 2011
- A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)European Heart Journal, 2011
- Comments on “Ensuring safety of implanted devices under MRI using reversed polarization”Magnetic Resonance in Medicine, 2011
- Ensuring safety of implanted devices under MRI using reversed RF polarizationMagnetic Resonance in Medicine, 2010
- Measuring RF‐induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leadsMagnetic Resonance in Medicine, 2009
- Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study designTrials, 2008
- Overcoming high-field RF problems with non-magnetic Cartesian feedback transceiversMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- In vivo heating of pacemaker leads during magnetic resonance imagingEuropean Heart Journal, 2004
- The NMR multi-transmit phased array: a Cartesian feedback approachJournal of Magnetic Resonance, 2004
- Effects of magnetic resonance imaging on cardiac pacemakers and electrodesAmerican Heart Journal, 1997