Ingmar Graesslin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ingmar Graesslin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Kay Nehrke
Department Tomographic Imaging Systems, Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany
3 shared publicationsPeter Vernickel
Department Tomographic Imaging Systems, Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany
3 shared publicationsGiel Mens
MR Business Innovation Unit, Philips Healthcare, Best, The Netherlands
2 shared publicationsPaul Harvey
MR Business Innovation Unit, Philips Healthcare, Best, The Netherlands
2 shared publicationsPeter Börnert
Department Tomographic Imaging Systems, Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany
2 shared publicationsChristian Findeklee
Philips Research Europe, Department of Tomographic Imaging systems, Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 22 August 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (2) , 589-598
Comprehensive RF safety concept for parallel transmission MR
Purpose: The goal of this study is to increase patient safety in parallel transmission (pTx) MRI systems. A major concern in these systems is radiofrequency‐induced tissue heating, which can be avoided by specific absorption rate (SAR) prediction and SAR monitoring before and during the scan.Methods: In this novel comprehensive safety concept, the SAR is predicted prior to the scan based on precalculated fields obtained from electromagnetic simulations on different body models. The radiofrequency fields and the global and local SAR are supervised in real time during the scan. This concept is integrated into a 3 T pTx MR scanner and validated experimentally.Results: Phantom and in vivo experiments successfully validated the basic feasibility of the real‐time SAR supervision concept. Supervising the SAR minimizes SAR overestimation. Monitoring the radiofrequency fields allows the detection of unsafe radiofrequency situations for the patient, which a SAR supervision system alone cannot detect.Conclusion: This study demonstrates safe scanning in a pTx system. This new safety concept is also applicable for field strengths above 3 T and represents an important step toward safe operation of pTx systems. Magn Reson Med 74:589–598, 2015.
- 22 August 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (2) , 589-598
Open AccessComprehensive RF safety concept for parallel transmission MR
Purpose: The goal of this study is to increase patient safety in parallel transmission (pTx) MRI systems. A major concern in these systems is radiofrequency‐induced tissue heating, which can be avoided by specific absorption rate (SAR) prediction and SAR monitoring before and during the scan.Methods: In this novel comprehensive safety concept, the SAR is predicted prior to the scan based on precalculated fields obtained from electromagnetic simulations on different body models. The radiofrequency fields and the global and local SAR are supervised in real time during the scan. This concept is integrated into a 3 T pTx MR scanner and validated experimentally.Results: Phantom and in vivo experiments successfully validated the basic feasibility of the real‐time SAR supervision concept. Supervising the SAR minimizes SAR overestimation. Monitoring the radiofrequency fields allows the detection of unsafe radiofrequency situations for the patient, which a SAR supervision system alone cannot detect.Conclusion: This study demonstrates safe scanning in a pTx system. This new safety concept is also applicable for field strengths above 3 T and represents an important step toward safe operation of pTx systems. Magn Reson Med 74:589–598, 2015.
- Open Access
- 30 November 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (5) , 1440-1449
Detection of RF unsafe devices using a parallel transmission MR system
Purpose: The permanent presence of devices (pacemakers) inside a patient, or the need to use other devices (catheters), for diagnosis and treatment, usually represents a contraindication for a magnetic resonance examination. To help overcome this problem, a novel and noninvasive magnetic resonance system‐based concept is proposed to detect potentially unsafe radio frequency (RF) conditions of such devices to ensure patient safety.Methods: This concept makes use of parallel transmit technology by monitoring currents in individual RF transmit coil elements during RF transmission using suitable current sensors. For interventional devices, current changes can be directly measured, whereas for implanted devices, the use of reference signals is proposed, which cannot be measured in the patient.Results: Coupling of unsafe devices to transmit coils led to detectable current changes in the elements because of energy absorption into the device. The concept was successfully tested on interventional and implantable devices and turned out to be so sensitive that even very weak RF coupling to these devices was detectable.Conclusion: In this study, basic feasibility to detect RF unsafe conditions was successfully demonstrated. In the future, RF patient safety may be improved in the presence of implanted devices, as well as during interventions using this concept. Magn Reson Med 70:1440–1449, 2013.
- 30 November 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (5) , 1440-1449
Open AccessDetection of RF unsafe devices using a parallel transmission MR system
Purpose: The permanent presence of devices (pacemakers) inside a patient, or the need to use other devices (catheters), for diagnosis and treatment, usually represents a contraindication for a magnetic resonance examination. To help overcome this problem, a novel and noninvasive magnetic resonance system‐based concept is proposed to detect potentially unsafe radio frequency (RF) conditions of such devices to ensure patient safety.Methods: This concept makes use of parallel transmit technology by monitoring currents in individual RF transmit coil elements during RF transmission using suitable current sensors. For interventional devices, current changes can be directly measured, whereas for implanted devices, the use of reference signals is proposed, which cannot be measured in the patient.Results: Coupling of unsafe devices to transmit coils led to detectable current changes in the elements because of energy absorption into the device. The concept was successfully tested on interventional and implantable devices and turned out to be so sensitive that even very weak RF coupling to these devices was detectable.Conclusion: In this study, basic feasibility to detect RF unsafe conditions was successfully demonstrated. In the future, RF patient safety may be improved in the presence of implanted devices, as well as during interventions using this concept. Magn Reson Med 70:1440–1449, 2013.
- Open Access
- 9 January 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (5) , 1664-1674
A specific absorption rate prediction concept for parallel transmission MR
The specific absorption rate (SAR) is a limiting factor in high‐field MR. SAR estimation is typically performed by numerical simulations using generic human body models. However, SAR concepts for single‐channel radiofrequency transmission cannot be directly applied to multichannel systems. In this study, a novel and comprehensive SAR prediction concept for parallel radiofrequency transmission MRI is presented, based on precalculated magnetic and electric fields obtained from electromagnetic simulations of numerical body models. The application of so‐called Q‐matrices and further computational optimizations allow for a real‐time estimation of the SAR prior to scanning. This SAR estimation method was fully integrated into an eight‐channel whole body MRI system, and it facilitated the selection of different body models and body positions. Experimental validation of the global SAR in phantoms demonstrated a good qualitative and quantitative agreement with the predictions. An initial in vivo validation showed good qualitative agreement between simulated and measured amplitude of (excitation) radiofrequency field. The feasibility and practicability of this SAR prediction concept was shown paving the way for safe parallel radiofrequency transmission in high‐field MR. Magn Reson Med, 2012.
- 9 January 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (5) , 1664-1674
Open AccessA specific absorption rate prediction concept for parallel transmission MR
The specific absorption rate (SAR) is a limiting factor in high‐field MR. SAR estimation is typically performed by numerical simulations using generic human body models. However, SAR concepts for single‐channel radiofrequency transmission cannot be directly applied to multichannel systems. In this study, a novel and comprehensive SAR prediction concept for parallel radiofrequency transmission MRI is presented, based on precalculated magnetic and electric fields obtained from electromagnetic simulations of numerical body models. The application of so‐called Q‐matrices and further computational optimizations allow for a real‐time estimation of the SAR prior to scanning. This SAR estimation method was fully integrated into an eight‐channel whole body MRI system, and it facilitated the selection of different body models and body positions. Experimental validation of the global SAR in phantoms demonstrated a good qualitative and quantitative agreement with the predictions. An initial in vivo validation showed good qualitative agreement between simulated and measured amplitude of (excitation) radiofrequency field. The feasibility and practicability of this SAR prediction concept was shown paving the way for safe parallel radiofrequency transmission in high‐field MR. Magn Reson Med, 2012.
- Open Access
- 16 November 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (2) , 350-357
Specific absorption rate reduction in parallel transmission byk-space adaptive radiofrequency pulse design
The specific absorption rate (SAR) is an important safety criterion, limiting many MR protocols with respect to the achievable contrast and scan duration. Parallel transmission enables control of the radiofrequency field in space and time and hence allows for SAR management. However, a trade-off exists between radiofrequency pulse performance and SAR reduction. To overcome this problem, in this work, parallel transmit radiofrequency pulses are adapted to the position in sampling k-space. In the central k-space, highly homogeneous but SAR-intensive radiofrequency shim settings are used to achieve optimal performance and contrast. In the outer k-space, the homogeneity requirement is relaxed to reduce the average SAR of the scan. The approach was experimentally verified on phantoms and volunteers using field echo and spin echo sequences. A reduction of the SAR by 25–50% was achieved without compromising image quality. Magn Reson Med, 2011.
- 16 November 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (2) , 350-357
Open AccessSpecific absorption rate reduction in parallel transmission byk-space adaptive radiofrequency pulse design
The specific absorption rate (SAR) is an important safety criterion, limiting many MR protocols with respect to the achievable contrast and scan duration. Parallel transmission enables control of the radiofrequency field in space and time and hence allows for SAR management. However, a trade-off exists between radiofrequency pulse performance and SAR reduction. To overcome this problem, in this work, parallel transmit radiofrequency pulses are adapted to the position in sampling k-space. In the central k-space, highly homogeneous but SAR-intensive radiofrequency shim settings are used to achieve optimal performance and contrast. In the outer k-space, the homogeneity requirement is relaxed to reduce the average SAR of the scan. The approach was experimentally verified on phantoms and volunteers using field echo and spin echo sequences. A reduction of the SAR by 25–50% was achieved without compromising image quality. Magn Reson Med, 2011.