Application ofgate‐controlledseries capacitor to mitigate subsynchronous resonance in a thermal generation plant connected to aseries‐compensatedtransmission network
- 13 October 2020
- journal article
- research article
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (12)
Abstract
This paper demonstrates the functionality and control of the gate‐controlled series capacitor (GCSC), a new FACTS device composing a pair of antiparallel GTOs in parallel with a fixed capacitor, to mitigate subsynchronous resonance (SSR) in a thermal generation plant connected to a series compensated transmission line. Firstly, by the use of both small‐signal stability analysis and time‐domain simulation, it is revealed that the studied system compensated by the series fixed capacitor is potentially unstable due to the first torsional mode. Then, in order to take benefits of series compensation without the risk of SSR, the fixed capacitor is replaced by GCSC. The capability and effectiveness of the GCSC to damp SSR are validated using modal analysis and time‐domain simulation. Furthermore, GCSC is used in conjunction with a fixed series capacitor to minimize the overall cost of compensation. For this purpose, unlike previous studies, a linear controller is used to stabilize the system. In this study, the IEEE First Benchmark Model is considered as a case study, and MATLAB/Simulink is used as a tool for modeling and design of the control system. Also, time‐domain simulations are done using PSCAD/EMTDC.Keywords
This publication has 22 references indexed in Scilit:
- Comprehensive review of gate‐controlled series capacitor and applications in electrical systemsIET Generation, Transmission & Distribution, 2017
- Modeling and Control of Gate-Controlled Series Capacitor Interfaced With a DFIG-Based Wind FarmIEEE Transactions on Industrial Electronics, 2014
- Application of UPFC to Enhancing Oscillatory Response of Series-Compensated Wind Farm IntegrationsIEEE Transactions on Smart Grid, 2014
- Sub-synchronous resonance mitigation in wind farms using gate-controlled series capacitor2013
- Damping of sub-synchronous resonance and low-frequency power oscillation in a series-compensated transmission line using gate-controlled series capacitorElectric Power Systems Research, 2011
- Design and Performance Evaluation of Subsynchronous Damping Controller With STATCOMIEEE Transactions on Power Delivery, 2006
- Subsynchronous resonance damping control of thyristor-controlled series capacitorIEEE Transactions on Power Delivery, 2003
- Impact of TCSC control methodologies on subsynchronous oscillationsIEEE Transactions on Power Delivery, 2003
- Damping subsynchronous resonance using modal-control NGH SSR damping scheme. I. Single-machine study2002
- Modulation and SSR tests performed on the BPA 500 kV thyristor controlled series capacitor unit at Slatt substationIEEE Transactions on Power Systems, 1996