Analysis of the Effect of Common Disturbances on the Safety of a Wearable Tremor Suppression Device
- 26 February 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2846-2853
Abstract
The advent of wearable technology has enabled a large number of externally worn mechatronic devices to be developed and tested on people with movement disorders. The complexity of these disorders and the variety of conditions across different patients have resulted in a pressing demand for the incorporation of intelligent control systems, especially for a wearable tremor suppression device (WTSD) that can suppress tremor without impeding the user's voluntary motion. Several devices have been developed to reduce tremor; however, the evaluations of these devices have only been done in a controlled lab setting, while the functionality and ability to avoid user injury under the effect of disturbances during daily use have not been investigated. In this study, the performance of a WTSD was tested with several commonly used tremor suppression control systems, i.e., Weight-frequency Fourier Linear Combiner (WFLC), Bandlimited Multiple Fourier Linear Combiner, and enhanced High-order WFLC-based Kalman Filter, on a bench-top tremor simulator. These systems were also tested under the influence of three simulated disturbances that are commonly seen in real life, i.e., data mutation, sensor drift, and measurement loss. The experimental evaluation showed that none of these systems are safe under the disturbances. The tremor power suppression ratio (67.8%-94.2%) of the WTSD was not significantly lowered by the disturbances; however, the error when tracking voluntary motion significantly increased by 8.8 ° -93.6 ° , which may present a safety hazard to the users. The results of this study emphasize the importance of integrating safety measures into intelligent WTSDs.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- Canadian Institutes of Health Research
- Collaborative Health Research Projects (# 396234)
- Canada Foundation for Innovation
- Ontario Research Foundation
- Ontario Ministry of Economic Development, Trade and Employment
- Ontario Ministry of Research and Innovation
- Peter C. Maurice Research Fellowship in Biomedical Engineering
This publication has 24 references indexed in Scilit:
- Adaptive sliding bandlimited multiple fourier linear combiner for estimation of pathological tremorBiomedical Signal Processing and Control, 2014
- Diagnosis and Treatment of Common Forms of TremorSeminars in Neurology, 2011
- Real-Time Estimation of Pathological Tremor Parameters from Gyroscope DataSensors, 2010
- Double adaptive bandlimited multiple Fourier linear combiner for real-time estimation/filtering of physiological tremorBiomedical Signal Processing and Control, 2010
- Mechanical suppression of essential tremorThe Cerebellum, 2007
- Prevalence of movement disorders in men and women aged 50–89 years (Bruneck Study cohort): a population-based studyThe Lancet Neurology, 2005
- Self-Initiated Versus Externally Cued Reaction Times in Parkinson's DiseaseJournal of Clinical and Experimental Neuropsychology, 2002
- Adaptive cancelling of physiological tremor for improved precision in microsurgeryIEEE Transactions on Biomedical Engineering, 1998
- An adaptive estimation of periodic signals using a Fourier linear combinerIEEE Transactions on Signal Processing, 1994
- THE EFFECT OF MECHANICAL IMPEDANCE ON ABNORMAL INTENTION TREMOR1981