Anas Ibrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anas Ibrahim has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ana Luisa Trejos
Western University
4 shared publications - Michael D. Naish
Department of Mechanical and Materials Engineering, ECE, and BME, Western University, London, ON, Canada
4 shared publications - Yue Zhou
School of Biomedical Engineering (BME), Western University, London, ON, Canada
4 shared publications Mary E. Jenkins
Movement Disorders Program, Clinical Neurological Sciences, Western University, London, ON, Canada
3 shared publicationsKenneth G. Hardy
Ivey Business School, Western University, Canada
1 shared publication- Mary E. Jenkins
Movement Disorders Program, Clinical Neurological Sciences, Western University, London, ON, Canada
1 shared publication
Latest Publications
- Open Access
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2856-2865
Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device
The side effects and complications of traditional treatments for treating pathological tremor have led to a growing research interest in wearable tremor suppression devices (WTSDs) as an alternative approach. Similar to how the human brain coordinates the function of the human system, a tremor estimator determines how a WTSD functions. Although many tremor estimation algorithms have been developed and validated, whether they can be implemented on a cost-effective embedded system has not been studied; furthermore, their effectiveness on tremor signals with multiple harmonics has not been investigated. Therefore, in this study, four tremor estimators were implemented, evaluated, and compared: Weighted-frequency Fourier Linear Combiner (WFLC), WFLC-based Kalman Filter (WFLC-KF), Band-limited Multiple FLC, and enhanced High-order WFLC-KF (eHWFLC-KF). This study aimed to evaluate the performance of each algorithm on a bench-top tremor suppression system with 18 recorded tremor motion datasets; and compare the performance of each estimator. The experimental evaluation showed that the eHWFLC-KF-based WTSD achieved the best performance when suppressing tremor with an average of 89.3% reduction in tremor power, and an average error when tracking voluntary motion of 6.6°/s. Statistical analysis indicated that the eHWFLC-KF-based WTSD is able to reduce the power of tremor better than the WFLC and WFLC-KF, and the BMFLC-based WTSD is better than the WFLC. The performance when tracking voluntary motion is similar among all systems. This study has proven the feasibility of implementing various tremor estimators in a cost-effective embedded system, and provided a real-time performance assessment of four tremor estimators.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2856-2865
Open AccessReal-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device
The side effects and complications of traditional treatments for treating pathological tremor have led to a growing research interest in wearable tremor suppression devices (WTSDs) as an alternative approach. Similar to how the human brain coordinates the function of the human system, a tremor estimator determines how a WTSD functions. Although many tremor estimation algorithms have been developed and validated, whether they can be implemented on a cost-effective embedded system has not been studied; furthermore, their effectiveness on tremor signals with multiple harmonics has not been investigated. Therefore, in this study, four tremor estimators were implemented, evaluated, and compared: Weighted-frequency Fourier Linear Combiner (WFLC), WFLC-based Kalman Filter (WFLC-KF), Band-limited Multiple FLC, and enhanced High-order WFLC-KF (eHWFLC-KF). This study aimed to evaluate the performance of each algorithm on a bench-top tremor suppression system with 18 recorded tremor motion datasets; and compare the performance of each estimator. The experimental evaluation showed that the eHWFLC-KF-based WTSD achieved the best performance when suppressing tremor with an average of 89.3% reduction in tremor power, and an average error when tracking voluntary motion of 6.6°/s. Statistical analysis indicated that the eHWFLC-KF-based WTSD is able to reduce the power of tremor better than the WFLC and WFLC-KF, and the BMFLC-based WTSD is better than the WFLC. The performance when tracking voluntary motion is similar among all systems. This study has proven the feasibility of implementing various tremor estimators in a cost-effective embedded system, and provided a real-time performance assessment of four tremor estimators.
- Open Access
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1413-1423
Real-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Wearable tremor suppression devices (WTSD) have been considered as a viable solution to manage parkinsonian tremor. WTSDs showed their ability to improve the quality of life of individuals suffering from parkinsonian tremor, by helping them to perform activities of daily living (ADL). Since parkinsonian tremor has been shown to be nonstationary, nonlinear, and stochastic in nature, the performance of the tremor models used by WTSDs is affected by their inability to adapt to the nonlinear behaviour of tremor. Another drawback that the models have is their limitation to estimate or predict one step ahead, which introduces delay when used in real time with WTSDs, which compromises performance. To address these issues, this work proposes a deep neural network model that learns the correlations and nonlinearities of tremor and voluntary motion, and is capable of multi-step prediction with minimal delay. A generalized model that is task and user-independent is presented. The model achieved an average estimation percentage accuracy of 99.2%. The average future voluntary motion prediction percentage accuracy with 10, 20, 50, and 100 steps ahead was 97.0%, 94.0%, 91.6%, and 89.9%, respectively, with prediction time as low as 1.5 ms for 100 steps ahead. The proposed model also achieved an average of 93.8% ± 1.5% in tremor reduction when it was tested in an experimental setup in real time. The tremor reduction showed an improvement of 25% over the Weighted Fourier Linear Combiner (WFLC), an estimator commonly used with WTSDs.
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1413-1423
Open AccessReal-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Wearable tremor suppression devices (WTSD) have been considered as a viable solution to manage parkinsonian tremor. WTSDs showed their ability to improve the quality of life of individuals suffering from parkinsonian tremor, by helping them to perform activities of daily living (ADL). Since parkinsonian tremor has been shown to be nonstationary, nonlinear, and stochastic in nature, the performance of the tremor models used by WTSDs is affected by their inability to adapt to the nonlinear behaviour of tremor. Another drawback that the models have is their limitation to estimate or predict one step ahead, which introduces delay when used in real time with WTSDs, which compromises performance. To address these issues, this work proposes a deep neural network model that learns the correlations and nonlinearities of tremor and voluntary motion, and is capable of multi-step prediction with minimal delay. A generalized model that is task and user-independent is presented. The model achieved an average estimation percentage accuracy of 99.2%. The average future voluntary motion prediction percentage accuracy with 10, 20, 50, and 100 steps ahead was 97.0%, 94.0%, 91.6%, and 89.9%, respectively, with prediction time as low as 1.5 ms for 100 steps ahead. The proposed model also achieved an average of 93.8% ± 1.5% in tremor reduction when it was tested in an experimental setup in real time. The tremor reduction showed an improvement of 25% over the Weighted Fourier Linear Combiner (WFLC), an estimator commonly used with WTSDs.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2846-2857
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Objective: Approximately 25% of individualsliving with parkinsonian tremor do not respond to traditional treatments. Wearable tremor suppression devices (WTSD) provide an alternative approach, however, tremor in the fingers has not been given as much attention as tremor in the elbow and the wrist. Therefore, the objective of this study is to design a wearable tremor suppression glove that can suppress tremor simultaneously, but independently, in multiple hand joints without restricting the user's voluntary motion. Methods: A WTSD was designed for managing tremor in the index finger metacarpophalangeal (MCP) joint, thumb MCP joint, and the wrist. The prototype was tested and assessed on a participant living with parkinsonian tremor. Results: The experimental evaluation showed an overall suppression of 73.1%, 80.7%, and 85.5% in resting tremor, 70.2%, 79.5%, and 81% in postural tremor, and 60.0%, 58.7%, and 65.0% in kinetic tremor in the index finger MCP joint, the thumb MCP joint, and the wrist, respectively. Conclusion: This first assessment of a WTSD for people living with Parkinson's disease provides confirmation of the feasibility of the approach. The next step requires a comprehensive validation on a broader population in order to evaluate the performance of the WTSD. Significance: This study demonstrates the feasibility of using a WTSD to manage hand and finger tremor. The device enriches the field of upper-limb tremor management, as the first WTSD for multiple joints of the hand.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2846-2857
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Objective: Approximately 25% of individualsliving with parkinsonian tremor do not respond to traditional treatments. Wearable tremor suppression devices (WTSD) provide an alternative approach, however, tremor in the fingers has not been given as much attention as tremor in the elbow and the wrist. Therefore, the objective of this study is to design a wearable tremor suppression glove that can suppress tremor simultaneously, but independently, in multiple hand joints without restricting the user's voluntary motion. Methods: A WTSD was designed for managing tremor in the index finger metacarpophalangeal (MCP) joint, thumb MCP joint, and the wrist. The prototype was tested and assessed on a participant living with parkinsonian tremor. Results: The experimental evaluation showed an overall suppression of 73.1%, 80.7%, and 85.5% in resting tremor, 70.2%, 79.5%, and 81% in postural tremor, and 60.0%, 58.7%, and 65.0% in kinetic tremor in the index finger MCP joint, the thumb MCP joint, and the wrist, respectively. Conclusion: This first assessment of a WTSD for people living with Parkinson's disease provides confirmation of the feasibility of the approach. The next step requires a comprehensive validation on a broader population in order to evaluate the performance of the WTSD. Significance: This study demonstrates the feasibility of using a WTSD to manage hand and finger tremor. The device enriches the field of upper-limb tremor management, as the first WTSD for multiple joints of the hand.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2846-2853
Analysis of the Effect of Common Disturbances on the Safety of a Wearable Tremor Suppression Device
The advent of wearable technology has enabled a large number of externally worn mechatronic devices to be developed and tested on people with movement disorders. The complexity of these disorders and the variety of conditions across different patients have resulted in a pressing demand for the incorporation of intelligent control systems, especially for a wearable tremor suppression device (WTSD) that can suppress tremor without impeding the user's voluntary motion. Several devices have been developed to reduce tremor; however, the evaluations of these devices have only been done in a controlled lab setting, while the functionality and ability to avoid user injury under the effect of disturbances during daily use have not been investigated. In this study, the performance of a WTSD was tested with several commonly used tremor suppression control systems, i.e., Weight-frequency Fourier Linear Combiner (WFLC), Bandlimited Multiple Fourier Linear Combiner, and enhanced High-order WFLC-based Kalman Filter, on a bench-top tremor simulator. These systems were also tested under the influence of three simulated disturbances that are commonly seen in real life, i.e., data mutation, sensor drift, and measurement loss. The experimental evaluation showed that none of these systems are safe under the disturbances. The tremor power suppression ratio (67.8%-94.2%) of the WTSD was not significantly lowered by the disturbances; however, the error when tracking voluntary motion significantly increased by 8.8 ° -93.6 ° , which may present a safety hazard to the users. The results of this study emphasize the importance of integrating safety measures into intelligent WTSDs.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2846-2853
Analysis of the Effect of Common Disturbances on the Safety of a Wearable Tremor Suppression Device
The advent of wearable technology has enabled a large number of externally worn mechatronic devices to be developed and tested on people with movement disorders. The complexity of these disorders and the variety of conditions across different patients have resulted in a pressing demand for the incorporation of intelligent control systems, especially for a wearable tremor suppression device (WTSD) that can suppress tremor without impeding the user's voluntary motion. Several devices have been developed to reduce tremor; however, the evaluations of these devices have only been done in a controlled lab setting, while the functionality and ability to avoid user injury under the effect of disturbances during daily use have not been investigated. In this study, the performance of a WTSD was tested with several commonly used tremor suppression control systems, i.e., Weight-frequency Fourier Linear Combiner (WFLC), Bandlimited Multiple Fourier Linear Combiner, and enhanced High-order WFLC-based Kalman Filter, on a bench-top tremor simulator. These systems were also tested under the influence of three simulated disturbances that are commonly seen in real life, i.e., data mutation, sensor drift, and measurement loss. The experimental evaluation showed that none of these systems are safe under the disturbances. The tremor power suppression ratio (67.8%-94.2%) of the WTSD was not significantly lowered by the disturbances; however, the error when tracking voluntary motion significantly increased by 8.8 ° -93.6 ° , which may present a safety hazard to the users. The results of this study emphasize the importance of integrating safety measures into intelligent WTSDs.