Electro-thermal-mechanical multiphysics coupling analysis for the short-circuit failure of Si/SiC cascode device

Authors:

Abstract
In this paper, the short-circuit failure mechanisms of 650V Si/SiC Cascode device at 400V DC voltage has been investigated using experiment and finite element method (FEM), considering electrical, thermal and mechanical stresses. It is found that the typical thermal-runaway fault occurs due to the rapid rise of temperature caused by the power loss of high-voltage (HV) JFET in the short-circuit case. The thermal and mechanical co-simulation results show that cracks occur in SiC JFET gate electrode and drain electrode due to mechanical stress, which is reflected in Si/SiC Cascode device leakage current and failure of drain source.

This publication has 13 references indexed in Scilit: