A new wide-angle arthroscopic system: a comparative study with a conventional 30° arthroscopic system
- 8 January 2016
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (5) , 1722-1729
Abstract
Purpose To compare users’ hand movements in performing validated shoulder arthroscopic tasks between a 30° and a wide-angle arthroscopic system, using phantom models with an optical motion analysis system. Methods Twelve orthopaedic residents were enrolled and randomly allocated into two groups. In order to compensate for any learning effect, a Latin square counterbalancing technique was used. An optical motion analysis system was used with markers affixed to pre-designed sites; each participant conducted four validated shoulder arthroscopic tasks using both arthroscopic systems. Each participant was instructed to perform the experiment three times with each arthroscope. The time taken, total path length, number of movements, and average acceleration were analysed. Results Significant differences were observed for the time taken, number of movements, and average acceleration between the two arthroscopic systems (P < 0.05 for all). However, the time taken was not significant. The mean total path length measured 53 ± 38 cm with the 30° arthroscope, while the mean with the wide-angle arthroscope was significantly shorter, at 36 ± 22 cm. The mean number of movements with the 30° and wide-angle arthroscopes were 1974 ± 1305 and 1233 ± 990, respectively, while the average accelerations were 2.6 ± 1.3 and 1.2 ± 0.6 cm/s2, respectively. The mean time taken was 13 % faster when using the wide-angle arthroscopic system, although this was not statistically significant. Conclusion The wide-angle arthroscopic system improved the arthroscope manoeuvre in terms of the total path length, number of movements, and average acceleration required for experimental arthroscopy. This system may help surgeons triangulate the arthroscope and surgical instruments during surgery by expanding the field of view.Keywords
Funding Information
- the Health and Medical R&D Program of the Ministry of Health and Welfare of Korea (HI13C1634)
This publication has 19 references indexed in Scilit:
- Impact of Wide-Angle, High-Definition Endoscopy in the Diagnosis of Colorectal Neoplasia: A Randomized Controlled TrialGastroenterology, 2008
- Individual Skill Progression on a Virtual Reality Simulator for Shoulder ArthroscopyThe American Journal of Sports Medicine, 2008
- Motion Analysis: A Validated Method for Showing Skill Levels in ArthroscopyArthroscopy, 2008
- Cecal Insertion and Withdrawal Times With Wide-Angle Versus Standard Colonoscopes: A Randomized Controlled TrialClinical Gastroenterology and Hepatology, 2008
- Comparison of a supplemental wide field of view versus a single field of view with zoom on performance in minimally invasive surgerySurgical Endoscopy, 2007
- Methodological Infrastructure in Surgical Ergonomics: A Review of Tasks, Models, and Measurement SystemsSurgical Innovation, 2007
- Motion analysisSurgical Endoscopy, 2001
- The Use of Electromagnetic Motion Tracking Analysis To Objectively Measure Open Surgical Skill in The Laboratory-Based ModelJournal of the American College of Surgeons, 2001
- Objective structured assessment of technical skill (OSATS) for surgical residentsBritish Journal of Surgery, 1997
- Objective structured assessment of technical skill (OSATS) for surgical residentsBritish Journal of Surgery, 1997