Cardiac imaging at 7 tesla: Single‐ and two‐spoke radiofrequency pulse design with 16‐channel parallel excitation
Open Access
- 10 September 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (5) , 1210-1219
Abstract
Purpose: Higher signal to noise ratio (SNR) and improved contrast have been demonstrated at ultra‐high magnetic fields (≥7 Tesla [T]) in multiple targets, often with multi‐channel transmit methods to address the deleterious impact on tissue contrast due to spatial variations in B1+ profiles. When imaging the heart at 7T, however, respiratory and cardiac motion, as well as B0 inhomogeneity, greatly increase the methodological challenge. In this study we compare two‐spoke parallel transmit (pTX) RF pulses with static B1+ shimming in cardiac imaging at 7T.Methods: Using a 16‐channel pTX system, slice‐selective two‐spoke pTX pulses and static B1+ shimming were applied in cardiac CINE imaging. B1+ and B0 mapping required modified cardiac triggered sequences. Excitation homogeneity and RF energy were compared in different imaging orientations.Results: Two‐spoke pulses provide higher excitation homogeneity than B1+ shimming, especially in the more challenging posterior region of the heart. The peak value of channel‐wise RF energy was reduced, allowing for a higher flip angle, hence increased tissue contrast. Image quality with two‐spoke excitation proved to be stable throughout the entire cardiac cycle.Conclusion: Two‐spoke pTX excitation has been successfully demonstrated in the human heart at 7T, with improved image quality and reduced RF pulse energy when compared with B1+ shimming. Magn Reson Med 70:1210–1219, 2013.Keywords
Funding Information
- NIH (P41 EB015894, R21 EB009138, R01 EB006835, R01 EB007327, S10 RR26783)
- Deutsche Forschungsgemeinschaft (DFG SCHM 2677-1/1)
- The WM KECK Foundation
This publication has 35 references indexed in Scilit:
- Inversion recovery at 7 T in the human myocardium: Measurement of T1, inversion efficiency and B1+Magnetic Resonance in Medicine, 2012
- Exploring the limits of RF shimming for high‐field MRI of the human headMagnetic Resonance in Medicine, 2006
- Spatial domain method for the design of RF pulses in multicoil parallel excitationMagnetic Resonance in Medicine, 2006
- Fast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneityMagnetic Resonance in Medicine, 2006
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Efficient high‐frequency body coil for high‐field MRIMagnetic Resonance in Medicine, 2004
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- High frequency volume coils for clinical NMR imaging and spectroscopyMagnetic Resonance in Medicine, 1994