Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheep
- 25 August 2010
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (7) , 652-661
Abstract
Background and Objectives The aim of this study was to examine the influence of implant bed preparation, using either Er:YAG laser ablation, piezoelectric surgery or drill osteotomy, on osseointegration of titanium dental implants after 4, 6, and 8 weeks. Material and Methods A total of 108 implants (Camlog) were placed in the pelvis of 6 sheep (18 implants/sheep). Implant sites were prepared by an Er:YAG laser, a dental drill or a piezoelectric device. For each time period, six implants were used for biomechanical removal torque testing and six implants for a semi‐quantitative histological assessment of the bone‐to‐implant contact (BIC). Results An initially missing implant adjusted site preparation led to slightly higher BIC and torque values in the piezoelectric and laser groups due to a press‐fit effect after 4 weeks. Statistical analysis of the average mean BIC after 4, 6, and 8 weeks revealed no significant differences (P > 0.05) between the different osteotomy techniques. Comparison of individual removal torque values showed the highest value for laser osteotomy after 8 weeks (1,698.50 ± 67.52 Nmm), which was significantly higher than the corresponding value for drill osteotomy (P = 0.006). Conclusion Although BIC and removal torque values decreased in the laser and piezoelectric groups at 6 weeks during an active remodeling process, favorable and superior BIC as well as torque values could be demonstrated at 8 weeks. Thus laser and piezoelectric osteotomy seem to be at least comparable to drill osteotomy, concerning early osseointegration and implant stability. Lasers Surg. Med. 42:652–661, 2010.Keywords
This publication has 26 references indexed in Scilit:
- Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Cylindrical versus Conical DrillsClinical Implant Dentistry and Related Research, 2009
- Biomechanical and histomorphometric analyses of the osseointegration of microscrews with different surgical techniques in beagle dogsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2008
- Critical Evaluation of Piezoelectric Osteotomy in Orthognathic Surgery: Operative Technique, Blood Loss, Time Requirement, Nerve and Vessel IntegrityJournal of Oral and Maxillofacial Surgery, 2008
- The Cutting-Edge Technique for Safe Osteotomies in Craniofacial Surgery: The Piezosurgery Bone ScalpelPlastic and Reconstructive Surgery, 2007
- Surface treatments of titanium dental implants for rapid osseointegrationDental Materials, 2007
- Implant Surface Roughness and Bone Healing: a Systematic ReviewJournal of Dental Research, 2006
- Heat generation during implant drilling: The significance of motor speedJournal of Oral and Maxillofacial Surgery, 2002
- Hard tissue ablation with a free running Er:YAG and a Q-switched CO2 laser: a comparative studyApplied Physics B, 2001
- Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbitThe Journal of Prosthetic Dentistry, 1983
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981