Stefan Stübinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan Stübinger has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Brigitte von Rechenberg
7 shared publicationsKarina Klein
Hightech Research Center of Cranio-Maxillofacial Surgery, University of Basel, CH-4031, Basel, Switzerland
4 shared publicationsRobert Sader
4 shared publications- Stephen J. Ferguson
Future Health Technologies, Singapore-ETH Centre, Campus for Research Excellence and Technological Enterprise (CREATE) , Singapore 138602
4 shared publications Michéle Sidler
Musculoskeletal Research Unit Equine Hospital Vetsuisse Faculty ZH University of Zurich Zurich Switzerland
3 shared publicationsAnika Drechsler
Hightech Research Center of Cranio-Maxillofacial Surgery, University of Basel, CH-4031, Basel, Switzerland
2 shared publications
Latest Publications
- Open Access
- 1 January 2016
- Published by Scitechnol Biosoft Pvt. Ltd. in Periodontics and Prosthodontics
- Vol. 2 (1)
Ligature-Induced Peri-Implantitis in Minipigs Revisited
Aim: The ligature-induced defect model still remains the model of first choice to experimentally investigate the cause, effect and treatment approaches of periimplantitis. It was the aim of the present in-vivo trail to revisit the ligature-induced peri-implantitis minipig model regarding its current scientific value and ethical justification in implant research. Materials and methods: Six minipigs were used for the analysis of peri-implant hard and soft tissue structures. Animals were randomly allocated to an experimental silk ligature-induced peri-implantitis group (n=4 animals) and a reference healthy group (n=2 animals). After six weeks mean pocket depths (PD) and bleeding on probing (BOP) measurements were performed just before animals were sacrificed. Results: Overall, ligature-induced peri-implantitis provoked a local inflammation around the experimental implants. Additionally, a loss of crestal bone surrounding the implants could be detected. Mean pocket depths (PD) were 2.2 ± 1.1 mm for healthy animals and 5.4 ± 1.9 mm for peri-implantitis sites. Healthy sites showed a BOP of 60%, whereas peri-implantitis sites disclosed a BOP of 90% within 10 s after probing. Conclusion: Clinical, radiological and histological findings of the present animal experiment supported the overall applicability of the ligature-induced periimplantitis minipig model. A rapid breakdown of peri-implant hard tissues could be detected mainly on the buccal side.
- 1 January 2016
- Published by Scitechnol Biosoft Pvt. Ltd. in Periodontics and Prosthodontics
- Vol. 2 (1)
Open AccessLigature-Induced Peri-Implantitis in Minipigs Revisited
Aim: The ligature-induced defect model still remains the model of first choice to experimentally investigate the cause, effect and treatment approaches of periimplantitis. It was the aim of the present in-vivo trail to revisit the ligature-induced peri-implantitis minipig model regarding its current scientific value and ethical justification in implant research. Materials and methods: Six minipigs were used for the analysis of peri-implant hard and soft tissue structures. Animals were randomly allocated to an experimental silk ligature-induced peri-implantitis group (n=4 animals) and a reference healthy group (n=2 animals). After six weeks mean pocket depths (PD) and bleeding on probing (BOP) measurements were performed just before animals were sacrificed. Results: Overall, ligature-induced peri-implantitis provoked a local inflammation around the experimental implants. Additionally, a loss of crestal bone surrounding the implants could be detected. Mean pocket depths (PD) were 2.2 ± 1.1 mm for healthy animals and 5.4 ± 1.9 mm for peri-implantitis sites. Healthy sites showed a BOP of 60%, whereas peri-implantitis sites disclosed a BOP of 90% within 10 s after probing. Conclusion: Clinical, radiological and histological findings of the present animal experiment supported the overall applicability of the ligature-induced periimplantitis minipig model. A rapid breakdown of peri-implant hard tissues could be detected mainly on the buccal side.
- 11 June 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (6) , 1182-1191
Titanium and hydroxyapatite coating of polyetheretherketone and carbon fiber‐reinforced polyetheretherketone: A pilot study in sheep
Purpose: The purpose of this study was to evaluate the bone formation capability of polyetheretherketone (PEEK) and carbon fiber‐reinforced PEEK (CFR‐PEEK) implants coated with different titanium and hydroxyapatite plasma‐sprayed layers after 2 and 12 weeks. Methods: In six sheep 108 implants were placed in the pelvis. Altogether six different surface modifications were tested. After 2 and 12 weeks, n = 3 implants per group were examined histologically and n = 6 implants per group were tested by a pull‐out test. Results: Biomechanically (p = 0.001) as well as histologically (p > 0.05) surface coating of PEEK/CFR‐PEEK led to an increase of osseointegration from 2 to 12 weeks. After 12 weeks, coated implants demonstrated significant (p < 0.001) higher pull‐out values in comparison to uncoated implants. Overall, the double coating (titanium bond layer and hydroxyapatite top layer) showed the most favorable results after 2 and 12 weeks. Conclusions: Plasma‐sprayed titanium and hydroxyapatite coatings on PEEK or CFR‐PEEK demonstrated a significant improvement of osseointegration. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1182–1191, 2016.
- 11 June 2015
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 104 (6) , 1182-1191
Titanium and hydroxyapatite coating of polyetheretherketone and carbon fiber‐reinforced polyetheretherketone: A pilot study in sheep
Purpose: The purpose of this study was to evaluate the bone formation capability of polyetheretherketone (PEEK) and carbon fiber‐reinforced PEEK (CFR‐PEEK) implants coated with different titanium and hydroxyapatite plasma‐sprayed layers after 2 and 12 weeks. Methods: In six sheep 108 implants were placed in the pelvis. Altogether six different surface modifications were tested. After 2 and 12 weeks, n = 3 implants per group were examined histologically and n = 6 implants per group were tested by a pull‐out test. Results: Biomechanically (p = 0.001) as well as histologically (p > 0.05) surface coating of PEEK/CFR‐PEEK led to an increase of osseointegration from 2 to 12 weeks. After 12 weeks, coated implants demonstrated significant (p < 0.001) higher pull‐out values in comparison to uncoated implants. Overall, the double coating (titanium bond layer and hydroxyapatite top layer) showed the most favorable results after 2 and 12 weeks. Conclusions: Plasma‐sprayed titanium and hydroxyapatite coatings on PEEK or CFR‐PEEK demonstrated a significant improvement of osseointegration. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1182–1191, 2016.
- Open Access
- 11 September 2014
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 5 (3) , 135-157
A Novel Multi-Phosphonate Surface Treatment of Titanium Dental Implants: A Study in Sheep
The aim of the present study was to evaluate a new multi-phosphonate surface treatment (SurfLink®) in an unloaded sheep model. Treated implants were compared to control implants in terms of bone to implant contact (BIC), bone formation, and biomechanical stability. The study used two types of implants (rough or machined surface finish) each with either the multi-phosphonate Wet or Dry treatment or no treatment (control) for a total of six groups. Animals were sacrificed after 2, 8, and 52 weeks. No adverse events were observed at any time point. At two weeks, removal torque showed significantly higher values for the multi-phosphonate treated rough surface (+32% and +29%, Dry and Wet, respectively) compared to rough control. At 52 weeks, a significantly higher removal torque was observed for the multi-phosphonate treated machined surfaces (+37% and 23%, Dry and Wet, respectively). The multi-phosphonate treated groups showed a positive tendency for higher BIC with time and increased new-old bone ratio at eight weeks. SEM images revealed greater amounts of organic materials on the multi-phosphonate treated compared to control implants, with the bone fracture (from the torque test) appearing within the bone rather than at the bone to implant interface as it occurred for control implants.
- 11 September 2014
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 5 (3) , 135-157
Open AccessA Novel Multi-Phosphonate Surface Treatment of Titanium Dental Implants: A Study in Sheep
The aim of the present study was to evaluate a new multi-phosphonate surface treatment (SurfLink®) in an unloaded sheep model. Treated implants were compared to control implants in terms of bone to implant contact (BIC), bone formation, and biomechanical stability. The study used two types of implants (rough or machined surface finish) each with either the multi-phosphonate Wet or Dry treatment or no treatment (control) for a total of six groups. Animals were sacrificed after 2, 8, and 52 weeks. No adverse events were observed at any time point. At two weeks, removal torque showed significantly higher values for the multi-phosphonate treated rough surface (+32% and +29%, Dry and Wet, respectively) compared to rough control. At 52 weeks, a significantly higher removal torque was observed for the multi-phosphonate treated machined surfaces (+37% and 23%, Dry and Wet, respectively). The multi-phosphonate treated groups showed a positive tendency for higher BIC with time and increased new-old bone ratio at eight weeks. SEM images revealed greater amounts of organic materials on the multi-phosphonate treated compared to control implants, with the bone fracture (from the torque test) appearing within the bone rather than at the bone to implant interface as it occurred for control implants.
- 2 July 2014
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (5) , 572-580
Evaluation of local cancellous bone amelioration by poly‐l‐dl‐lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep
Objectives: The aim of this study was to evaluate the clinical performance of local cancellous bone amelioration by a 70:30 poly‐(l‐lactide‐co‐d,l‐Lacide) copolymer with two different implant designs on primary stability and after 4 and 12 weeks of healing time.Material and methods: In six sheep, n = 36 implants (TH) with a conditioned, sandblasted, thermal acid‐etched micro‐rough surface and n = 36 implants (NB) with a highly crystalline and phosphate‐enriched anodized titanium oxide surface were placed in the pelvic bone. Using an ultrasound‐based process named Constant Amelioration Process (CAP), half of peri‐implant trabecular bone structures were locally tested with 70:30 poly‐(l‐lactide‐co‐d,l‐Lacide) copolymer in both implant groups, TH and NB. The CAP technology employs ultrasonic energy to liquefy 70:30 poly‐(l‐lactide‐co‐d,l‐Lacide) which enters the inter‐trabecular space, leading to local reinforcement of the cancellous bone structure after solidification of the copolymer. The CAP test group was compared with reference implants placed with the conventional site preparation according to the manufacturers' description. Primary stability was assessed by the measurement of torque‐in values and implant stability quotient (ISQ; n = 18 per group). Secondary stability was analyzed by biomechanical removal torque testing after 4 and 12 weeks (n = 9 per group).Results: Insertion torque value (23.3 N cm ± 13.6) of reference TH implants demonstrated a statistically significant (P = 0.00) difference in comparison with test TH implants (41.9 N cm ± 19.5). Reference NB implants revealed a statistically significant (P = 0.03) lower insertion torque value (23.7 N cm ± 13.5) than test NB implants (39.7 N cm ± 18.6). ISQ values increased for all implants from initial implant placement until sacrifice at 12 weeks. Reference TH implants tended to result in an increase in torque values from 4 weeks (181.9 N cm ± 22.8) to 12 weeks (225.7 N cm ± 47.4). This trend could be also proven for implants of test sites (4 week: 176.8 N cm ± 24.1; 12 week: 201.5 N cm ± 53.4). For reference, NB implants a non‐significant increase in removal torque values from 4 weeks (146. 7 N cm ± 18.0) to 12 weeks (170.2 N cm ± 40.4) was observed. Removal torque values of test NB implants did not increase from 4 weeks (153.3 N cm ± 21.5) to 12 weeks (146.1 N cm ± 37.5).Conclusion: Biomechanical data proved significantly enhanced primary stability of dental implants after local amelioration without long‐term sequelae and irrespective of implant design. After 4‐ and 12‐week healing time, removal torque of locally test implants was as high as for control implants, and osseointegration was therefore not influenced by the CAP process. No correlation between ISQ values and torque values was found.
- 2 July 2014
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (5) , 572-580
Evaluation of local cancellous bone amelioration by poly‐l‐dl‐lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep
Objectives: The aim of this study was to evaluate the clinical performance of local cancellous bone amelioration by a 70:30 poly‐(l‐lactide‐co‐d,l‐Lacide) copolymer with two different implant designs on primary stability and after 4 and 12 weeks of healing time.Material and methods: In six sheep, n = 36 implants (TH) with a conditioned, sandblasted, thermal acid‐etched micro‐rough surface and n = 36 implants (NB) with a highly crystalline and phosphate‐enriched anodized titanium oxide surface were placed in the pelvic bone. Using an ultrasound‐based process named Constant Amelioration Process (CAP), half of peri‐implant trabecular bone structures were locally tested with 70:30 poly‐(l‐lactide‐co‐d,l‐Lacide) copolymer in both implant groups, TH and NB. The CAP technology employs ultrasonic energy to liquefy 70:30 poly‐(l‐lactide‐co‐d,l‐Lacide) which enters the inter‐trabecular space, leading to local reinforcement of the cancellous bone structure after solidification of the copolymer. The CAP test group was compared with reference implants placed with the conventional site preparation according to the manufacturers' description. Primary stability was assessed by the measurement of torque‐in values and implant stability quotient (ISQ; n = 18 per group). Secondary stability was analyzed by biomechanical removal torque testing after 4 and 12 weeks (n = 9 per group).Results: Insertion torque value (23.3 N cm ± 13.6) of reference TH implants demonstrated a statistically significant (P = 0.00) difference in comparison with test TH implants (41.9 N cm ± 19.5). Reference NB implants revealed a statistically significant (P = 0.03) lower insertion torque value (23.7 N cm ± 13.5) than test NB implants (39.7 N cm ± 18.6). ISQ values increased for all implants from initial implant placement until sacrifice at 12 weeks. Reference TH implants tended to result in an increase in torque values from 4 weeks (181.9 N cm ± 22.8) to 12 weeks (225.7 N cm ± 47.4). This trend could be also proven for implants of test sites (4 week: 176.8 N cm ± 24.1; 12 week: 201.5 N cm ± 53.4). For reference, NB implants a non‐significant increase in removal torque values from 4 weeks (146. 7 N cm ± 18.0) to 12 weeks (170.2 N cm ± 40.4) was observed. Removal torque values of test NB implants did not increase from 4 weeks (153.3 N cm ± 21.5) to 12 weeks (146.1 N cm ± 37.5).Conclusion: Biomechanical data proved significantly enhanced primary stability of dental implants after local amelioration without long‐term sequelae and irrespective of implant design. After 4‐ and 12‐week healing time, removal torque of locally test implants was as high as for control implants, and osseointegration was therefore not influenced by the CAP process. No correlation between ISQ values and torque values was found.
- 21 May 2014
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (8) , 898-908
Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model
Objectives: The aim of this study was to compare two different surfaces of one uniform macro‐implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen.Material and methods: In six mature sheep, n = 36 implants with a highly crystalline and phosphate‐enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid‐etched surface (SLA) were placed in the pelvic bone. TiU implants were custom‐made to match the SLA implant design. The implant stability and bone‐to‐implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B‐SEM), light microscopy (LM), micro‐CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed.Results: Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B‐SEM. BIC values (B‐SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2‐ to 4‐week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B‐SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P ≤ 0.05) than after 2 weeks (B‐SEM; LM). Biomechanical data confirmed the histological data.Conclusion: The two surfaces proved comparable osseointegration in this sheep model.
- 21 May 2014
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (8) , 898-908
Comparison of two dental implant surface modifications on implants with same macrodesign: an experimental study in the pelvic sheep model
Objectives: The aim of this study was to compare two different surfaces of one uniform macro‐implant design in order to focus exclusively on the osseointegration properties after 2, 4 and 8 weeks and to discuss the animal model chosen.Material and methods: In six mature sheep, n = 36 implants with a highly crystalline and phosphate‐enriched anodized titanium oxide surface (TiU) and n = 36 implants with a hydrophilic, sandblasted, large grit and acid‐etched surface (SLA) were placed in the pelvic bone. TiU implants were custom‐made to match the SLA implant design. The implant stability and bone‐to‐implant contact (BIC) were assessed by resonance frequency (ISQ), backscatter scanning electron microscopy (B‐SEM), light microscopy (LM), micro‐CT and intravital fluorochrome staining. Biomechanical removal torque testing was performed.Results: Overall, no statistically significant differences in BIC total (trabecular + cortical) between TiU and SLA were found via LM and B‐SEM. BIC values (B‐SEM; LM) in both groups revealed a steady rise in trabecular bone attachment to the implant surface after 2, 4 and 8 weeks. In the 2‐ to 4‐week time interval in the TiU group (P = 0.005) as well as in the SLA group (P = 0.01), a statistically significant increase in BIC trabecular could be observed via LM. B‐SEM values confirmed the statistically significant increase for TiU (P = 0.001). In both groups, BIC trabecular values after 8 weeks were significantly higher (P ≤ 0.05) than after 2 weeks (B‐SEM; LM). Biomechanical data confirmed the histological data.Conclusion: The two surfaces proved comparable osseointegration in this sheep model.
- 6 April 2013
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101 (7) , 1154-1163
Histological and biomechanical analysis of porous additive manufactured implants made by direct metal laser sintering: A pilot study in sheep
Objectives: It was the aim of this study to analyze osseointegrative properties of porous additive manufactured titanium implants made by direct metal laser sintering in a sheep model after an implantation period of 2 and 8 weeks. Material and Methods: Three different types of implants were placed in the pelvis of six sheep. In each sheep were placed three standard machined (M), three sandblasted and etched (SE), and three porous additive manufactured (AM) implants. Of these three implants (one per type) were examined histologically and six implants were tested biomechanically. Additionally a semiquantitative histomorphometrical and qualitative fluorescent microscopic analysis were performed. Results: After 2 and 8 weeks bone-to-implant-contact (BIC) values of the AM surface (2w: 20.49% ± 5.18%; 8w: 43.91% ± 9.69%) revealed no statistical significant differences in comparison to the M (2w: 20.33% ± 11.50%; 8w: 25.33% ± 4.61%) and SE (2w: 43.67 ± 12.22%; 8w: 53.33 ± 8.96%) surfaces. AM surface showed the highest increase of the BIC between the two observation time points. Considering the same implantation period histomorphometry and fluorescent labelling disclosed no significant differences in the bone surrounding the three implants groups. In contrast Removal-torque-test showed a significant improve in fixation strength (P ≤ 0.001) for the AM (1891.82 ± 308, 44 Nmm) surface after eight weeks in comparison to the M (198.93±88,04 Nmm) and SE (730.08 ± 151,89 Nmm) surfaces. Conclusion: All three surfaces (M, SE, and AM) showed sound osseointegration. AM implants may offer a possible treatment option in clinics for patients with compromised bone situations. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 1154–1163, 2013.
- 6 April 2013
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101 (7) , 1154-1163
Histological and biomechanical analysis of porous additive manufactured implants made by direct metal laser sintering: A pilot study in sheep
Objectives: It was the aim of this study to analyze osseointegrative properties of porous additive manufactured titanium implants made by direct metal laser sintering in a sheep model after an implantation period of 2 and 8 weeks. Material and Methods: Three different types of implants were placed in the pelvis of six sheep. In each sheep were placed three standard machined (M), three sandblasted and etched (SE), and three porous additive manufactured (AM) implants. Of these three implants (one per type) were examined histologically and six implants were tested biomechanically. Additionally a semiquantitative histomorphometrical and qualitative fluorescent microscopic analysis were performed. Results: After 2 and 8 weeks bone-to-implant-contact (BIC) values of the AM surface (2w: 20.49% ± 5.18%; 8w: 43.91% ± 9.69%) revealed no statistical significant differences in comparison to the M (2w: 20.33% ± 11.50%; 8w: 25.33% ± 4.61%) and SE (2w: 43.67 ± 12.22%; 8w: 53.33 ± 8.96%) surfaces. AM surface showed the highest increase of the BIC between the two observation time points. Considering the same implantation period histomorphometry and fluorescent labelling disclosed no significant differences in the bone surrounding the three implants groups. In contrast Removal-torque-test showed a significant improve in fixation strength (P ≤ 0.001) for the AM (1891.82 ± 308, 44 Nmm) surface after eight weeks in comparison to the M (198.93±88,04 Nmm) and SE (730.08 ± 151,89 Nmm) surfaces. Conclusion: All three surfaces (M, SE, and AM) showed sound osseointegration. AM implants may offer a possible treatment option in clinics for patients with compromised bone situations. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 1154–1163, 2013.
- 21 November 2012
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 16 (4) , 540-551
Deviations between Placed and Planned Implant Positions: An Accuracy Pilot Study of Skeletally Supported Stereolithographic Surgical Templates
Purpose: The aim of the present study was to evaluate deviations between virtually planned and placed implants by the use of skeletally supported stereolithographic templates.Materials and Methods: Ten consecutive patients were selected for virtual three‐dimensional implant planning using the FacilitateTM software (Astra Tech AB, Mölndal, Sweden). Computer tomography images were obtained in the pre‐ and postoperative phase. Four deviation parameters (i.e. global, angular, depth, and lateral deviation) were defined and calculated between the planned and the placed implants, using the coordinates of their respective apical and coronal points.Results: Deviations at the coronal positions appeared to be smaller (95% confidence interval: 0.15–1.0) as compared with apical positions (95% confidence interval: 0.14–1.1). But only the difference with regard to lateral measurements appeared to be statistically significant (p = .03). Except for depth (p = .01), no significant association between mesial or more distal locations could be detected concerning global (p = .07), lateral (p = .87), and angular (p = .56) values in mixed model analyses. Overall, there was a slight tendency for higher values for more distal locations.Conclusion: As slight deviations between planned and placed implants especially may occur even with skeletal‐supported templates, the clinician should be aware not to overestimate advocated surgical safety by using static navigation tools.
- 21 November 2012
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 16 (4) , 540-551
Deviations between Placed and Planned Implant Positions: An Accuracy Pilot Study of Skeletally Supported Stereolithographic Surgical Templates
Purpose: The aim of the present study was to evaluate deviations between virtually planned and placed implants by the use of skeletally supported stereolithographic templates.Materials and Methods: Ten consecutive patients were selected for virtual three‐dimensional implant planning using the FacilitateTM software (Astra Tech AB, Mölndal, Sweden). Computer tomography images were obtained in the pre‐ and postoperative phase. Four deviation parameters (i.e. global, angular, depth, and lateral deviation) were defined and calculated between the planned and the placed implants, using the coordinates of their respective apical and coronal points.Results: Deviations at the coronal positions appeared to be smaller (95% confidence interval: 0.15–1.0) as compared with apical positions (95% confidence interval: 0.14–1.1). But only the difference with regard to lateral measurements appeared to be statistically significant (p = .03). Except for depth (p = .01), no significant association between mesial or more distal locations could be detected concerning global (p = .07), lateral (p = .87), and angular (p = .56) values in mixed model analyses. Overall, there was a slight tendency for higher values for more distal locations.Conclusion: As slight deviations between planned and placed implants especially may occur even with skeletal‐supported templates, the clinician should be aware not to overestimate advocated surgical safety by using static navigation tools.
- Open Access
- 8 March 2012
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 32
Osseointegration and biocompatibility of different metal implants - a comparative experimental investigation in sheep
Background: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.Methods: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.Results: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.Conclusion: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.
- 8 March 2012
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 32
Open AccessOsseointegration and biocompatibility of different metal implants - a comparative experimental investigation in sheep
Background: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.Methods: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.Results: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.Conclusion: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.
- 29 September 2010
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (8) , 743-751
Comparison of Er:YAG laser and piezoelectric osteotomy: An animal study in sheep
Objectives: It was the aim of this study to compare the feasibility of complete osteotomy of long bones in sheep using a newly designed variable square pulsed Er:YAG laser and piezoelectric surgery. In addition to uneventful bone healing after laser osteotomy, the goal was to assess the possibility to cut thick bony structures with both techniques in a surgically acceptable time frame of 2–3 minutes.Material and Methods: A tibia midshaft osteotomy was performed in 24 sheep using either an Er:YAG laser (n = 12) or piezoelectric device (n = 12). Laser and piezoelectric groups were divided in two subgroups (n = 6) with sheep sacrificed after 2 and 3 months, respectively. A complete radiological, histological and histomorphometric analysis was performed to compare the course of bone/fracture healing and remodelling.Results: Laser and piezoelectric osteotomies of the sheep tibia up to a depth of 22 mm were possible without any thermal damage. Radiological and histological results after 2 months showed primary gap healing with distinct periosteal callus formation on the transcortex. After 3 months, radiological and histological analysis revealed less callus formation on the transcortex, with almost no visible osteotomy gap and a distinct formation of lamellar bone crossing the original osteotomy gap.Conclusion: Er:YAG laser osteotomy can successfully be used in long bones with a depth of up to 22 mm, thus challenging the dogma of adverse effects of laser osteotomy due to thermal or other damages. Lasers Surg. Med. 42:743–751, 2010
- 29 September 2010
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (8) , 743-751
Comparison of Er:YAG laser and piezoelectric osteotomy: An animal study in sheep
Objectives: It was the aim of this study to compare the feasibility of complete osteotomy of long bones in sheep using a newly designed variable square pulsed Er:YAG laser and piezoelectric surgery. In addition to uneventful bone healing after laser osteotomy, the goal was to assess the possibility to cut thick bony structures with both techniques in a surgically acceptable time frame of 2–3 minutes.Material and Methods: A tibia midshaft osteotomy was performed in 24 sheep using either an Er:YAG laser (n = 12) or piezoelectric device (n = 12). Laser and piezoelectric groups were divided in two subgroups (n = 6) with sheep sacrificed after 2 and 3 months, respectively. A complete radiological, histological and histomorphometric analysis was performed to compare the course of bone/fracture healing and remodelling.Results: Laser and piezoelectric osteotomies of the sheep tibia up to a depth of 22 mm were possible without any thermal damage. Radiological and histological results after 2 months showed primary gap healing with distinct periosteal callus formation on the transcortex. After 3 months, radiological and histological analysis revealed less callus formation on the transcortex, with almost no visible osteotomy gap and a distinct formation of lamellar bone crossing the original osteotomy gap.Conclusion: Er:YAG laser osteotomy can successfully be used in long bones with a depth of up to 22 mm, thus challenging the dogma of adverse effects of laser osteotomy due to thermal or other damages. Lasers Surg. Med. 42:743–751, 2010
- 25 August 2010
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (7) , 652-661
Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheep
Background and Objectives The aim of this study was to examine the influence of implant bed preparation, using either Er:YAG laser ablation, piezoelectric surgery or drill osteotomy, on osseointegration of titanium dental implants after 4, 6, and 8 weeks. Material and Methods A total of 108 implants (Camlog) were placed in the pelvis of 6 sheep (18 implants/sheep). Implant sites were prepared by an Er:YAG laser, a dental drill or a piezoelectric device. For each time period, six implants were used for biomechanical removal torque testing and six implants for a semi‐quantitative histological assessment of the bone‐to‐implant contact (BIC). Results An initially missing implant adjusted site preparation led to slightly higher BIC and torque values in the piezoelectric and laser groups due to a press‐fit effect after 4 weeks. Statistical analysis of the average mean BIC after 4, 6, and 8 weeks revealed no significant differences (P > 0.05) between the different osteotomy techniques. Comparison of individual removal torque values showed the highest value for laser osteotomy after 8 weeks (1,698.50 ± 67.52 Nmm), which was significantly higher than the corresponding value for drill osteotomy (P = 0.006). Conclusion Although BIC and removal torque values decreased in the laser and piezoelectric groups at 6 weeks during an active remodeling process, favorable and superior BIC as well as torque values could be demonstrated at 8 weeks. Thus laser and piezoelectric osteotomy seem to be at least comparable to drill osteotomy, concerning early osseointegration and implant stability. Lasers Surg. Med. 42:652–661, 2010.
- 25 August 2010
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (7) , 652-661
Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheep
Background and Objectives The aim of this study was to examine the influence of implant bed preparation, using either Er:YAG laser ablation, piezoelectric surgery or drill osteotomy, on osseointegration of titanium dental implants after 4, 6, and 8 weeks. Material and Methods A total of 108 implants (Camlog) were placed in the pelvis of 6 sheep (18 implants/sheep). Implant sites were prepared by an Er:YAG laser, a dental drill or a piezoelectric device. For each time period, six implants were used for biomechanical removal torque testing and six implants for a semi‐quantitative histological assessment of the bone‐to‐implant contact (BIC). Results An initially missing implant adjusted site preparation led to slightly higher BIC and torque values in the piezoelectric and laser groups due to a press‐fit effect after 4 weeks. Statistical analysis of the average mean BIC after 4, 6, and 8 weeks revealed no significant differences (P > 0.05) between the different osteotomy techniques. Comparison of individual removal torque values showed the highest value for laser osteotomy after 8 weeks (1,698.50 ± 67.52 Nmm), which was significantly higher than the corresponding value for drill osteotomy (P = 0.006). Conclusion Although BIC and removal torque values decreased in the laser and piezoelectric groups at 6 weeks during an active remodeling process, favorable and superior BIC as well as torque values could be demonstrated at 8 weeks. Thus laser and piezoelectric osteotomy seem to be at least comparable to drill osteotomy, concerning early osseointegration and implant stability. Lasers Surg. Med. 42:652–661, 2010.