Utilizing augmented artificial intelligence for aminoacidopathies using collaborative laboratory integrated reporting- A cross-sectional study
Open Access
- 22 September 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 82, 104651
Abstract
Ntries utilizing Clinical Laboratory Integrated Reports (CLIR). Methods: This was a cross sectional prospective single center study. Twenty-two amino acids were analyzed in each sample received for one year at the clinical laboratory. Data was divided into reference and case data files after interpretation by a team of pathologists and technologists. All PAA samples were analyzed using ion-exchange high-performance chromatography. The CLIR application of Amino Acid in Plasma (AAQP) was used for statistical analysis for both data sets and post-analytical interpretive tools using a single condition tool was applied. Result: The majority of 92% (n = 1913) of PAA profiles out of the total 2081 tests run were non-diagnostic; the PAA values were within the age-specific RI. The PAA median was in close comparison close to the 50th percentile of reference data available in CLIR software. Out of the total 2081 tests run, one hundred and sixty-eight had abnormal PAA levels; 27.38% were labeled as non-fasting samples, and the main aminoacidopathies identified were Phenylketonuria and Maple Syrup Urine Disorder. Conclusion: An agreement of >95% was observed between the reporting done by the pathologists and technologists’ team and then after the application of CLIR. Augmented artificial intelligence using CLIR can improve the accuracy of reporting rare aminoacidopathies in a developing country like ours. HIGHLIGHTS Plasma amino acids helps in diagnosing and monitoring of various aminoacidopathies.Few aminoacidopathies present with a grossly abnormal investigation profile, with few diseases having subtle deviations.Their is 98% concordance of diagnosis concordance of diagnosis of aminoacidopathies between our lab and CLIR.CLIR tools can be utilized in a newborn screening program for screening and diagnosis in future....Keywords
This publication has 27 references indexed in Scilit:
- Precision newborn screening for lysosomal disordersGenetics in Medicine, 2018
- Moonlighting newborn screening markers: the incidental discovery of a second-tier test for Pompe diseaseGenetics in Medicine, 2018
- Aminoacidopathies: Prevalence, Etiology, Screening, and Treatment OptionsBiochemical Genetics, 2017
- Postanalytical tools improve performance of newborn screening by tandem mass spectrometryGenetics in Medicine, 2014
- Systematic Data Collection to Inform Policy Decisions: Integration of the Region 4 Stork (R4S) Collaborative Newborn Screening Database to Improve MS/MS Newborn Screening in Washington State2013
- Inborn errors of metabolism and expanded newborn screening: review and updateCritical Reviews in Clinical Laboratory Sciences, 2013
- Diagnostic challenges of aminoacidopathies and organic acidemias in a developing country: A twelve-year experienceClinical Biochemistry, 2013
- Diagnostic work-up in acute conditions of inborn errors of metabolism and storage diseases2013
- Enhanced interpretation of newborn screening results without analyte cutoff valuesGenetics in Medicine, 2012
- Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry: A worldwide collaborative projectGenetics in Medicine, 2011