Comparing the Biomechanical Stability of Cerclage Cable with Plate Insert Versus Locking Screw in Periprosthetic Humeral Fracture
- 21 February 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (9) , 817-822
Abstract
Background: In the setting of periprosthetic humeral fractures, the humeral stem of the implant represents a substantial challenge to the optimal method of proximal fixation. This study aimed to compare the initial biomechanical stability provided by cerclage cables with a locking plate insert versus bicortical locking screws (i.e., the gold standard for fixation) in fresh cadaveric humeri. Methods: After calculating the sample size, we utilized 10 sets of cadaveric specimens and created a 5-mm osteotomy gap 120 mm distal to the tip of the greater tuberosity, simulating a Wright and Cofield type-B periprosthetic humeral fracture on each specimen. Using 3 locking screws for distal fragment fixation, identical in all specimens, the specimens were assigned to Group A (3 cerclage cables with a plate insert) or Group B (3 locking bicortical screws) for proximal fragment fixation. Biomechanical tests included stiffness in varus and valgus bending, torsion, and axial compression, and a single load to failure. Results: No significant differences were observed in the biomechanical metrics between the 2 groups. Conclusions: Our study revealed that fixation with use of cerclage cables with a plate insert demonstrated biomechanical stability comparable with that of bicortical locking screw fixation when addressing the proximal fragment in Wright and Cofield type-B periprosthetic humeral fractures. Clinical Relevance: For proximal fragment fixation of periprosthetic humeral fractures, cerclage cables with a plate insert can be utilized as an effective fixation method that offers initial fixation strength that is comparable to the use of 3 locking bicortical screws.Keywords
This publication has 23 references indexed in Scilit:
- Locking attachment plate fixation around a well-fixed stem in periprosthetic femoral shaft fracturesArchives of orthopaedic and trauma surgery, 2017
- Periprosthetic fracture fixation in osteoporotic boneInjury, 2016
- Past and present of the use of cerclage wires in orthopedicsEuropean Journal of Orthopaedic Surgery & Traumatology, 2014
- Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fracturesInternational Orthopaedics, 2013
- The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniquesInternational Orthopaedics, 2012
- The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysisArchives of orthopaedic and trauma surgery, 2009
- Complications of total shoulder arthroplasty: Are they fewer or different?Journal of Shoulder and Elbow Surgery, 2006
- Biomechanical testing of the LCP – how can stability in locked internal fixators be controlled?Injury, 2003
- pQCT bone strength index may serve as a better predictor than bone mineral density for long bone breaking strengthJournal of Bone and Mineral Metabolism, 2003
- Periprosthetic humeral fractures: Mechanisms of fracture and treatment optionsJournal of Shoulder and Elbow Surgery, 1998