Usability Evaluation of an Electrically Powered Orthopedic Exerciser: Focus Group Interview and Satisfaction Survey Study
Open Access
- 30 May 2025
- journal article
- orthopedics
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 12 (1) , e60607
Abstract
Background: Musculoskeletal disorders significantly impair physical function and quality of life, necessitating systematic rehabilitation. Electrically powered orthopedic exercisers, such as continuous passive motion devices, are widely used to enhance joint mobility and muscle recovery. However, existing devices often lack advanced functionalities and user-specific adaptability, limiting their effectiveness. To address these shortcomings, the Rebless Pro was developed as a novel device supporting active and passive exercises with personalized treatment programs. Objective: This study aimed to conduct a formative usability evaluation of the Rebless Pro prototype using focus group interviews (FGIs) and satisfaction surveys with health care professionals specializing in rehabilitation medicine. The goal was to identify areas for improvement to enhance the safety, usability, and information clarity of the device. Methods: Usability evaluation was performed at the National Rehabilitation Center with 10 participants (5 physiatrists and 5 physical therapists) who had prior experience using similar devices. FGIs were conducted to collect qualitative insights into user experiences, while satisfaction surveys provided quantitative data on ease of use of the user interface and identifiability and understanding of information. Data collection focused on identifying risk factors and usability challenges. Results: Three key areas for improvement were identified: (1) product upgrades to ensure patient safety, including adjustments to exercise speed and resistance; (2) hardware and software improvements to improve usability, including adjustments to the location of the emergency button and improvements to the graphical user interface elements; and (3) improvements to the user manual, including detailed contraindications, patient criteria, and clearer operating instructions. Although the mean score of physiatrists (mean 4.463, SD 0.298) was higher than that of physical therapists (mean 4.114, SD 0.829) in terms of the ease of use of the user interface, the difference was not statistically significant (P=.69). Similarly, in the category of identifiability and understanding of information, higher scores were again reported by physiatrists (mean score 4.467, SD 0.506) than by physical therapists (mean 3.733, SD 0.894), but this difference was also not statistically significant (P=.22). Conclusions: Usability evaluation provided actionable insights into improving the Rebless Pro’s safety, usability, and information clarity. To further refine the device, iterative usability evaluations involving both health care professionals and patients are recommended. These efforts are expected to contribute to the development of a safe, effective, and user-friendly electrically powered orthopedic exerciser suitable for commercialization.Keywords
This publication has 25 references indexed in Scilit:
- Safety, performance and user satisfaction study of the new ABLE lower-limb exoskeleton for individuals with SCI: the result of a co-creation process with clinicians and patientsResearch Square, 2023
- A Study on Standard for Safety Requirements for Care RobotsJournal of Rehabilitation Welfare Engineering & Assistive Technology, 2022
- A Qualitative Study on the User Experience of Manual/Electric Hybrid Wheelchairs in Leisure Activity Participation: Focusing on Focus Group InterviewJournal of Korean Society of Occupational Therapy, 2021
- Impact of Design on Medical Device SafetyTherapeutic Innovation & Regulatory Science, 2019
- Electromagnetic compatibility tests and informed consent, in the development of research on biomedical equipment design2019
- Using Formal Task Analytic Models to Support User Manual Development: An LVAD Case StudyProceedings of the International Symposium on Human Factors and Ergonomics in Health Care, 2015
- Applying Heuristic Evaluation on Medical Devices User Manuals2015
- Multidisciplinary team care in rehabilitation: An overview of reviewsJournal of Rehabilitation Medicine, 2012
- Conceptualization of an exoskeleton Continuous Passive Motion(CPM) device using a link structure2011
- Clinical application of basic research on continuous passive motion for disorders and injuries of synovial joints: A preliminary report of a feasibility studyJournal of Orthopaedic Research, 1983