Concept of variable angle locking—evolution and mechanical evaluation of a recent technology
Authors:
- 14 April 2015
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (7) , 988-992
Abstract
Applications for fracture‐adapted screw positioning offered by variable angle locking screws are increasing. The locking strength of the variable angle locking mechanism at different insertion angles was compared to conventional fixed angle locking screws. Stainless steel (S) and titanium (Ti) variable and fixed angle 2.4 mm locking screws, inserted at different inclinations (0°−15°), and locked at 0.8 Nm were subjected to a load‐to‐failure test. Ultimate failure moment at the screw‐head interface and failure mode of the screws were determined. Significant differences were detected by one‐way ANOVA ( p < 0.05). Stainless steel and titanium variable angle locking screws inserted at 2°−10° inclination exhibited a failure moment comparable to the 0° position (S 1.67± 0.04 Nm; Ti 1.67 ± 0.14 Nm) and failed predominantly at the screw neck, with the head remaining fixed to the plate. Inserted at 15° inclination, screws revealed a lower failure moment (S 1.33 ± 0.06 Nm, Ti 1.58 ± 0.05Nm), and failed predominantly by breakout of the head thread. Fixed angle locking screws inserted at an inclination >2° did not lock properly in the plate hole, providing insufficient locking strength. Variable angle locking screws offer a stable head‐locking mechanism at different inclinations, comparable to the locking strength of orthogonal inserted fixed angle locking screws. Marginal inclinations >15° should be used with care. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:988–992, 2015.Keywords
Funding Information
- DePuy Synthes
This publication has 15 references indexed in Scilit:
- Mulitdirektional winkelstabile volare Platte bei distaler RadiusfrakturDer Unfallchirurg, 2013
- Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius platesBiomedical Engineering / Biomedizinische Technik, 2013
- Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?Injury, 2012
- Erste Ergebnisse der multidirektional-winkelstabilen palmaren Osteosynthese der distalen RadiusfrakturDer Unfallchirurg, 2010
- Fractures of the Distal Tibia Treated with Polyaxial Locking PlatingClinical Orthopaedics and Related Research, 2009
- Current Concepts in Volar Fixed-angle Fixation of Unstable Distal Radius FracturesClinical Orthopaedics and Related Research, 2006
- Locked Internal FixatorJournal of Orthopaedic Trauma, 2004
- Guidelines for the clinical application of the LCPInjury, 2003
- Strength Recovery in Fractured Sheep Tibia Treated with a Plate or an Internal Fixator: An Experimental Study with a Two-Year Follow-upJournal of Orthopaedic Trauma, 1997
- The biomechanics of the PC-Fix internal fixatorInjury, 1995