Influences of Power Electronic Converters on Voltage–Current Behaviors During Faults in DGUs—Part I: Wind Energy Conversion Systems
Authors:
- S. A. SalehSSS. A. Saleh
- A. S. AljankaweyAAA. S. Aljankawey
- M. S. Abu-KhaizaranMAM. S. Abu-Khaizaran
- B. AlsayidBAB. Alsayid
- 5 January 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 51 (4) , 2819-2831
Abstract
The growing interest in clean and sustainable electric energy pushes toward increasing the interconnection of wind energy conversion systems (WECSs) to utility grids. The designs of the majority of WECSs employ power electronic converters (PECs), which generally have nonlinear and switched characteristics. The characteristics, operation, and control of PECs in WECSs can result in nonconventional voltage-current behaviors during faults. This paper investigates the voltage-current behaviors during faults that occur in grid-connected WECSs. Two types of WECSs are considered in this paper, which are the doubly fed induction generators and permanent magnet generator based WECSs. The voltage-current behaviors are investigated in experimentations for different faults occurring in different parts of the test grid-connected WECSs.Keywords
This publication has 32 references indexed in Scilit:
- Transients in Wind Power Plants—Part II: Case StudiesIEEE Transactions on Industry Applications, 2012
- Resolution-Level-Controlled WM Inverter for PMG-Based Wind Energy Conversion SystemIEEE Transactions on Industry Applications, 2012
- Implementing and testing d − q WPT-based digital protection for micro-grid systems2011
- Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer During Symmetrical and Asymmetrical Grid FaultsIEEE Transactions on Power Electronics, 2011
- Investigation on the Faulty State of DFIG in a MicrogridIEEE Transactions on Power Electronics, 2010
- A Novel Control Strategy for a Variable-Speed Wind Turbine With a Permanent-Magnet Synchronous GeneratorIEEE Transactions on Industry Applications, 2009
- Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid FaultsIEEE Transactions on Power Electronics, 2009
- A Review of the State of the Art of Power Electronics for Wind TurbinesIEEE Transactions on Power Electronics, 2009
- Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage ConditionsIEEE Transactions on Energy Conversion, 2007
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006