Clinical and ultrasonographical follow-up after standard removal of distal radius volar plates positioned distal to the watershed line
- 1 October 2020
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 30 (7) , 1215-1219
Abstract
Marginal fracture types of the distal radius may require volar plate positioning distal to the watershed line. Subsequently, plate prominence with direct friction with the flexor tendons occurs which is associated with flexor tendon pathology. Standard plate removal can be proposed. This cohort study examined clinical outcome, patient satisfaction and ultrasonographical assessment of the relation of the flexor pollicis longus (FPL) and the volar rim after standard plate removal. Twenty patients with volar plate prominence after osteosynthesis for distal radius fractures were included. Plate removal was performed at least 4 months after initial surgery. The mean age was 60 years (range 39-84). The average delay from hardware removal to assessment was 2.9 years (range 1.0-5.0 years). Mean flexion, extension and radial deviation were significantly decreased (p<0.05) compared to the contralateral side, while ulnar deviation, pro- and supination and grip strength were not. Mean QuickDASH score was 21.5. 85% of patients described their result as good to excellent. 80% would undergo the intervention again. During ultrasonography, distance from FPL to volar rim remained significantly decreased compared to the uninjured side in neutral and flexed position (p<0.05) despite plate removal. The largest distance between the FPL and the volar cortical bone, which is mainly occupied by the pronator quadratus, did not differ. In this study, the range of motion and FPL distance to the distal radius normalized only partially compared to the uninjured wrist after standard plate removal.Keywords
This publication has 17 references indexed in Scilit:
- Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar PlateThe Journal of Hand Surgery, 2017
- Relationship between plate removal and Soong grading following surgery for fractured distal radiusJournal of Hand Surgery (European Volume), 2017
- Midterm Follow-up of Treating Volar Marginal Rim Fractures with Variable Angle Lcp Volar Rim Distal Radius PlatesThe Journal of Hand Surgery (Asian-Pacific Volume), 2017
- Tendon Rupture and Tenosynovitis following Internal Fixation of Distal Radius Fractures: A Systematic ReviewPlastic and Reconstructive Surgery, 2017
- Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking platesActa Orthopaedica et Traumatologica Turcica, 2016
- Incidence of Hardware Removal Following Volar Plate Fixation of Distal Radius FractureThe Journal of Hand Surgery, 2015
- Complications following volar locking plate fixation for distal radial fractures: a systematic reviewJournal of Hand Surgery (European Volume), 2013
- Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius FractureClinics in Orthopedic Surgery, 2012
- Volar Locking Plate Implant Prominence and Flexor Tendon RuptureJournal of Bone and Joint Surgery, 2011
- PREVENTION OF FLEXOR POLLICIS LONGUS TENDON RUPTURE AFTER VOLAR PLATE FIXATION OF DISTAL RADIUS FRACTURESHand Surgery, 2011