Pieter-Bastiaan De Keyzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pieter-Bastiaan De Keyzer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jean Goubau
Department of Orthopaedics and Traumatology, University Hospital of Brussels, Laarbeeklaan 101, 1090 Brussel, Belgium; Department of Orthopaedics and Traumatology, AZ Maria Middelares, Buitenring-Sint-Denijs 30, 9000 Gent, Belgium
4 shared publications - Chul Ki Goorens
International Wrist Center (IWC) Tienen, Regionaal Ziekenhuis Tienen, Tienen, Belgium
3 shared publications - Michiel Cromheecke
AZ Maria Middelares, Buitenring-Sint-Denijs 30, 9000 Gent, Belgium; UZ Gent, Corneel Heymanslaan 10, 9000 Gent, Belgium
2 shared publications - Bert Vanmierlo
Department of Orthopaedics and Traumatology, AZ Delta, Roeselare, Belgium
1 shared publication - Joris Duerinckx
Department of Orthopaedic Surgery and Traumatology, Ziekenhuis Oost-Limburg, Genk, Belgium
1 shared publication - Kjell Van Royen
University Hospital Brussels, Vrije Universiteit Brussel, Brussels, Belgium
1 shared publication
Latest Publications
- 18 October 2025
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 44 (6) , 102304
Reprocessing Single-Use endoscopic knives: An innovative feasibility study
- 18 October 2025
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 44 (6) , 102304
Reprocessing Single-Use endoscopic knives: An innovative feasibility study
- 9 April 2025
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 44 (3) , 102156
Trapezial cup loosening in ball and socket prosthesis: Trapezium reconstruction using a structural iliac crest graft, technique and first results
- 9 April 2025
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 44 (3) , 102156
Trapezial cup loosening in ball and socket prosthesis: Trapezium reconstruction using a structural iliac crest graft, technique and first results
- 12 October 2020
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 31 (3) , 541-548
Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons—a randomized controlled study
The objective was to evaluate pronator quadratus (PQ) repair following volar plating of distal radial fractures on clinical and functional outcome, as well as flexor tendon friction, during the first 12 months in ideally positioned plates (Soong 0). Confounding factors like variation in plate positioning, anatomical consolidation of the fracture and associated lesions were excluded. Eighty patients were included with distal radius fractures treated by volar locking plate in Soong grade 0 position, who were randomized to group PQ repair and group no repair. Sixty-five patients completed the 1-year follow-up: group PQ repair (n = 35) and group no repair (n = 30). Primary outcomes included range of motion, grip strength, pain level and QuickDASH. Secondary outcomes included distance between flexor pollicis longus (FPL) and volar rim and the largest distance between FPL and plate (soft tissue thickness occupied by PQ), assessed by ultrasonography. Mobility, grip strength and QuickDASH revealed no significant differences, except extension was significantly higher only in first 3 months and radial deviation was significantly higher only at 6 weeks after PQ repair. Pain level was significantly lower after PQ repair only in the first 3 months. Distance between FPL and volar rim and the largest distance between FPL and plate were significantly higher after PQ repair. No friction contact between FPL and volar rim was measured in both groups at all measurement moments. Consequently, protective flexor tendon effect of PQ repair could consequently not be concluded. In conclusion, clinical and functional short term benefits, except improved wrist extension and reduced pain in the first 3 months, were not proven in this study. In Soong grade 0, PQ repair is probably not necessary to prevent flexor tendon pathology. In Soong grade 1 or 2, this is still to be investigated. Level of evidence 2.
- 12 October 2020
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 31 (3) , 541-548
Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons—a randomized controlled study
The objective was to evaluate pronator quadratus (PQ) repair following volar plating of distal radial fractures on clinical and functional outcome, as well as flexor tendon friction, during the first 12 months in ideally positioned plates (Soong 0). Confounding factors like variation in plate positioning, anatomical consolidation of the fracture and associated lesions were excluded. Eighty patients were included with distal radius fractures treated by volar locking plate in Soong grade 0 position, who were randomized to group PQ repair and group no repair. Sixty-five patients completed the 1-year follow-up: group PQ repair (n = 35) and group no repair (n = 30). Primary outcomes included range of motion, grip strength, pain level and QuickDASH. Secondary outcomes included distance between flexor pollicis longus (FPL) and volar rim and the largest distance between FPL and plate (soft tissue thickness occupied by PQ), assessed by ultrasonography. Mobility, grip strength and QuickDASH revealed no significant differences, except extension was significantly higher only in first 3 months and radial deviation was significantly higher only at 6 weeks after PQ repair. Pain level was significantly lower after PQ repair only in the first 3 months. Distance between FPL and volar rim and the largest distance between FPL and plate were significantly higher after PQ repair. No friction contact between FPL and volar rim was measured in both groups at all measurement moments. Consequently, protective flexor tendon effect of PQ repair could consequently not be concluded. In conclusion, clinical and functional short term benefits, except improved wrist extension and reduced pain in the first 3 months, were not proven in this study. In Soong grade 0, PQ repair is probably not necessary to prevent flexor tendon pathology. In Soong grade 1 or 2, this is still to be investigated. Level of evidence 2.
- 1 October 2020
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 30 (7) , 1215-1219
Clinical and ultrasonographical follow-up after standard removal of distal radius volar plates positioned distal to the watershed line
Marginal fracture types of the distal radius may require volar plate positioning distal to the watershed line. Subsequently, plate prominence with direct friction with the flexor tendons occurs which is associated with flexor tendon pathology. Standard plate removal can be proposed. This cohort study examined clinical outcome, patient satisfaction and ultrasonographical assessment of the relation of the flexor pollicis longus (FPL) and the volar rim after standard plate removal. Twenty patients with volar plate prominence after osteosynthesis for distal radius fractures were included. Plate removal was performed at least 4 months after initial surgery. The mean age was 60 years (range 39-84). The average delay from hardware removal to assessment was 2.9 years (range 1.0-5.0 years). Mean flexion, extension and radial deviation were significantly decreased (p<0.05) compared to the contralateral side, while ulnar deviation, pro- and supination and grip strength were not. Mean QuickDASH score was 21.5. 85% of patients described their result as good to excellent. 80% would undergo the intervention again. During ultrasonography, distance from FPL to volar rim remained significantly decreased compared to the uninjured side in neutral and flexed position (p<0.05) despite plate removal. The largest distance between the FPL and the volar cortical bone, which is mainly occupied by the pronator quadratus, did not differ. In this study, the range of motion and FPL distance to the distal radius normalized only partially compared to the uninjured wrist after standard plate removal.
- 1 October 2020
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 30 (7) , 1215-1219
Clinical and ultrasonographical follow-up after standard removal of distal radius volar plates positioned distal to the watershed line
Marginal fracture types of the distal radius may require volar plate positioning distal to the watershed line. Subsequently, plate prominence with direct friction with the flexor tendons occurs which is associated with flexor tendon pathology. Standard plate removal can be proposed. This cohort study examined clinical outcome, patient satisfaction and ultrasonographical assessment of the relation of the flexor pollicis longus (FPL) and the volar rim after standard plate removal. Twenty patients with volar plate prominence after osteosynthesis for distal radius fractures were included. Plate removal was performed at least 4 months after initial surgery. The mean age was 60 years (range 39-84). The average delay from hardware removal to assessment was 2.9 years (range 1.0-5.0 years). Mean flexion, extension and radial deviation were significantly decreased (p<0.05) compared to the contralateral side, while ulnar deviation, pro- and supination and grip strength were not. Mean QuickDASH score was 21.5. 85% of patients described their result as good to excellent. 80% would undergo the intervention again. During ultrasonography, distance from FPL to volar rim remained significantly decreased compared to the uninjured side in neutral and flexed position (p<0.05) despite plate removal. The largest distance between the FPL and the volar cortical bone, which is mainly occupied by the pronator quadratus, did not differ. In this study, the range of motion and FPL distance to the distal radius normalized only partially compared to the uninjured wrist after standard plate removal.