Objective . Magneto-acousto-electrical tomography (MAET) based on nonlinearly frequency-modulated (NLFM) signal stimulation achieves large dynamic range of detection while sacrifices a little longitudinal resolution (LR). However, NLFM signal stimulation is also negatively affected by the uneven frequency response in MAET, which results in widening of the main lobe width after pulse compression and ultimately leads to the degradation of LR in the MAET images. To further improve the LR of the MAET using NLFM signal stimulation, an MAET method using frequency-response-compensated nonlinearly frequency-modulated (FRC-NLFM) signal stimulation is proposed. Approach . Two types of nonlinear frequency-time curves are generated using the window function method and the piecewise linear frequency modulation method. The cubic spline interpolation method is employed to fit the nonlinear frequency response curves, which are used to generate the FRC-NLFM stimulation signals. Four groups of MAET experiments using respectively pure agar phantom samples and an in vitro multi-layer pork tissue agar phantom sample are conducted. Comparisons in terms of sensitivity, LR and dynamic range of detection are made among MAET using respectively spike, FRC-LFM, FRC-NLFM, and purely NLFM stimulation methods. Main results . MAET using FRC-NLFM stimulation improves LR over MAET using purely NLFM excitation, and has higher sensitivity and larger dynamic range over MAET based on FRC-LFM. Significance . This method forwards coded-excitation-based MAET to become an imaging method with high sensitivity, high LR and large dynamic range, and paves another way for the clinical application of the MAET.Keywords
Funding Information
- National Natural Science Foundation of China (62001013)
- Beijing Natural Science Foundation (7262218)
This publication has 38 references indexed in Scilit:
- Magneto-acousto-electrical tomography utilizing line-shaped acoustic beamsApplied Acoustics, 2025
- Enhancing Imaging Performance and Resolution in Magneto‐Acoustic Electrical Tomography With Magnetic Field Measurements ( MAET ‐ MI ) Using Figure‐of‐Eight and High‐Quality Factor Circular CoilsInternational Journal for Numerical Methods in Biomedical Engineering, 2025
- Analyzing Pulse Compression Performance and Image Quality Metrics of Different Excitations in MAET With Magnetic Field MeasurementsInternational Journal for Numerical Methods in Biomedical Engineering, 2024
- Three-dimensional magneto-acousto-electrical tomography (3D MAET) with single-element ultrasound transducer and coded excitation: A phantom validation studyNeurocomputing, 2023
- General principle and optimization of magneto‐acousto‐electrical tomography based on image distortion evaluationMedical Physics, 2023
- Magneto-acoustic-electrical tomography combining maximum length sequence–coded excitation and liquid metal image contrast agentUltrasound in Medicine & Biology, 2022
- Image quality improvement of magneto-acousto-electrical tomography with Barker coded excitationBiomedical Signal Processing and Control, 2022
- Variation in dielectric properties due to pathological changes in human liverBioelectromagnetics, 2015
- A mathematical and numerical framework for ultrasonically-induced Lorentz force electrical impedance tomographyJournal de Mathématiques Pures et Appliquées, 2015
- Lorentz force electrical impedance tomographyIRBM, 2013