ZSZhishen Sun

Zhishen Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhishen Sun has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Kebin Jia

    Department of Information and Communication Engineering, School of Information Science and Technology, Beijing University of Technology

    3 shared publications
  • Guoqiang Liu

    Institute of Electrical Engineering, Chinese Academy of Sciences

    2 shared publications
  • Jian-Fei Wang

    Beijing Key Laboratory of Nonlinear Vibrations and Strength of Mechanical Structures, Beijing University of Technology

    2 shared publications
  • Jianfei Wang

    Beijing Univ Technol, Sch Math Stat & Mech, Beijing Key Lab Nonlinear Vibrat & Strength Mech S, Beijing 100124, Peoples R China

    2 shared publications
  • Meijia Li

    Department of Information and Communication Engineering, School of Information Science and Technology, Beijing University of Technology

    2 shared publications
  • Stefan Catheline

    LabTAU, INSERM, Centre Léon Bérard 1 , Université Claude Bernard Lyon 1, F-69003 LYON

    2 shared publications

Latest Publications

  • Magneto-acousto-electrical tomography using frequency-response-compensated nonlinearly frequency-modulated stimulation

    by Zhishen Sun, Jinfu Liu, Meijia Li, Zhizhuo Cheng, Jianfei Wang, Kebin Jia

    Objective . Magneto-acousto-electrical tomography (MAET) based on nonlinearly frequency-modulated (NLFM) signal stimulation achieves large dynamic range of detection while sacrifices a little longitudinal resolution (LR). However, NLFM signal stimulation is also negatively affected by the uneven frequency response in MAET, which results in widening of the main lobe width after pulse compression and ultimately leads to the degradation of LR in the MAET images. To further improve the LR of the MAET using NLFM signal stimulation, an MAET method using frequency-response-compensated nonlinearly frequency-modulated (FRC-NLFM) signal stimulation is proposed. Approach . Two types of nonlinear frequency-time curves are generated using the window function method and the piecewise linear frequency modulation method. The cubic spline interpolation method is employed to fit the nonlinear frequency response curves, which are used to generate the FRC-NLFM stimulation signals. Four groups of MAET experiments using respectively pure agar phantom samples and an in vitro multi-layer pork tissue agar phantom sample are conducted. Comparisons in terms of sensitivity, LR and dynamic range of detection are made among MAET using respectively spike, FRC-LFM, FRC-NLFM, and purely NLFM stimulation methods. Main results . MAET using FRC-NLFM stimulation improves LR over MAET using purely NLFM excitation, and has higher sensitivity and larger dynamic range over MAET based on FRC-LFM. Significance . This method forwards coded-excitation-based MAET to become an imaging method with high sensitivity, high LR and large dynamic range, and paves another way for the clinical application of the MAET.

  • Robust flexural wave energy harvesting via topologically protected interface modes of defect-enhanced performance in a phononic crystal beam-foundation system

    by Jianfei Wang, Xinyi Yang, Zhishen Sun, Zhenyu Chen, Dongxing Cao

    Topologically protected interface modes offer a novel approach to concentrate vibration energy in the structural interfaces with robustness to defects and disorders preserved, but seldom validated via high-frequency experiment. This paper proposes a flexural wave energy harvester driven by nanoscale-amplitude excitations, and both characterized via numerical simulation and ultrasonic experiment to verify the robust harvesting and defect-enhanced voltage output. The band structures and topological phase transitions are investigated in the designed elastically supported phononic crystal (PnC) beam. The band crossing point is shifted from 2670 Hz to 3982 Hz by an added elastic support, and then transformed to an extra bandgap by the adjustment of rubber pillar distance. The flexural wave energy at the interface of two substructures are converted into the electrical energy via piezoelectric disc efficiently. Specifically, the introduction of section defects and spring disorder highlight the exceptional topological robustness to preserve energy harvesting performance. A novel and feasible route about intelligent control is provided to actively tune the operational frequency by adjusting the support spring stiffness. Compared to the plain beam, the topological beam yields 11.51 and 9.19 times higher output voltages with and without section defects, respectively, which indicates the reliable high-performance design strategy of defect-tolerant PnC energy harvesters. Studies demonstrate that rather than acting as limitations, designed defects can be strategically exploited to enhance localization and thereby improve energy harvesting.

  • Magneto-acousto-electrical tomography based on frequency response compensated linearly frequency-modulated signal stimulation

    by Meijia Li, Jianfei Wang, Kebin Jia, Zhishen Sun

    Objective. In magneto-acousto-electrical tomography (MAET), linearly frequency-modulated (LFM) signal stimulation uses much lower peak voltage than the spike pulse stimulation, lengthening the operation life of the transducer. However, due to the uneven frequency responses of the transducer, the low-noise amplifier (LNA), and the bandpass filter (BPF), MAET using LFM signal stimulation suffers from longitudinal resolution loss. In this paper, frequency response compensated linearly frequency-modulated (FRC-LFM) signal stimulation is investigated to resolve the problem. Approach. The physical model of measurement of the frequency responses of the transducer and the cascading module of the detection electrodes, the LNA, and the BPF is constructed. The frequency responses are approximated by fitting a curve to the measurement data. The frequency response compensation function is set to the reciprocal of the product of the frequency responses. The digital FRC-LFM signal is generated in MATLAB and converted to analog signal through an arbitrary waveform generator. Two groups of MAET experiments are designed to confirm the performance of the FRC-LFM signal stimulation. Pure agar phantom with rectangular through-holes and agar phantom with pork tissue inclusion serve as the samples. Main results. The pulse-compressed magneto-acousto-electrical signal obtained using FRC-LFM stimulation has narrower main-lobe than that obtained using LFM excitation, although the signal to noise pulse interference ratio of the former is little lower than that of the latter, which is due to the limitation of the power amplifier. FRC-LFM also proves to be an effective method to utilize the frequency outside the working band of the transducer in MAET. Significance. The method in this study compensates for the longitudinal resolution loss due to the uneven frequency responses. Combining with high-capability power amplifier and high-performance LNA, the MAET using FRC-LFM signal stimulation can potentially achieve high longitudinal resolution and high sensitivity, advancing MAET toward the clinical application.


  • Magneto-acousto-electrical tomography using nonlinearly frequency-modulated ultrasound

    by Zhizhuo Cheng, Zhishen Sun, Jianfei Wang, Kebin Jia

    Objective . In this study, nonlinearly frequency-modulated (NLFM) ultrasound was applied to magneto-acousto-electrical tomography (MAET) to increase the dynamic range of detection. Approach . Generation of NLFM signals using window function method—based on the principle of stationary phase—and piecewise linear frequency modulation method—based on the genetic algorithm—was discussed. The MAET experiment systems using spike, linearly frequency-modulated (LFM), or NLFM pulse stimulation were constructed, and three groups of MAET experiments on saline agar phantom samples were carried out to verify the performance—respectively the sensitivity, the dynamic range, and the longitudinal resolution of detection—of MAET using NLFM ultrasound in comparison to that using LFM ultrasound. Based on the above experiments, a pork sample was imaged by ultrasound imaging method, spike MAET method, LFM MAET method, and NLFM MAET method, to compare the imaging accuracy. Main results . The experiment results showed that, through sacrificing very little main-lobe width of pulse compression or equivalently the longitudinal resolution, the MAET using NLFM ultrasound achieved higher signal-to-interference ratio (and therefore higher detection sensitivity), lower side-lobe levels of pulse compression (and therefore larger dynamic range of detection), and large anti-interference capability, compared to the MAET using LFM ultrasound. Significance . The applicability of the MAET using NLFM ultrasound was proved in circumferences where sensitivity and dynamic range of detection were mostly important and slightly lower longitudinal resolution of detection was acceptable. The study furthered the scheme of using coded ultrasound excitation toward the clinical application of MAET.


  • Shear Wave Generation by Remotely Stimulating Aluminum Patches With a Transient Magnetic Field and Its Preliminary Application in Elastography

    by Zhishen Sun, Bruno Giammarinaro, Alain Birer, Guoqiang Liu, Stefan Catheline

    Objective: This article presents shear wave generation by remotely stimulating aluminum patches through a transient magnetic field, and its preliminary application in the cross-correlation approach based ultrasound elastography. Methods: A transient magnetic field is employed to remotely vibrate the patch actuators through the Lorentz force. The origin, and the characteristics of the Lorentz force are confirmed using an interferometric laser probe. The shear wave displacement fields generated in the soft medium are studied through the ultrafast ultrasound imaging. The potential of the shear wave fields generated through the patch actuators for the cross-correlation approach based elastography is confirmed through experiments on an agar phantom sample. Results: Under a transient magnetic field of changing rate of 10.44 kT/s, the patch actuator generates a shear wave source of amplitude of 100 μm in a polyvinyl alcohol (PVA) phantom sample. The shear wave fields created by experiments agree qualitatively well with those by theory. From the shear wave velocity map computed from 100 frames of shear wave fields, the boundaries of cylindrical regions of different stiffness can be clearly recognized, which are completely concealed in the ultrasound image. Conclusion: Shear wave fields in the level of 100 μm can be remotely generated in soft medium through stimulating aluminum patches with a transient magnetic field, and qualitative shear wave velocity maps can be reconstructed from the shear wave fields generated. Significance: The proposed method allows potential application of the cross-correlation approach based elastography in intravascular-based or catheter-based cardiology.


  • Lorentz Force Electrical-Impedance Tomography Using Linearly Frequency-Modulated Ultrasound Pulse

    by Zhishen Sun, Guoqiang Liu, Hui Xia, Stefan Catheline

    Lorentz force electrical impedance tomography (LFEIT) combines ultrasound stimulation and electromagnetic field detection with the goal of creating a high contrast and high resolution hybrid imaging modality. To reduce the peak stimulation power to the ultrasound transducer in LFEIT, linearly frequency-modulated ultrasound pulse was investigated in this work. First, the coherency between linearly frequency-modulated ultrasound excitation and the resulting local current density was established theoretically. Then, experiments were done using different agar phantoms of conductivity ranging from 0.2 S/m to 0.5 S/m. The results showed: (1) using electrical signal of peak instantaneous power of 39.54 dBm to the ultrasound transducer, which was 25.5 dB lower than the peak instantaneous power of the high-voltage narrow pulse adopted in traditional LFEIT (65.05 dBm), the linearly frequency-modulated ultrasound pulse based LFEIT can detect the electrical conductivity discontinuity positions precisely; (2) the reconstructed B-scan image of the electrical conductivity discontinuity distribution is comparable to that obtained through LFEIT with high-voltage narrow pulse; (3) axial resolution of 1 mm was achieved with the experimental setup. The method of linearly frequency-modulated ultrasound pulse stimulation and coherent detection initiates an alternative scheme towards the clinical application of LFEIT.