Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking
- 1 March 2000
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 18 (2) , 195-202
Abstract
This research provides a detailed analysis of the kinematics of passive elbow motion. It quantifies how closely humeroulnar kinematics approximates rotation around a fixed axis. The results are clinically relevant for emerging treatment modalities that impose an artificial hinge to the elbow joint, such as total elbow arthroplasty and articulated external fixation. In a cadaveric study of seven specimens, we quantified ulnar rotation around the humerus in terms of instantaneous screw displacement axes calculated from electromagnetic motion‐tracking source data. This methodology enabled description of the complex excursion of the elbow axis in terms of translation and orientation changes of the screw displacement axes over the range of motion. Furthermore, we analyzed the envelope of joint laxity for elbow motion under applied small varus and valgus moments. In addition, radiographic landmarks of clinical utility for axis location were evaluated by visualizing the elbow's radiographic appearance when viewed from along the calculated best‐fit (average) rotation axis. Over the normal range of elbow motion, the screw displacement axis varied 2.6–5.7° in orientation and 1.4–2.0 mm in translation. All instantaneous rotation axes nearly intersected on the medial facet of the trochlea. The breadth of the envelope of varus‐valgus joint laxity was greatest within the initial 40° of flexion and decreased by a factor of approximately two for flexion angles exceeding 100°.Keywords
This publication has 13 references indexed in Scilit:
- Factors Influencing Accuracy of Screw Displacement Axis Detection With a D.C.-Based Electromagnetic Tracking SystemJournal of Biomechanical Engineering, 1998
- Kinematics and Laxity of Ulnohumeral Joint Under Valgus-Varus StressJournal of Musculoskeletal Research, 1998
- Accuracy of an electromagnetic tracking device: A study of the optimal operating range and metal interferenceJournal of Biomechanics, 1996
- Variation of muscle moment arms with elbow and forearm positionJournal of Biomechanics, 1995
- BIOMECHANICS OF THE ELBOW AND FOREARMHand Clinics, 1994
- Distraction Arthroplasty Clinical ApplicationsClinical Orthopaedics and Related Research, 1993
- Kinematics and stability of the Norway elbow: A cadaveric studyActa Orthopaedica, 1993
- Application of a magnetic tracking device to kinesiologic studiesJournal of Biomechanics, 1988
- Biomechanical Basis for Elbow Hinge-Distractor DesignClinical Orthopaedics and Related Research, 1987
- Passive motion of the elbow jointJournal of Bone and Joint Surgery, 1976