A 206 μW Vital Signs Monitoring System on Chip for Measuring Five Vitals
- 24 June 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 32 (9) , 1652-1660
Abstract
This article presents an area and power-efficient system-on-chip (SoC) for vital signs monitoring to provide patients with remote monitoring. It measures five important vitals including blood oxygen saturation (SpO2), respiration rate (RR), heart rate (HR), HR variability (HRV), and temperature. The proposed SoC utilizes a photoplethysmography (PPG) signal to compute HR, HRV, SpO2, and RR. The PPG signal is amplified and filtered using a PPG readout that includes a transimpedance amplifier (TIA) with a switched integrator (SI) to filter and amplify the signal. A differential second-order, delta-sigma analog-to-digital converter ( $\Delta \Sigma $ -ADC) is adopted to digitize the PPG signal. The SoC also comprises a low-power LED driver for both red and infrared (IR) LEDs which operate in pulsed mode with a 0.625% duty cycle. A vital signs extractor performs feature extraction (FE) and computes the vital signs with a maximum absolute error of less than 1%. In this work, the temperature is also measured by employing a Wheatstone bridge (WhB)-based temperature sensor which integrates thermal resistors into a second-order $\Delta \Sigma $ -ADC. The proposed system shares $\Delta \Sigma $ -ADC for digitizing the PPG signal and the temperature readings to reduce both area and power consumption. The proposed system computes the temperature over the human’s temperature range ( $32~^{\circ }$ C to $42~^{\circ }$ C) with an accuracy of +/ $- 0.09~^{\circ }$ C. The SoC is implemented using a 180 nm CMOS process with an area of 4.8 mm2 while consuming $206~\mu $ W.
Keywords
Funding Information
- Engineering and Design Department at Western Washington University
- Islamic Development Bank
This publication has 40 references indexed in Scilit:
- Ambient Light-Driven Wireless Wearable Finger Patch for Monitoring Vital Signs From PPG SignalIEEE Sensors Journal, 2023
- A Signal Quality Index for Improving the Estimation of Breath-by-Breath Respiratory Rate During Sport and ExerciseIEEE Sensors Journal, 2023
- A Wireless Low-Power Single-Unit Wearable System for Continuous Early Warning Score CalculationIEEE Sensors Journal, 2023
- Robust Respiratory Rate Monitoring Using Smartwatch PhotoplethysmographyIEEE Internet of Things Journal, 2022
- Robust Estimation of Respiratory Rate from Photoplethysmogram with Respiration Quality Analysis2022
- A 385μW Photoplethysmography-based Vitals Monitoring SoC with 110dB Current-to-Digital Converter2022
- Wearable Multimodal Vital Sign Monitoring Sensor With Fully Integrated Analog Front EndIEEE Sensors Journal, 2022
- 28.3 A 28μW 134dB DR 2 nd -Order Noise-Shaping Slope Light-to-Digital Converter for Chest PPG Monitoring2021
- A 1mW Vitals Monitoring System for Asthmatic Patients based on Photoplethysmography2019
- Low-Power Wearable Systems for Continuous Monitoring of Environment and Health for Chronic Respiratory DiseaseIEEE Journal of Biomedical and Health Informatics, 2016