WSWala Saadeh

Wala Saadeh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wala Saadeh has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Saber With Hybrid Striding Toom Cook-Based Multiplier: Implementation Using Open-Source Tool Flow and Industry Standard Chip Design Tools

    by Muhammad Naveed Abbasi, Abdul Rehman Aslam, Muhammad Awais Bin Altaf, Wala Saadeh

    Quantum computers are a significant threat to the existing cryptography algorithms. The Saber is a lattice-based post-quantum cryptographic or quantum-safe algorithm designed as a quantum computing attack-resistant protocol. The hardness of SABER is based on the Rounding with Learning (LWR) problem. This work presents a hardware implementation of Striding Toom Cook multiplier-based Saber. SABER is selected algorithms of the NIST (National Institute of Standards and Technology) round 3 criteria. After evaluation in the striding school book multiplier, a technique is also introduced to efficiently load the weighted polynomials into registers and multipliers. The implemented design is realized utilizing Cadence digital-flow (industry-standard) and open-source tool flow (OFRS) with CMOS 180nm TSMC and CMOS (130nm/180nm SKY-WATER) process, respectively. The realized chip for the proposed Saber implementation resulted in an area of 12 mm 2 and 43.59 mm 2 /16 mm 2 for TSMC CMOS 180nm and SKY-WATER CMOS 180nm/130nm process, respectively. This implementation provided roughly equal latency for Key encryption, decryption, and Key generation when compared to a state-of-the-art design which utilized different techniques for polynomial multiplication whereas this design utilized 2X, 2X, and 2.5X lesser clock cycles required for Key generation, Key encryption, and decryption, respectively, compared to Saber implementation utilizing Striding Toom cook based multiplier for polynomial multiplication.

  • Open Access

    A Closed-Loop Ear-Worn Wearable EEG System with Real-Time Passive Electrode Skin Impedance Measurement for Early Autism Detection

    by Muhammad Sheeraz, Abdul Rehman Aslam, Emmanuel Mic Drakakis, Hadi Heidari, Muhammad Awais Bin Altaf, Wala Saadeh

    Autism spectrum disorder (ASD) is a chronic neurological disorder with the severity directly linked to the diagnosis age. The severity can be reduced if diagnosis and intervention are early (age < 2 years). This work presents a novel ear-worn wearable EEG system designed to aid in the early detection of ASD. Conventional EEG systems often suffer from bulky, wired electrodes, high power consumption, and a lack of real-time electrode–skin interface (ESI) impedance monitoring. To address these limitations, our system incorporates continuous, long-term EEG recording, on-chip machine learning for real-time ASD prediction, and a passive ESI evaluation system. The passive ESI methodology evaluates impedance using the root mean square voltage of the output signal, considering factors like pressure, electrode surface area, material, gel thickness, and duration. The on-chip machine learning processor, implemented in 180 nm CMOS, occupies a minimal 2.52 mm² of active area while consuming only 0.87 µJ of energy per classification. The performance of this ML processor is validated using the Old Dominion University ASD dataset.


  • Epileptic Seizure Detection and Prediction for Patient Support

    by Gul Hameed Khan, Nadeem Ahmad Khan, Wala Saadeh, Muahammad Awais Bin Altaf

  • A 206 μW Vital Signs Monitoring System on Chip for Measuring Five Vitals

    by Sameen Minto, Austin Cable, Wala Saadeh

    This article presents an area and power-efficient system-on-chip (SoC) for vital signs monitoring to provide patients with remote monitoring. It measures five important vitals including blood oxygen saturation (SpO2), respiration rate (RR), heart rate (HR), HR variability (HRV), and temperature. The proposed SoC utilizes a photoplethysmography (PPG) signal to compute HR, HRV, SpO2, and RR. The PPG signal is amplified and filtered using a PPG readout that includes a transimpedance amplifier (TIA) with a switched integrator (SI) to filter and amplify the signal. A differential second-order, delta-sigma analog-to-digital converter ( $\Delta \Sigma $ -ADC) is adopted to digitize the PPG signal. The SoC also comprises a low-power LED driver for both red and infrared (IR) LEDs which operate in pulsed mode with a 0.625% duty cycle. A vital signs extractor performs feature extraction (FE) and computes the vital signs with a maximum absolute error of less than 1%. In this work, the temperature is also measured by employing a Wheatstone bridge (WhB)-based temperature sensor which integrates thermal resistors into a second-order $\Delta \Sigma $ -ADC. The proposed system shares $\Delta \Sigma $ -ADC for digitizing the PPG signal and the temperature readings to reduce both area and power consumption. The proposed system computes the temperature over the human’s temperature range ( $32~^{\circ }$ C to $42~^{\circ }$ C) with an accuracy of +/ $- 0.09~^{\circ }$ C. The SoC is implemented using a 180 nm CMOS process with an area of 4.8 mm2 while consuming $206~\mu $ W.


  • Open Access

    Continuous Patient-Independent Estimation of Respiratory Rate and Blood Pressure Using Robust Spectro-Temporal Features Derived From Photoplethysmogram Only

    by Muhammad Ahmad Sultan, Wala Saadeh

    Objective: A patient-independent approach for continuous estimation of vital signs using robust spectro-temporal features derived from only photoplethysmogram (PPG) signal. Methods: In the pre-processing stage, we remove baseline shifts and artifacts of the PPG signal using Incremental Merge Segmentation with adaptive thresholding. From the cleaned PPG, we extract multiple parameters independent of individual patient PPG morphology for both Respiration Rate (RR) and Blood Pressure (BP). In addition, we derived a set of novel spectral and statistical features strongly correlated to BP. We proposed robust correlation-based feature selection methods for accurate RR estimates. For fewer computations and accurate measurements of BP, the most significant features are selected using correlation and mutual information measures in the feature engineering part. Finally, RR and BP are estimated using breath counting and a neural network regression model, respectively. Results: The proposed approach outperforms the current state-of-the-art in both RR and BP. The RR algorithm results in mean absolute errors (median, 25th-75th percentiles) of 0.4 (0.1-0.7) for CapnoBase dataset and 0.5(0.3-2.8) for BIDMC dataset without discarding any data window. Similarly, BP approach has been validated on a large dataset derived from MIMIC-II ( $\sim$ 1700 records) which has errors (mean absolute, standard deviation) of 5.0(6.3) and 3.0(4.0) for systolic and diastolic BP, respectively. The results meet the American Association for the Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) Class A criteria. Conclusion: By using robust features and feature selection methods, we alleviated patient dependency to have reliable estimates of vitals.


  • Open Access

    Monitoring Level of Hypnosis Using Stationary Wavelet Transform and Singular Value Decomposition Entropy With Feedforward Neural Network

    by Muhammad Ibrahim Dutt, Wala Saadeh

    Objective : Classifying the patient’s depth of anesthesia (LoH) level into a few distinct states may lead to inappropriate drug administration. To tackle the problem, this paper presents a robust and computationally efficient framework that predicts a continuous LoH index scale from 0-100 in addition to the LoH state. Methods: This paper proposes a novel approach for accurate LoH estimation based on Stationary Wavelet Transform (SWT) and fractal features. The deep learning model adopts an optimized temporal, fractal, and spectral feature set to identify the patient sedation level irrespective of age and the type of anesthetic agent. This feature set is then fed into a multilayer perceptron network (MLP), a class of feed-forward neural networks. A comparative analysis of regression and classification is made to measure the performance of the chosen features on the neural network architecture. Results: The proposed LoH classifier outperforms the state-of-the-art LoH prediction algorithms with the highest accuracy of 97.1% while utilizing minimized feature set and MLP classifier. Moreover, for the first time, the LoH regressor achieves the highest performance metrics (R 2 = 0.9, MAE = 1.5) as compared to previous work. Significance: This study is very helpful for developing highly accurate monitoring for LoH which is important for intraoperative and postoperative patients’ health.


  • A 380-μW Electrochemical Impedance Measurement System for Protein Sensing

    by Muhammad Rizwan Khan, Rameesha Qaiser, Wala Saadeh

    Diagnostic testing plays an important role in modern medicine, helping physicians make informed decisions regarding disease diagnosis and treatment. Proteins’ biomarkers are utilized to detect disease onset, progression, efficacy of medicines, and patient susceptibility to get a specific kind of disease. Electrochemical impedance spectroscopy (EIS) is likely to underpin the progressive drive toward sensitive, miniaturized, and portable biomarker detection practices. The EIS is a highly sensitive detection method adopted to find the electrical response of chemical samples by applying low amplitude ac voltages/currents with tunable frequency. Conventional EIS systems use mixers and lock-in amplifiers to find both the real and imaginary components of the complex impedance. In this article, we present a partially integrated EIS measurement system to find the impedance of a biological sample. It includes a programmable sine-wave synthesizer (SWS) block with a frequency range of 500 $\mu$ Hz to 100 kHz. The implementation is based on switched-capacitor filters that adjust the cutoff frequency by changing the clock. The sample impedance is measured through mostly digital magnitude and phase-detection blocks. The proposed EIS system is realized using a 0.18- $\mu$ m technology with a 0.35-mmTEXPRESERVE3 active area and 380- $\mu$ W power consumption. The proposed magnitude detection archives a differential nonlinearity (DNL) performance of $-$ 0.34/ $+$ 0.3 LSB and an integral nonlinearity (INL) of $-$ 0.75/ $+$ 2 LSB. The system is used to measure the impedance of biological samples containing tumor necrosis factor alpha (TNF- $\alpha)$ protein at variable concentrations.


  • Top Cited Papers
    Open Access

    Noninvasive Blood Glucose Monitoring Systems Using Near-Infrared Technology—A Review

    by Aminah Hina, Wala Saadeh

    The past few decades have seen ongoing development of continuous glucose monitoring (CGM) systems that are noninvasive and accurately measure blood glucose levels. The conventional finger-prick method, though accurate, is not feasible for use multiple times a day, as it is painful and test strips are expensive. Although minimally invasive and noninvasive CGM systems have been introduced into the market, they are expensive and require finger-prick calibrations. As the diabetes trend is high in low- and middle-income countries, a cost-effective and easy-to-use noninvasive glucose monitoring device is the need of the hour. This review paper briefly discusses the noninvasive glucose measuring technologies and their related research work. The technologies discussed are optical, transdermal, and enzymatic. The paper focuses on Near Infrared (NIR) technology and NIR Photoplethysmography (PPG) for blood glucose prediction. Feature extraction from PPG signals and glucose prediction with machine learning methods are discussed. The review concludes with key points and insights for future development of PPG NIR-based blood glucose monitoring systems.


  • A 186μW Photoplethysmography-Based Noninvasive Glucose Sensing SoC

    by Aminah Hina, Wala Saadeh

    Recent trends in research and the market show high demand for frequent monitoring of glucose to estimate the blood sugar level non-invasively which can replace the conventional finger-prick glucometer for daily use. This paper presents a high precision near-infrared Photoplethysmography (PPG) based noninvasive glucose monitoring System on Chip (SoC). The proposed system implements a fully differential Analog Frontend (AFE) with nonlinear medium Gaussian support-vector-regression (NMG-SVR) for glucose estimation. The AFE design incorporates chopping which enables the reduction of the integrated input-referred current noise to 9.4pArms thus achieving a dynamic range of 115dB. The glucose prediction processor (GPP) removes noise from the PPG signal, extracts ten unique features, and estimates the blood glucose level using a trained customized NMG-SVR model that minimizes the hardware cost by 25%. The extracted features are carefully designed and implemented to ensure inter-feature dependency, which helps to reduce the overall area by more than 40%. Moreover, GPP is implemented using power and clock gating techniques to minimize both static and dynamic power consumption. The proposed SoC is realized with $0.18~\mu \text{m}$ CMOS technology and occupies an area of 6 mm 2 . It dissipates a power of $186~\mu \text{W}$ and achieves a mean absolute relative difference (mARD) of 6.9% verified on 200 subjects.


  • An EEG-Based Hypnotic State Monitor for Patients During General Anesthesia

    by Fatima Hameed Khan, Wala Saadeh

    Most surgical procedures are not possible without general anesthesia which necessitates continuous and accurate monitoring of the patients' level of hypnosis (LoH). Currently, the LoH is monitored using the conventional methods of either observing the patient's physiological parameters or using electroencephalogram (EEG)-based monitors. To overcome the limitations of the conventional methods, this work implements an accurate EEG-based LoH monitoring processor using a bagged tree machine-learning (BTML) classifier. It is based on 12 temporal and spectral features to incorporate robustness against age variation and achieve high classification accuracy. Spectral features are computed using discrete wavelet transform (DWT) that uses time-multiplexed filter (TMF) architecture. The TMF DWT consumes 110.6-nJ/feature vector for a 100-tap filter while reducing the area by 11% compared with the conventional method. Moreover, the BTML is implemented using a pipelined approach which enables an efficient on-chip implementation to reduce the hardware cost by 15x compared with the parallel approach. The proposed processor is implemented using a 180-nm CMOS process with an active area of 0.9 mm² while consuming 1.6 mW. The accuracy of the proposed hypnotic state monitor is verified using two EEG databases with a total of 95 patients and achieves a sensitivity and specificity of 95.4% and 97.7%, respectively.