Optimizing Refractive Outcomes of SMILE: Artificial Intelligence versus Conventional State-of-the-Art Nomograms
- 30 November 2023
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 49 (3) , 252-259
Abstract
AI (artificial intelligence)-based methodologies have become established tools for researchers and physicians in the entire field of ophthalmology. However, the potential of AI to optimize the refractive outcome of keratorefractive surgery by means of machine learning (ML)-based nomograms has not been exhausted yet. In this study, we wanted to comprehensively compare state-of-the-art conventional nomograms for Small-Incision-Lenticule-Extraction (SMILE) with a novel ML-based nomogram regarding both their spherical and astigmatic predictability. A total of 1,342 eyes were analyzed for creation of three different nomograms based on a linear model (LM), a generalized additive mixed model (GAMM) and an artificial-neuronal-network (ANN), respectively. A total of 16 patient- and treatment-related features were included. Each model was trained by 895 eyes and validated by the remaining 447 eyes. Predictability was assessed by the difference between attempted and achieved change in spherical equivalent (SE) and the difference between target induced astigmatism (TIA) and surgically induced astigmatism (SIA). The root mean squared error (RMSE) of each model was computed as a measure of overall model performance. The RMSE of LM, GAMM and ANN were 0.355, 0.348 and 0.367 for the prediction of SE and 0.279, 0.278 and 0.290 for the astigmatic correction, respectively. By applying the created models, the theoretical yield of eyes within ±0.50 D of SE from target refraction improved from 82 to 83% (LM), 84% (GAMM) and 83% (ANN), respectively. Astigmatic outcomes showed an improvement of eyes within ±0.50 D from TIA from 90 to 93% (LM), 93% (GAMM) and 92% (ANN), respectively. Subjective manifest refraction was the single most influential covariate in all models. Machine learning endorsed the validity of state-of-the-art linear and non-linear SMILE nomograms. However, improving the accuracy of subjective manifest refraction seems warranted for optimizing ±0.50 D SE predictability beyond an apparent methodological 90% limit.Keywords
This publication has 24 references indexed in Scilit:
- The art of nomogramsEye and Vision, 2018
- A Nomogram to Improve Predictability of Small-Incision Lenticule Extraction SurgeryMedical Science Monitor, 2017
- Small incision lenticule extraction (SMILE) monovision for presbyopia correctionEuropean Journal of Ophthalmology, 2017
- Corneal power evaluation after myopic corneal refractive surgery using artificial neural networksBioMedical Engineering OnLine, 2016
- Evaluation of a Machine-Learning Classifier for Keratoconus Detection Based on Scheimpflug TomographyCornea, 2016
- Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomesEye and Vision, 2014
- Verbesserung der refraktiven Ergebnisse durch NomogrammeDer Ophthalmologe, 2006
- Practical astigmatism analysis for refractive outcomes in cataract and refractive surgerySurvey of Ophthalmology, 2004
- Inference in Generalized Additive Mixed Models by Using Smoothing SplinesJournal of the Royal Statistical Society Series B: Statistical Methodology, 1999
- Neural network computer program to determine photorefractive keratectomy nomogramsJournal of Cataract & Refractive Surgery, 1998