NMNiklas Mohr

Niklas Mohr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Niklas Mohr has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Inter-expert agreement on epithelial thickness mapping for refractive surgery screening: variability highlights need for standardization

    by Niklas Mohr, Jorge L. Alio del Barrio, Martin Dirisamer, Alain Saad, Stefan Kassumeh, Wolfgang J. Mayer, Siegfried G. Priglinger, Nikolaus Luft

    Purpose: To evaluate inter-expert agreement on epithelial thickness map interpretation and its influence on eligibility decisions for keratorefractive surgery candidates. Setting: Multicenter international collaboration involving four experienced refractive surgeons. Design: Retrospective, masked case review study. Methods: A total of 103 cases were retrospectively evaluated, including patients with normal (n=44), borderline (n=44), and keratoconic (n=15) corneal tomography, as defined by the Belin-Ambrosio-Display (BAD). Four independent experts (MD, JA, AS, NL) first assessed surgical eligibility based on Scheimpflug tomography and subsequently re-evaluated the same cases with the addition of anterior segment OCT–based epithelial thickness maps. To ensure comparability, a standardized questionnaire with nine predefined epithelial thickness characteristics was used. Inter-rater agreement was quantified with Fleiss’ kappa (κ), and the relative impact of each imaging modality on decision-making was ranked. Results: Incorporating epithelial mapping changed the eligibility decision in 19% (77 / 412) of cases. Specifically, 9% (16 / 176) of normal, 20% (35 / 176) of borderline, and 3% (2 / 60) of keratoconic cases were reclassified as eligible, while 2% (3 / 176), 6% (10 / 176), and 3% (2 / 60), respectively, were deemed ineligible. Inter-rater agreement on eligibility was moderate before (κ=0.46) and after (κ=0.43) adding epithelial maps but remained poor in borderline cases (κ=0.14 and 0.12, respectively). Agreement on epithelial profile features ranged from poor to fair (κ=−0.78 to 0.35). Corneal topography and BAD were ranked as most influential, followed by epithelial mapping. Conclusion: Epithelial mapping frequently shifted decisions toward eligibility. However, poor inter-expert agreement highlights the need for standardized, safety-oriented interpretation to ensure consistent ectasia risk assessment prior to refractive surgery.


  • Open Access

    Comparison of Refractive Outcomes After Phacoemulsification and Combined 25-Gauge Phacovitrectomy with Implantation of Plate-Haptic Toric Intraocular Lenses

    by Lara Buhl, Julian Langer, Franziska Kruse, Niklas Mohr, Thomas Kreutzer, Wolfgang Mayer, Stefan Kassumeh, Siegfried Priglinger

    Objectives: To compare intraocular lens (IOL) position and refractive outcomes between eyes that underwent sole phacoemulsification with those that underwent combined 25-gauge phacovitrectomy with a plate-haptic toric IOL implantation. Methods: This retrospective study included 60 eyes of 60 patients. Of these, 30 eyes underwent 25-gauge phacovitrectomy, while the other 30 eyes received phacoemulsification alone. In both groups, a plate-haptic toric intraocular lens (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted. The main outcome measures were the refractive outcome, the refraction prediction error (PE), the difference in the postoperative anatomical lens position (ALP) change, and rotational stability. Results: The mean spherical equivalent decreased considerably from −2 ± 4.4 diopters (D) to −0.6 ± 1.4 D after phacovitrectomy (p = 0.05) and −0.7 D ± 5.5 D to −0.1 ± 1.1 D after phacoemulsification (p = 0.5). The prediction error (PE) was comparable between the two groups for all formulas (Haigis-T: p = 0.8, Barrett TK Toric: p = 0.8, Z CALC: p = 0.7). No significant difference in absolute ALP change and postoperative rotational stability was observed between the phacovitrectomy and phacoemulsification group (1.4 mm vs. 1.4 mm, p = 0.96; 2.9° vs. 2.1°, p = 0.5). Conclusions: The implantation of plate-haptic toric IOLs in the combined phacovitrectomy group resulted in refraction and IOL positioning outcomes comparable to those in the phacoemulsification-only group.


  • Open Access

    Corneal Epithelial Wavefront Error as a Novel Diagnostic Marker for Epithelial Basement Membrane Dystrophy

    by Vitus Grauvogl, Wolfgang J. Mayer, Jakob Siedlecki, Niklas Mohr, Martin Dirisamer, Siegfried G. Priglinger, Stefan Kassumeh, Nikolaus Luft

    Synopsis: Corneal epithelial wavefront error and epithelial thickness variance qualify as highly sensitive and specific biomarkers for epithelial basement membrane dystrophy (EBMD). The biomarkers show a normalization after treatment of EBMD with phototherapeutic keratectomy. Purpose: To gauge the diagnostic value of epithelial basement membrane dystrophy (EBMD), a novel spectral-domain optical coherence tomography (SD-OCT)-based imaging modality for simultaneous morphological (thickness profile) and refractive (optical wavefront) assessment of the corneal epithelial layer in one of the most common but often underdiagnosed corneal dystrophies. Methods: In this prospective observational study, a total of 32 eyes of 32 patients diagnosed with EBMD and 32 eyes of 32 healthy control subjects were examined with high-resolution anterior segment SD-OCT (MS-39; CSO, Florence, Italy). Various epithelial thickness and epithelial wavefront-derived terms were compared between groups and receiver operating characteristic (ROC) curves were computed to analyze the diagnostic capacity of the respective parameters. A total of 17 of 32 EBMD patients underwent treatment with phototherapeutic keratectomy (PTK) and were followed up for 3 months. Results: Epithelial thickness variance (60.4 ± 56.7 µm versus 7.6 ± 6.1 µm) and interquartile range (11.0 ± 6.9 versus 3.3 ± 1.9 µm) were markedly elevated in EBMD patients as compared with healthy controls (both with p < 0.001). Epithelial wavefront analysis showed a highly statistically significant excess in all examined aberration terms in EBMD patients (all with p < 0.001). Significantly greater areas under the curve (AUCs) were yielded by the epithelial wavefront-derived parameters (e.g., total epithelial wavefront error: AUC = 0.966; 95% confidence interval (CI) 0.932–1) than by the epithelial thickness-derived parameters (e.g., variance: AUC = 0.919; 95% CI 0.848–0.990). Conclusions: Corneal epithelial wavefront aberrometry proved valuable as an objective biomarker for EBMD, with high sensitivity and specificity. PTK resulted in a reduction of morphological and refractive epithelial irregularities in EBMD.


  • Open Access

    Corneal Epithelial Wavefront Error as a Novel Objective Biomarker Diagnostic Marker for Epithelial Basement Membrane Dystrophy

    by Vitus Grauvogl, Wolfgang J. Mayer, Jakob Siedlecki, Niklas Mohr, Martin Dirisamer, Siegfried Georg Priglinger, Stefan Kassumeh, Nikolaus Luft

    Synopsis Corneal epithelial wavefront error and epithelial thickness variance qualify as highly sensitive and specific biomarkers for epithelial basement membrane dystrophy (EBMD). The biomarkers show a normalization after treatment of EBMD with phototherapeutic keratectomy. Purpose: To gauge the diagnostic value of a novel spectral-domain optical coherence tomography (SD-OCT) based imaging modality for simultaneous morphological (thickness profile) and refractive (optical wavefront) assessment of the corneal epithelial layer in one of the most common but often underdiagnosed corneal dystrophies: epithelial basement membrane dystrophy (EBMD). Methods: In this prospective observational study, a total of 32 eyes of 32 patients diagnosed with EBMD and 32 eyes of 32 healthy control subjects were examined with high-resolution anterior segment SD-OCT (MS-39; CSO, Florence, Italy). Various epithelial thickness and epithelial wavefront derived terms were compared between groups and receiver operating characteristic (ROC) curves were computed to analyze the diagnostic capacity of the respective parameters. A total of 17 of 32 EBMD patients underwent treatment with phototherapeutic keratectomy (PTK) and were followed up for 3 months. Results: Epithelial thickness variance (60.4 ± 56.7 µm versus 7.6 ± 6.1 µm) and interquartile range (11.0±6.9 versus 3.3±1.9 µm) were markedly elevated in EBMD patients as compared with healthy controls (both with p < 0.001). Epithelial wavefront analysis showed a highly statistically significant excess in all examined aberration terms in EBMD patients (all with p < 0.001). Significantly greater areas under the curve (AUC) were yielded by the epithelial wavefront derived parameters (e.g. total epithelial wavefront error: AUC = 0.966; 95% confidence interval (CI) 0.932 – 1) than by the epithelial thickness-derived parameters (e.g., variance: AUC = 0.919; 95% CI 0.848 – 0.990). Conclusion: Corneal epithelial wavefront aberrometry proved valuable as an objective biomarker for EBMD with high sensitivity and specificity. PTK resulted in a reduction of morphological and refractive epithelial irregularities in EBMD.


  • Open Access

    Enhancing ectasia screening using advanced AS-OCT: a case series of challenging refractive candidates

    by Niklas Mohr, Stefan Kassumeh, Nikolaus Luft, Martin Dirisamer, Siegfried G. Priglinger, Wolfgang J. Mayer

    Purpose: Ectasia screening in candidates for laser refractive surgery is mandatory during preoperative evaluation. Despite the availability of modern imaging techniques, refractive surgeons often face borderline decisions when patients present with suspicious tomographic findings. This case series presents refractive candidates with suspicious tomographic findings and demonstrates how to interpret them using Scheimpflug imaging and additional anterior segment optical coherence tomography (AS-OCT).Setting: Department of Ophthalmology, University Hospital, LMU Munich.Case series: This case series examines six potential candidates for refractive surgery with a mean age of 29.2 ± 3.9 years, whose corneal assessments using Scheimpflug imaging raised suspicion for ectasia. Each candidate was additionally examined with AS-OCT and reevaluated. The mean manifest subjective spherical equivalent was -3.67 ± 1.8 diopters. The total corneal thickness measured 537 µm ± 30 µm at its thinnest point. None of the candidates had any reported underlying corneal or ophthalmic diseases, and slit lamp examinations revealed no abnormal morphological findings.Conclusions: Both Scheimpflug imaging and AS-OCT are appropriate tools for screening refractive candidates for ectasia. While topographic and elevation analyses yielded comparable results regarding corneal structure, the epithelial mapping provided by AS-OCT played a critical role in decision-making for cases with borderline tomographic findings. Establishing a global consensus on the use of epithelial mapping in ectasia screening is necessary.


  • Optimizing Refractive Outcomes of SMILE: Artificial Intelligence versus Conventional State-of-the-Art Nomograms

    by Nikolaus Luft, Niklas Mohr, Elmar Spiegel, Hannah Marchi, Jakob Siedlecki, Lisa Harrant, Wolfgang J. Mayer, Martin Dirisamer, Siegfried G. Priglinger

    AI (artificial intelligence)-based methodologies have become established tools for researchers and physicians in the entire field of ophthalmology. However, the potential of AI to optimize the refractive outcome of keratorefractive surgery by means of machine learning (ML)-based nomograms has not been exhausted yet. In this study, we wanted to comprehensively compare state-of-the-art conventional nomograms for Small-Incision-Lenticule-Extraction (SMILE) with a novel ML-based nomogram regarding both their spherical and astigmatic predictability. A total of 1,342 eyes were analyzed for creation of three different nomograms based on a linear model (LM), a generalized additive mixed model (GAMM) and an artificial-neuronal-network (ANN), respectively. A total of 16 patient- and treatment-related features were included. Each model was trained by 895 eyes and validated by the remaining 447 eyes. Predictability was assessed by the difference between attempted and achieved change in spherical equivalent (SE) and the difference between target induced astigmatism (TIA) and surgically induced astigmatism (SIA). The root mean squared error (RMSE) of each model was computed as a measure of overall model performance. The RMSE of LM, GAMM and ANN were 0.355, 0.348 and 0.367 for the prediction of SE and 0.279, 0.278 and 0.290 for the astigmatic correction, respectively. By applying the created models, the theoretical yield of eyes within ±0.50 D of SE from target refraction improved from 82 to 83% (LM), 84% (GAMM) and 83% (ANN), respectively. Astigmatic outcomes showed an improvement of eyes within ±0.50 D from TIA from 90 to 93% (LM), 93% (GAMM) and 92% (ANN), respectively. Subjective manifest refraction was the single most influential covariate in all models. Machine learning endorsed the validity of state-of-the-art linear and non-linear SMILE nomograms. However, improving the accuracy of subjective manifest refraction seems warranted for optimizing ±0.50 D SE predictability beyond an apparent methodological 90% limit.


  • Pellucid marginal degeneration versus keratoconus: distinction with wide-field SD-OCT corneal sublayer pachymetry

    by Niklas Mohr, Mehdi Shajari, Daniel Krause, Stefan Kassumeh, Jakob Siedlecki, Siegfried G Priglinger, Wolfgang J Mayer, Nikolaus Luft

    Purpose To evaluate the capability of wide-field spectral-domain optical coherence tomography (SD-OCT) corneal sublayer pachymetry to distinguish between keratoconus and pellucid marginal degeneration (PMD). Methods This prospective cross-sectional study included 69 eyes (59 with keratoconus and 10 with PMD) of 69 patients. All patients were examined three subsequent times with the RTVue XR system. Pachymetry maps of the total cornea (CT), the epithelium (ET) and the stroma were generated using the onboard software. For analysis of reliability, the coefficients of variation and intraclass correlation coefficients (ICC) were calculated. Receiver operating characteristic analyses were performed to elaborate the most accurate pachymetric parameters for distinguishing between PMD and keratoconus. Results Overall repeatability of (sublayer) pachymetry was comparably good in both keratoconus (ICC ranging between 0.827 and 0.986) and PMD (ICC ranging between 0.753 and 0.998). Measurement reliability in keratoconic eyes was a negative function of Kmax (pConclusion Wide-field SD-OCT corneal sublayer pachymetry showed good reliability in PMD and keratoconus and may be useful to differentiate between the two ectatic diseases.