Diffusivity Measurement by Single-Molecule Recycling in a Capillary Microchannel
Open Access
- 6 July 2021
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 12 (7) , 800
Abstract
Microfluidic devices have been extensively investigated in recent years in fields including ligand-binding analysis, chromatographic separation, molecular dynamics, and DNA sequencing. To prolong the observation of a single molecule in aqueous buffer, the solution in a sub-micron scale channel is driven by a electric field and reversed after a fixed delay following each passage, so that the molecule passes back and forth through the laser focus and the time before irreversible photobleaching is extended. However, this practice requires complex chemical treatment to the inner surface of the channel to prevent unexpected sticking to the surface and the confined space renders features, such as a higher viscosity and lower dielectric constant, which slow the Brownian motion of the molecule compared to the bulk solution. Additionally, electron beam lithography used for the fabrication of the nanochannel substantially increases the cost, and the sub-micron dimensions make the molecule difficult to locate. In this paper, we propose a method of single-molecule recycling in a capillary microchannel. A commercial fused-silica capillary with an inner diameter of 2 microns is chopped into a 1-inch piece and is fixed onto a cover slip. Two o-rings on the sides used as reservoirs and an o-ring in the middle used as observation window are glued over the capillary. The inner surface of the capillary is chemically processed to reduce the non-specific sticking and to improve capillary effect. The device does not require high-precision fabrication and thus is less costly and easier to prepare than the nanochannel. 40 nm Fluospheres® in 50% methanol are used as working solution. The capillary is translated by a piezo stage to recycle the molecule, which diffuses freely through the capillary, and a confocal microscope is used for fluorescence collection. The passing times of the molecule through the laser focus are calculated by a real-time control system based on an FPGA, and the commands of translation are given to the piezo stage through a feedback algorithm. The larger dimensions of the capillary overcomes the strong sticking, the reduced diffusivity, and the difficulty of localizing the molecule. We have achieved a maximum number of recycles of more than 200 and developed a maximum-likelihood estimation of the diffusivity of the molecule, which attains results of the same magnitude as the previous report. This technique simplifies the overall procedure of the single-molecule recycling and could be useful for the ligand-binding studies in high-throughput screening.Keywords
Funding Information
- National Science Foundation (100408)
This publication has 28 references indexed in Scilit:
- Three-dimensional feedback-driven trapping of a single nanoparticle or molecule in aqueous solution with a confocal fluorescence microscopeOptics Express, 2019
- Nobel Lecture: Single-molecule spectroscopy, imaging, and photocontrol: Foundations for super-resolution microscopyReviews of Modern Physics, 2015
- Three-dimensional tracking of a single fluorescent nanoparticle using four-focus excitation in a confocal microscopeOptics Express, 2014
- Optical Trapping of a Single ProteinNano Letters, 2011
- Watching conformational- and photodynamics of single fluorescent proteins in solutionNature Chemistry, 2010
- Confocal, Three-Dimensional Tracking of Individual Quantum Dots in High-Background EnvironmentsAnalytical Chemistry, 2008
- Guiding a confocal microscope by single fluorescent nanoparticlesOptics Letters, 2007
- New directions in single-molecule imaging and analysisProceedings of the National Academy of Sciences, 2007
- THEORY OF SINGLE-MOLECULE SPECTROSCOPY: Beyond the Ensemble AverageAnnual Review of Physical Chemistry, 2004
- Methods of single-molecule fluorescence spectroscopy and microscopyReview of Scientific Instruments, 2003