Bo Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bo Wang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Zeren Li
Shenzhen Technology University
2 shared publications- Chun-Ke Zhang
Tuoren Medical Device Research Development Institute Co., Ltd, Henan Key Laboratory of Medical Polymer Materials Technology and Application, Tuoren Health Technology Industrial Park, Changyuan, Henan, China
1 shared publication - Guosheng Wang
Tuoren Medical Device Research Development Institute Co., Ltd, Henan Key Laboratory of Medical Polymer Materials Technology and Application, Tuoren Health Technology Industrial Park, Changyuan, Henan, China
1 shared publication - Huiling Li
Institute of Mechanics, State Key Laboratory of Nonlinear Mechanics, Chinese Academy of Sciences, Beijing, China
1 shared publication Jingqiang Cui
Tuoren Medical Device Research Development Institute Co., Ltd, Henan Key Laboratory of Medical Polymer Materials Technology and Application, Tuoren Health Technology Industrial Park, Changyuan, Henan, China
1 shared publicationJunwen Liao
1 shared publication
Latest Publications
- 30 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Dialysis Adequacy Sensor with Systematic Error Correction Algorithm for Hemodialysis Machines
During hemodialysis, real-time monitoring of patients’ dialysis adequacy on hemodialysis machines can prevent the complications and improve the long-term survival rate of patients. However, current online monitoring technologies are limited by various shortcomings, such as low accuracy of the conductivity method, poor repeatability of the electrochemical method, and systematic errors in the ultraviolet (UV) spectrophotometry. Among them, UV spectrophotometry is more suitable for realtime monitoring of dialysis adequacy on hemodialysis machines because of its advantages of non-contact and high sampling rate. Here, this paper proposes a dialysis adequacy sensor (DAS) based on UV spectrophotometry, and develops a correction algorithm by modeling the theoretical optical path to improve real-time monitoring accuracy. The error in urea concentration ratio is reduced by about ten times in the laboratory environment, which proves the effectiveness of the calibration algorithm. Clinical trials have demonstrated that the proposed sensor and implemented correction algorithm can precisely monitor dialysis adequacy during patient treatment, which can greatly reduce the error from 133.9% to 5.56%. The sensor reliably tracks the fluctuations in urea clearance rates, providing an effective indication of dialysis adequacy, which demonstrates strong potential for broad application among hemodialysis machines.
- 30 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Dialysis Adequacy Sensor with Systematic Error Correction Algorithm for Hemodialysis Machines
During hemodialysis, real-time monitoring of patients’ dialysis adequacy on hemodialysis machines can prevent the complications and improve the long-term survival rate of patients. However, current online monitoring technologies are limited by various shortcomings, such as low accuracy of the conductivity method, poor repeatability of the electrochemical method, and systematic errors in the ultraviolet (UV) spectrophotometry. Among them, UV spectrophotometry is more suitable for realtime monitoring of dialysis adequacy on hemodialysis machines because of its advantages of non-contact and high sampling rate. Here, this paper proposes a dialysis adequacy sensor (DAS) based on UV spectrophotometry, and develops a correction algorithm by modeling the theoretical optical path to improve real-time monitoring accuracy. The error in urea concentration ratio is reduced by about ten times in the laboratory environment, which proves the effectiveness of the calibration algorithm. Clinical trials have demonstrated that the proposed sensor and implemented correction algorithm can precisely monitor dialysis adequacy during patient treatment, which can greatly reduce the error from 133.9% to 5.56%. The sensor reliably tracks the fluctuations in urea clearance rates, providing an effective indication of dialysis adequacy, which demonstrates strong potential for broad application among hemodialysis machines.
- 29 August 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (17) , 4605-4608
Improved measurement of the glue layer in composite material by using sparse deconvolution
Due to its powerful penetration, and greater spatial resolution than microwaves and ultrasonic waves, the terahertz technique stands out as being particularly useful in identifying thin glue layers in multilayered materials. However, the arrival times of echoes are challenging to pinpoint from the experimental data because of the temporal form of the incident pulse and the system noise. Here, two terahertz signal sparse deconvolution algorithms are studied to more accurately identify the times of the echoes. Using the circulant structure of the convolution matrix, the method’s computation time can be lowered to hundreds of milliseconds. In addition, a method based on group velocity dispersion is investigated to reduce the impact of time-varying pulses with minimal computational expense. The presented algorithms have the potential to be employed in real-time inspection in production lines due to their quick speed and high confidence.
- 29 August 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (17) , 4605-4608
Improved measurement of the glue layer in composite material by using sparse deconvolution
Due to its powerful penetration, and greater spatial resolution than microwaves and ultrasonic waves, the terahertz technique stands out as being particularly useful in identifying thin glue layers in multilayered materials. However, the arrival times of echoes are challenging to pinpoint from the experimental data because of the temporal form of the incident pulse and the system noise. Here, two terahertz signal sparse deconvolution algorithms are studied to more accurately identify the times of the echoes. Using the circulant structure of the convolution matrix, the method’s computation time can be lowered to hundreds of milliseconds. In addition, a method based on group velocity dispersion is investigated to reduce the impact of time-varying pulses with minimal computational expense. The presented algorithms have the potential to be employed in real-time inspection in production lines due to their quick speed and high confidence.
- 11 April 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 388
Amino-acid classification based on terahertz absorption spectroscopy with Gaussian process and maximum likelihood
- 11 April 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 388
Amino-acid classification based on terahertz absorption spectroscopy with Gaussian process and maximum likelihood
- Open Access
- 20 June 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (12) , 2114
Classification of Amino Acids Using Hybrid Terahertz Spectrum and an Efficient Channel Attention Convolutional Neural Network
Terahertz (THz) spectroscopy is the de facto method to study the vibration modes and rotational energy levels of molecules and is a widely used molecular sensor for non-destructive inspection. Here, based on the THz spectra of 20 amino acids, a method that extracts high-dimensional features from a hybrid spectrum combined with absorption rate and refractive index is proposed. A convolutional neural network (CNN) calibrated by efficient channel attention (ECA) is designed to learn from the high-dimensional features and make classifications. The proposed method achieves an accuracy of and on two testing datasets, which are and higher than the method solely classifying the absorption spectrum. The proposed method also realizes a processing speed of 3782.46 frames per second (fps), which is the highest among all the methods in comparison. Due to the compact size, high accuracy, and high speed, the proposed method is viable for future applications in THz chemical sensors.- 20 June 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (12) , 2114
Open AccessClassification of Amino Acids Using Hybrid Terahertz Spectrum and an Efficient Channel Attention Convolutional Neural Network
Terahertz (THz) spectroscopy is the de facto method to study the vibration modes and rotational energy levels of molecules and is a widely used molecular sensor for non-destructive inspection. Here, based on the THz spectra of 20 amino acids, a method that extracts high-dimensional features from a hybrid spectrum combined with absorption rate and refractive index is proposed. A convolutional neural network (CNN) calibrated by efficient channel attention (ECA) is designed to learn from the high-dimensional features and make classifications. The proposed method achieves an accuracy of and on two testing datasets, which are and higher than the method solely classifying the absorption spectrum. The proposed method also realizes a processing speed of 3782.46 frames per second (fps), which is the highest among all the methods in comparison. Due to the compact size, high accuracy, and high speed, the proposed method is viable for future applications in THz chemical sensors. - 11 May 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (11) , 18238-18249
Learned iterative shrinkage and thresholding algorithm for terahertz sparse deconvolution
Terahertz sparse deconvolution based on an iterative shrinkage and thresholding algorithm (ISTA) has been used to characterize multilayered structures with resolution equivalent to or finer than the sampling period of the measurement. However, this method was only studied on thin samples to separate the overlapped echos that can’t be distinguished by other deconvolution algorithms. Besides, ISTA heavily depends on the convolution matrix consisting of delayed incident pulse, which is difficult to precisely extricate from the reference signal, and thereby fluctuations caused by noise are occasionally treated as echos. In this work, a terahertz sparse deconvolution based on a learned iterative shrinkage and thresholding algorithm (LISTA) is proposed. The method enclosed the matrix multiplication and soft thresholding in a block and cascaded multiple blocks together to form a deep network. The convolution matrices of the network were updated by stochastic gradient descent to minimize the distance between the output sparse vector and the optimal sparse representation of the signal, and subsequently the trained network made more precise estimation of the echos than ISTA. Additionally, LISTA is notably faster than ISTA, which is important for real-time tomographic-image processing. The algorithm was evaluated on terahertz tomographic imaging of a high-density poly ethylene (HDPE) sample, revealing obvious improvements in detecting defects of different sizes and depths. This technique has potential usage in nondestructive testings of thick samples, where echos reflected by minor defects are not discernible by existed deconvolution algorithms.
- 11 May 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (11) , 18238-18249
Learned iterative shrinkage and thresholding algorithm for terahertz sparse deconvolution
Terahertz sparse deconvolution based on an iterative shrinkage and thresholding algorithm (ISTA) has been used to characterize multilayered structures with resolution equivalent to or finer than the sampling period of the measurement. However, this method was only studied on thin samples to separate the overlapped echos that can’t be distinguished by other deconvolution algorithms. Besides, ISTA heavily depends on the convolution matrix consisting of delayed incident pulse, which is difficult to precisely extricate from the reference signal, and thereby fluctuations caused by noise are occasionally treated as echos. In this work, a terahertz sparse deconvolution based on a learned iterative shrinkage and thresholding algorithm (LISTA) is proposed. The method enclosed the matrix multiplication and soft thresholding in a block and cascaded multiple blocks together to form a deep network. The convolution matrices of the network were updated by stochastic gradient descent to minimize the distance between the output sparse vector and the optimal sparse representation of the signal, and subsequently the trained network made more precise estimation of the echos than ISTA. Additionally, LISTA is notably faster than ISTA, which is important for real-time tomographic-image processing. The algorithm was evaluated on terahertz tomographic imaging of a high-density poly ethylene (HDPE) sample, revealing obvious improvements in detecting defects of different sizes and depths. This technique has potential usage in nondestructive testings of thick samples, where echos reflected by minor defects are not discernible by existed deconvolution algorithms.
- 20 December 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 39 (3) , A18-A24
Qualitative detection of amino acids in a mixture with terahertz spectroscopic imaging
Terahertz time-domain spectroscopy (THz-TDS) is widely used in non-destructive testing and chemical identification due to the wide spectrum, low photon energy, distinctive absorption spectra, and higher intensity than other thermal radiators. Here, we propose a method to detect amino acids from a mixture at room temperature and in humid air. A THz-TDS spectrometer scans tablets of amino acid mixtures laid out on a polyethylene plate in transmission mode. The resulting spectroscopic imaging is then converted to probability maps (chemical maps), where the region containing the expected amino acid has higher pixel values, by a matrix manipulation with the matrix of absorption spectra. This approach is substantially resistant to air humidity and scattering caused by uneven grain sizes and is applicable to substances without strong absorption features. A classifier based on LeNet-5 is built to identify the subsection of the chemical map containing the expected substance, and the prediction reaches 100% accuracy for the testing dataset. The results of the classifier are compared with those of a support vector machine, whose accuracy is much lower due to its inferior ability to recognize complex patterns. The proposed method will enable us to qualitatively detect a component from an unknown mixture in a single measurement and will be useful for bio-molecule detection in real-life scenarios.
- 20 December 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 39 (3) , A18-A24
Qualitative detection of amino acids in a mixture with terahertz spectroscopic imaging
Terahertz time-domain spectroscopy (THz-TDS) is widely used in non-destructive testing and chemical identification due to the wide spectrum, low photon energy, distinctive absorption spectra, and higher intensity than other thermal radiators. Here, we propose a method to detect amino acids from a mixture at room temperature and in humid air. A THz-TDS spectrometer scans tablets of amino acid mixtures laid out on a polyethylene plate in transmission mode. The resulting spectroscopic imaging is then converted to probability maps (chemical maps), where the region containing the expected amino acid has higher pixel values, by a matrix manipulation with the matrix of absorption spectra. This approach is substantially resistant to air humidity and scattering caused by uneven grain sizes and is applicable to substances without strong absorption features. A classifier based on LeNet-5 is built to identify the subsection of the chemical map containing the expected substance, and the prediction reaches 100% accuracy for the testing dataset. The results of the classifier are compared with those of a support vector machine, whose accuracy is much lower due to its inferior ability to recognize complex patterns. The proposed method will enable us to qualitatively detect a component from an unknown mixture in a single measurement and will be useful for bio-molecule detection in real-life scenarios.
- Open Access
- 6 July 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (7) , 800
Diffusivity Measurement by Single-Molecule Recycling in a Capillary Microchannel
Microfluidic devices have been extensively investigated in recent years in fields including ligand-binding analysis, chromatographic separation, molecular dynamics, and DNA sequencing. To prolong the observation of a single molecule in aqueous buffer, the solution in a sub-micron scale channel is driven by a electric field and reversed after a fixed delay following each passage, so that the molecule passes back and forth through the laser focus and the time before irreversible photobleaching is extended. However, this practice requires complex chemical treatment to the inner surface of the channel to prevent unexpected sticking to the surface and the confined space renders features, such as a higher viscosity and lower dielectric constant, which slow the Brownian motion of the molecule compared to the bulk solution. Additionally, electron beam lithography used for the fabrication of the nanochannel substantially increases the cost, and the sub-micron dimensions make the molecule difficult to locate. In this paper, we propose a method of single-molecule recycling in a capillary microchannel. A commercial fused-silica capillary with an inner diameter of 2 microns is chopped into a 1-inch piece and is fixed onto a cover slip. Two o-rings on the sides used as reservoirs and an o-ring in the middle used as observation window are glued over the capillary. The inner surface of the capillary is chemically processed to reduce the non-specific sticking and to improve capillary effect. The device does not require high-precision fabrication and thus is less costly and easier to prepare than the nanochannel. 40 nm Fluospheres® in 50% methanol are used as working solution. The capillary is translated by a piezo stage to recycle the molecule, which diffuses freely through the capillary, and a confocal microscope is used for fluorescence collection. The passing times of the molecule through the laser focus are calculated by a real-time control system based on an FPGA, and the commands of translation are given to the piezo stage through a feedback algorithm. The larger dimensions of the capillary overcomes the strong sticking, the reduced diffusivity, and the difficulty of localizing the molecule. We have achieved a maximum number of recycles of more than 200 and developed a maximum-likelihood estimation of the diffusivity of the molecule, which attains results of the same magnitude as the previous report. This technique simplifies the overall procedure of the single-molecule recycling and could be useful for the ligand-binding studies in high-throughput screening.
- 6 July 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (7) , 800
Open AccessDiffusivity Measurement by Single-Molecule Recycling in a Capillary Microchannel
Microfluidic devices have been extensively investigated in recent years in fields including ligand-binding analysis, chromatographic separation, molecular dynamics, and DNA sequencing. To prolong the observation of a single molecule in aqueous buffer, the solution in a sub-micron scale channel is driven by a electric field and reversed after a fixed delay following each passage, so that the molecule passes back and forth through the laser focus and the time before irreversible photobleaching is extended. However, this practice requires complex chemical treatment to the inner surface of the channel to prevent unexpected sticking to the surface and the confined space renders features, such as a higher viscosity and lower dielectric constant, which slow the Brownian motion of the molecule compared to the bulk solution. Additionally, electron beam lithography used for the fabrication of the nanochannel substantially increases the cost, and the sub-micron dimensions make the molecule difficult to locate. In this paper, we propose a method of single-molecule recycling in a capillary microchannel. A commercial fused-silica capillary with an inner diameter of 2 microns is chopped into a 1-inch piece and is fixed onto a cover slip. Two o-rings on the sides used as reservoirs and an o-ring in the middle used as observation window are glued over the capillary. The inner surface of the capillary is chemically processed to reduce the non-specific sticking and to improve capillary effect. The device does not require high-precision fabrication and thus is less costly and easier to prepare than the nanochannel. 40 nm Fluospheres® in 50% methanol are used as working solution. The capillary is translated by a piezo stage to recycle the molecule, which diffuses freely through the capillary, and a confocal microscope is used for fluorescence collection. The passing times of the molecule through the laser focus are calculated by a real-time control system based on an FPGA, and the commands of translation are given to the piezo stage through a feedback algorithm. The larger dimensions of the capillary overcomes the strong sticking, the reduced diffusivity, and the difficulty of localizing the molecule. We have achieved a maximum number of recycles of more than 200 and developed a maximum-likelihood estimation of the diffusivity of the molecule, which attains results of the same magnitude as the previous report. This technique simplifies the overall procedure of the single-molecule recycling and could be useful for the ligand-binding studies in high-throughput screening.
- 15 January 2021
- Published by Optica Publishing Group in OSA Continuum
- Vol. 4 (1) , 212-228
Monte Carlo simulation and maximum-likelihood analysis of single-molecule recycling in a nanochannel
Prolonged observation of a single molecule in solution using a confocal microscope is possible by flowing solution through a nanochannel and reversing the flow a fixed delay after each passage so that the molecule passes back and forth through the laser focus. In this paper, Monte Carlo simulations are used to provide insight on capabilities and limitations of the single-molecule recycling procedure. Various computational methods for using photon detection times to estimate the times of passage of the molecule through the laser focus, based on matched digital filters and maximum-likelihood (ML) analysis, are compared using simulations. A new ML-based methodology is developed for estimating the single molecule diffusivity, and the uncertainty in the estimate, from the variation in the intervals between times of passage. Simulations show that with recycling ∼200 times, it should be possible to resolve molecules with diffusivities that differ by a factor of ∼1.3, which is smaller than that resolvable in ligand-binding measurements by fluorescence correlation spectroscopy. Also, it is found that the mean number of times a molecule is recycled can be extended by adjusting the delay between flow reversals to accommodate the diffusional motion of statistical outliers.
- 15 January 2021
- Published by Optica Publishing Group in OSA Continuum
- Vol. 4 (1) , 212-228
Monte Carlo simulation and maximum-likelihood analysis of single-molecule recycling in a nanochannel
Prolonged observation of a single molecule in solution using a confocal microscope is possible by flowing solution through a nanochannel and reversing the flow a fixed delay after each passage so that the molecule passes back and forth through the laser focus. In this paper, Monte Carlo simulations are used to provide insight on capabilities and limitations of the single-molecule recycling procedure. Various computational methods for using photon detection times to estimate the times of passage of the molecule through the laser focus, based on matched digital filters and maximum-likelihood (ML) analysis, are compared using simulations. A new ML-based methodology is developed for estimating the single molecule diffusivity, and the uncertainty in the estimate, from the variation in the intervals between times of passage. Simulations show that with recycling ∼200 times, it should be possible to resolve molecules with diffusivities that differ by a factor of ∼1.3, which is smaller than that resolvable in ligand-binding measurements by fluorescence correlation spectroscopy. Also, it is found that the mean number of times a molecule is recycled can be extended by adjusting the delay between flow reversals to accommodate the diffusional motion of statistical outliers.
- Open Access
- 1 January 2016
- Published by EJournal Publishing in International Journal of Information and Electronics Engineering
- Vol. 6 (2) , 123-129
Implementation and Testing of Autonomous Quad-Rotor Aerial Vehicle by Using Ardu-Pilot
- 1 January 2016
- Published by EJournal Publishing in International Journal of Information and Electronics Engineering
- Vol. 6 (2) , 123-129
Open AccessImplementation and Testing of Autonomous Quad-Rotor Aerial Vehicle by Using Ardu-Pilot