Toward teleoperated needle steering under continuous MRI guidance for prostate percutaneous interventions
- 12 August 2015
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 12 (3) , 355-369
Abstract
Background: To propose a human‐operated in‐room master–slave bevel‐tip needle steering system under continuous MRI guidance for prostate biopsy, in which the patient is kept in the scanner at all times and the process of needle placement is under continuous control of the physician.Methods: A 2‐DOF MRI‐compatible needle steering module is developed and integrated with an existing 4‐DOF transperineal robot, creating a 6‐DOF robotic platform for prostate interventions. An MRI‐compatible 2‐DOF master robot is also developed to enable remote needle steering. An MRI‐compatible 2‐DOF force/torque sensor was used on the master side. Bevel‐tip needle steering is implemented in order to compensate for the targeting error due to needle–tissue interaction.Results: MRI‐compatibility results demonstrated maximum 20% loss in signal to noise ratio (SNR). Robot functionality was not influenced by the magnetic field. Targeting error was reduced from 4.2 mm to 0.9 mm as a result of bevel‐tip needle steering.Conclusions: The feasibility of teleoperated bevel‐tip needle steering using the proposed system was shown in a phantom experiment. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
Funding Information
- NIH (R01CA111288)
This publication has 36 references indexed in Scilit:
- Accuracy study of a robotic system for MRI‐guided prostate needle placementThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Robotic system for MRI-guided prostate biopsy: feasibility of teleoperated needle insertion and ex vivo phantom studyInternational Journal of Computer Assisted Radiology and Surgery, 2011
- Does needle rotation improve lesion targeting?The International Journal of Medical Robotics and Computer Assisted Surgery, 2011
- Real-time cardiovascular magnetic resonance at high temporal resolution: radial FLASH with nonlinear inverse reconstructionJournal of Cardiovascular Magnetic Resonance, 2010
- Towards a teleoperated needle driver robot with haptic feedback for RFA of breast tumors under continuous MRIMedical Image Analysis, 2009
- A Force Feedback Teleoperated Needle Insertion Device for Percutaneous ProceduresThe International Journal of Robotics Research, 2009
- Advancements in Magnetic Resonance-Guided Robotic Interventions in the ProstateTopics in Magnetic Resonance Imaging, 2008
- Motion Planning Under Uncertainty for Image-guided Medical Needle SteeringThe International Journal of Robotics Research, 2008
- MR‐guided prostate interventionsJournal of Magnetic Resonance Imaging, 2008
- A Steady-Hand Robotic System for Microsurgical AugmentationThe International Journal of Robotics Research, 1999