Parametric Design of an Advanced Multi-Axial Energy-Storing-and-Releasing Ankle–Foot Prosthesis
Open Access
- 24 June 2024
- journal article
- research article
- Published by MDPI AG in Prosthesis
- Vol. 6 (4) , 726-743
Abstract
The ankle joint is pivotal in prosthetic feet, especially in Energy-Storing-and-Releasing feet, favoured by individuals with moderate to high mobility (K3/K4) due to their energy efficiency and simple construction. ESR feet, mainly designed for sagittal-plane motion, often exhibit high stiffness in other planes, leading to difficulties in adapting to varied ground conditions, potentially causing discomfort or pain. This study aims to present a systematic methodology for modifying the ankle joint’s stiffness properties across its three motion planes, tailored to individual user preferences, and to decouple the sagittal-plane behaviour from the frontal and transverse ones. To integrate the multi-axial ankle inside the MyFlex-η, the designing of experiments using finite element analysis was conducted to explore the impact of geometric parameters on the joint’s properties with respect to design constraints and to reach the defined stiffness targets on the three ankle’s motion planes. A prototype of the multi-axial ankle joint was then manufactured and tested under FEA-derived load conditions to validate the final configuration chosen. Composite elastic elements and complementary parts of the MyFlex-η, incorporating the multi-axial ankle joint, were developed, and the prosthesis was biomechanically tested according to lower limb prosthesis ISO standards and guidelines from literature and the American Orthotic and Prosthetic Association (AOPA). Experimental tests showed strong alignment with numerical predictions. Moreover, implementing the multi-axial ankle significantly increased frontal-plane compliance by 414% with respect to the same prosthesis with only one degree of freedom on the sagittal plane without affecting the main plane of locomotion performance.Keywords
Funding Information
- European Commission (780871)
This publication has 29 references indexed in Scilit:
- Benefits of an increased prosthetic ankle range of motion for individuals with a trans-tibial amputation walking with a new prosthetic footGait & Posture, 2018
- Biomechanics of the ankleOrthopaedics and Trauma, 2016
- Three-dimensional joint reaction forces and moments at the low back during over-ground walking in persons with unilateral lower-extremity amputationClinical Biomechanics, 2014
- Conceptual Design of a Powered Ankle-foot Prosthesis for Walking with Inversion and EversionProcedia Technology, 2014
- Kinematic adaptations of the hindfoot, forefoot, and hallux during cross-slope walkingGait & Posture, 2010
- Evaluation of force plate-less estimation of the trajectory of the centre of pressure during gait. Comparison of two anthropometric modelsGait & Posture, 2010
- Video task analysis of turning during activities of daily livingGait & Posture, 2007
- Regional differences in pain threshold and tolerance of the transtibial residual limb: Including the effects of age and interface materialArchives of Physical Medicine and Rehabilitation, 2005
- Stability criterion for controlling standing in able-bodied subjectsJournal of Biomechanics, 2000
- Calculation of area of stabilometric signals using principal component analysisPhysiological Measurement, 1996