Marco Leopaldi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marco Leopaldi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Zucchelli
Department of Industrial Engineering, University of Bologna, Bologna, Italy
7 shared publications - Johnnidel Tabucol
Department of Industrial Engineering, University of Bologna, Bologna, Italy
7 shared publications - Tommaso Maria Brugo
Department of Industrial Engineering, University of Bologna, Bologna, Italy
7 shared publications - Raffaella Carloni
Bernoulli Institute for Mathematics, Computer Science and Artificial Intelligence, Faculty of Science and Engineering, University of Groningen, Groningen, The Netherlands
4 shared publications - Magnus Oddsson
Research and Development, Össur, 110 Reykjavík, Iceland
2 shared publications Magnús Oddsson
Ssur, Reykjavik, Iceland
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 157207-157224
Autonomous Design of ESR Prosthetic Foot Via Evolutionary Algorithm to Reproduce Sagittal-Plane Elastic Response
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 157207-157224
Open AccessAutonomous Design of ESR Prosthetic Foot Via Evolutionary Algorithm to Reproduce Sagittal-Plane Elastic Response
- Open Access
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 106834-106848
Convolutional Neural Network Controller for Autonomous Variable Stiffness ESR Foot Prosthesis: The MyFlex-θ
Human ankles naturally adjust stiffness to accommodate various activities and terrains—an ability that conventional passive energy-storing-and-returning (ESR) prostheses cannot replicate due to their fixed stiffness. To address this limitation, this study introduces the MyFlex-θ prosthesis, an autonomous ESR foot equipped with a Variable Stiffness System (VSS) and a Human Activity Recognition (HAR) control system based on a Convolutional Neural Network (CNN) algorithm. The HAR-CNN system classifies seven activities—walking, fast walking, standing, ramp ascent/descent, and stair ascent/descent—using linear acceleration data from two embedded Inertial Measurement Units (IMUs). When three consecutive predictions are identical, the VSS actuator adjusts foot stiffness in real time. Offline evaluation of the HAR-CNN, following the optimization of nine input channels, algorithm hyperparameters, and sliding window and hop size configurations, achieved a classification accuracy of 97.2% (loss: 0.103). Real-time testing with an able-bodied participant yielded an accuracy of 91.5%, confirming robust performance under dynamic conditions. Furthermore, real-time ankle torque estimation was implemented using a third-order response surface derived from sixth-order polynomial Finite Element Analysis (FEA) models, correlating stiffness settings with IMU-recorded joint rotations. This integration of adaptive stiffness control and embedded torque estimation enables continuous, portable gait analysis. The MyFlex-θ represents a significant advancement toward intelligent prosthetic devices capable of autonomously adapting to user activity and biomechanical demands.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 106834-106848
Open AccessConvolutional Neural Network Controller for Autonomous Variable Stiffness ESR Foot Prosthesis: The MyFlex-θ
Human ankles naturally adjust stiffness to accommodate various activities and terrains—an ability that conventional passive energy-storing-and-returning (ESR) prostheses cannot replicate due to their fixed stiffness. To address this limitation, this study introduces the MyFlex-θ prosthesis, an autonomous ESR foot equipped with a Variable Stiffness System (VSS) and a Human Activity Recognition (HAR) control system based on a Convolutional Neural Network (CNN) algorithm. The HAR-CNN system classifies seven activities—walking, fast walking, standing, ramp ascent/descent, and stair ascent/descent—using linear acceleration data from two embedded Inertial Measurement Units (IMUs). When three consecutive predictions are identical, the VSS actuator adjusts foot stiffness in real time. Offline evaluation of the HAR-CNN, following the optimization of nine input channels, algorithm hyperparameters, and sliding window and hop size configurations, achieved a classification accuracy of 97.2% (loss: 0.103). Real-time testing with an able-bodied participant yielded an accuracy of 91.5%, confirming robust performance under dynamic conditions. Furthermore, real-time ankle torque estimation was implemented using a third-order response surface derived from sixth-order polynomial Finite Element Analysis (FEA) models, correlating stiffness settings with IMU-recorded joint rotations. This integration of adaptive stiffness control and embedded torque estimation enables continuous, portable gait analysis. The MyFlex-θ represents a significant advancement toward intelligent prosthetic devices capable of autonomously adapting to user activity and biomechanical demands.
- Open Access
- 24 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 653-663
The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex-ζ, an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex-ζ adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant’s results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex-ζ offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex-ζ could mark significant progress in prosthesis technology.
- 24 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 653-663
Open AccessThe MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex-ζ, an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex-ζ adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant’s results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex-ζ offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex-ζ could mark significant progress in prosthesis technology.
- Open Access
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33, 2823-2833
Human-in-the-Loop Optimization of the Stiffness and Alignment of a Prosthetic Foot to Reduce the Metabolic Cost of Walking
Improper tuning of prosthetic foot properties to the individual user limits the efficacy of current state-of-the-art prosthetic feet in terms of walking economy. This study aims to explore the potential of human-in-the-loop optimization to individually optimize prosthetic foot stiffness and alignment to decrease the metabolic cost of walking of transtibial amputees. 10 transtibial amputees underwent an optimization protocol while walking on a treadmill with an experimental prosthetic foot with tuneable stiffness and alignment. We aimed to minimize the metabolic cost of walking by optimizing the stiffness and alignment of the prosthetic foot, using an evolutionary optimization algorithm. The metabolic cost of walking during the post-test using optimal settings was compared with the pre-test using standard settings, and the post-test using standard settings. Human-in-the-loop optimization of the tuneable prosthetic foot resulted in optimal stiffness (4.41 ± 0.17 Nm/°) and alignment (2.40 ± 0.97°) settings that differ between participants. Walking on the prosthetic foot with optimized settings during the post-test resulted in a significant reduction in metabolic cost compared to the pre-test with standard settings (-10.6%). The metabolic cost during the post-test with standard settings was in between the pre-test with standard settings (-6.6%) and the post-test with optimal settings (-4.3%), indicating that part of the decrease in cost could be explained by motor adaptation of the user. Human-in-the-loop optimization can individually tune the stiffness and alignment of a prosthetic foot to lower the metabolic cost of walking for transtibial amputees and provides different optimal settings for each individual participant. Both optimization of prosthetic components and motor adaptation of the user contributed to the reduction in metabolic cost, which corroborates that human-in-the-loop optimization could enhance the efficacy of prosthetic devices.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33, 2823-2833
Open AccessHuman-in-the-Loop Optimization of the Stiffness and Alignment of a Prosthetic Foot to Reduce the Metabolic Cost of Walking
Improper tuning of prosthetic foot properties to the individual user limits the efficacy of current state-of-the-art prosthetic feet in terms of walking economy. This study aims to explore the potential of human-in-the-loop optimization to individually optimize prosthetic foot stiffness and alignment to decrease the metabolic cost of walking of transtibial amputees. 10 transtibial amputees underwent an optimization protocol while walking on a treadmill with an experimental prosthetic foot with tuneable stiffness and alignment. We aimed to minimize the metabolic cost of walking by optimizing the stiffness and alignment of the prosthetic foot, using an evolutionary optimization algorithm. The metabolic cost of walking during the post-test using optimal settings was compared with the pre-test using standard settings, and the post-test using standard settings. Human-in-the-loop optimization of the tuneable prosthetic foot resulted in optimal stiffness (4.41 ± 0.17 Nm/°) and alignment (2.40 ± 0.97°) settings that differ between participants. Walking on the prosthetic foot with optimized settings during the post-test resulted in a significant reduction in metabolic cost compared to the pre-test with standard settings (-10.6%). The metabolic cost during the post-test with standard settings was in between the pre-test with standard settings (-6.6%) and the post-test with optimal settings (-4.3%), indicating that part of the decrease in cost could be explained by motor adaptation of the user. Human-in-the-loop optimization can individually tune the stiffness and alignment of a prosthetic foot to lower the metabolic cost of walking for transtibial amputees and provides different optimal settings for each individual participant. Both optimization of prosthetic components and motor adaptation of the user contributed to the reduction in metabolic cost, which corroborates that human-in-the-loop optimization could enhance the efficacy of prosthetic devices.
- Open Access
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 97544-97556
Design and Mechanical Characterization of a Variable Stiffness ESR Foot Prosthesis
In this article, MyFlex-$\epsilon $ , an ESR foot prosthesis equipped with a light and manually adjustable mechanism that allows for varying its stiffness in the sagittal plane, and a systematic approach to calculate its rotation-stiffness curves are presented. Through a design of experiment conducted numerically using a two-dimensional (2D) finite element (FE) model, calibrated experimentally, a geometric parameter whose variation alters the sagittal plane stiffness of a prosthesis originally designed with invariable stiffness, MyFlex-$\delta $ , was determined. After building the mechanism and integrating it into MyFlex-$\delta $ to obtain MyFlex-$\epsilon $ , the displacement-force curves of the latter through tests equivalent to the static tests specified in ISO 10328 were determined. Based on the experimental results, the 2D FE model of MyFlex-$\epsilon $ was built and calibrated to determine its rotation-stiffness curves in the sagittal plane. Comparing the rotation-stiffness curves obtained with the most compliant setting to the stiffest setting, stiffness variations of 119%, 122%, 138%, and 162% at plantarflexion angles of −5° and −2.5°, and dorsiflexion angles of 7.5° and 15°, respectively, were found.- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 97544-97556
Open AccessDesign and Mechanical Characterization of a Variable Stiffness ESR Foot Prosthesis
In this article, MyFlex-$\epsilon $ , an ESR foot prosthesis equipped with a light and manually adjustable mechanism that allows for varying its stiffness in the sagittal plane, and a systematic approach to calculate its rotation-stiffness curves are presented. Through a design of experiment conducted numerically using a two-dimensional (2D) finite element (FE) model, calibrated experimentally, a geometric parameter whose variation alters the sagittal plane stiffness of a prosthesis originally designed with invariable stiffness, MyFlex-$\delta $ , was determined. After building the mechanism and integrating it into MyFlex-$\delta $ to obtain MyFlex-$\epsilon $ , the displacement-force curves of the latter through tests equivalent to the static tests specified in ISO 10328 were determined. Based on the experimental results, the 2D FE model of MyFlex-$\epsilon $ was built and calibrated to determine its rotation-stiffness curves in the sagittal plane. Comparing the rotation-stiffness curves obtained with the most compliant setting to the stiffest setting, stiffness variations of 119%, 122%, 138%, and 162% at plantarflexion angles of −5° and −2.5°, and dorsiflexion angles of 7.5° and 15°, respectively, were found. - Open Access
- 24 June 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (4) , 726-743
Parametric Design of an Advanced Multi-Axial Energy-Storing-and-Releasing Ankle–Foot Prosthesis
The ankle joint is pivotal in prosthetic feet, especially in Energy-Storing-and-Releasing feet, favoured by individuals with moderate to high mobility (K3/K4) due to their energy efficiency and simple construction. ESR feet, mainly designed for sagittal-plane motion, often exhibit high stiffness in other planes, leading to difficulties in adapting to varied ground conditions, potentially causing discomfort or pain. This study aims to present a systematic methodology for modifying the ankle joint’s stiffness properties across its three motion planes, tailored to individual user preferences, and to decouple the sagittal-plane behaviour from the frontal and transverse ones. To integrate the multi-axial ankle inside the MyFlex-η, the designing of experiments using finite element analysis was conducted to explore the impact of geometric parameters on the joint’s properties with respect to design constraints and to reach the defined stiffness targets on the three ankle’s motion planes. A prototype of the multi-axial ankle joint was then manufactured and tested under FEA-derived load conditions to validate the final configuration chosen. Composite elastic elements and complementary parts of the MyFlex-η, incorporating the multi-axial ankle joint, were developed, and the prosthesis was biomechanically tested according to lower limb prosthesis ISO standards and guidelines from literature and the American Orthotic and Prosthetic Association (AOPA). Experimental tests showed strong alignment with numerical predictions. Moreover, implementing the multi-axial ankle significantly increased frontal-plane compliance by 414% with respect to the same prosthesis with only one degree of freedom on the sagittal plane without affecting the main plane of locomotion performance.
- 24 June 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (4) , 726-743
Open AccessParametric Design of an Advanced Multi-Axial Energy-Storing-and-Releasing Ankle–Foot Prosthesis
The ankle joint is pivotal in prosthetic feet, especially in Energy-Storing-and-Releasing feet, favoured by individuals with moderate to high mobility (K3/K4) due to their energy efficiency and simple construction. ESR feet, mainly designed for sagittal-plane motion, often exhibit high stiffness in other planes, leading to difficulties in adapting to varied ground conditions, potentially causing discomfort or pain. This study aims to present a systematic methodology for modifying the ankle joint’s stiffness properties across its three motion planes, tailored to individual user preferences, and to decouple the sagittal-plane behaviour from the frontal and transverse ones. To integrate the multi-axial ankle inside the MyFlex-η, the designing of experiments using finite element analysis was conducted to explore the impact of geometric parameters on the joint’s properties with respect to design constraints and to reach the defined stiffness targets on the three ankle’s motion planes. A prototype of the multi-axial ankle joint was then manufactured and tested under FEA-derived load conditions to validate the final configuration chosen. Composite elastic elements and complementary parts of the MyFlex-η, incorporating the multi-axial ankle joint, were developed, and the prosthesis was biomechanically tested according to lower limb prosthesis ISO standards and guidelines from literature and the American Orthotic and Prosthetic Association (AOPA). Experimental tests showed strong alignment with numerical predictions. Moreover, implementing the multi-axial ankle significantly increased frontal-plane compliance by 414% with respect to the same prosthesis with only one degree of freedom on the sagittal plane without affecting the main plane of locomotion performance.
- Open Access
- 30 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4575
The Functionality Verification through Pilot Human Subject Testing of MyFlex-δ: An ESR Foot Prosthesis with Spherical Ankle Joint
Most biomechanical research has focused on level-ground walking giving less attention to other conditions. As a result, most lower limb prosthesis studies have focused on sagittal plane movements. In this paper, an ESR foot is presented, of which five different stiffnesses were optimized for as many weight categories of users. It is characterized by a spherical ankle joint, with which, combined with the elastic elements, the authors wanted to create a prosthesis that gives the desired stiffness in the sagittal plane but at the same time, gives flexibility in the other planes to allow the adaptation of the foot prosthesis to the ground conditions. The ESR foot was preliminarily tested by participants with transfemoral amputation. After a brief familiarization with the device, each participant was asked to wear markers and to walk on a sensorized treadmill to measure their kinematics and kinetics. Then, each participant was asked to leave feedback via an evaluation questionnaire. The measurements and feedback allowed us to evaluate the performance of the prosthesis quantitatively and qualitatively. Although there were no significant improvements on the symmetry of the gait, due also to very limited familiarization time, the participants perceived an improvement brought by the spherical ankle joint.
- 30 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4575
Open AccessThe Functionality Verification through Pilot Human Subject Testing of MyFlex-δ: An ESR Foot Prosthesis with Spherical Ankle Joint
Most biomechanical research has focused on level-ground walking giving less attention to other conditions. As a result, most lower limb prosthesis studies have focused on sagittal plane movements. In this paper, an ESR foot is presented, of which five different stiffnesses were optimized for as many weight categories of users. It is characterized by a spherical ankle joint, with which, combined with the elastic elements, the authors wanted to create a prosthesis that gives the desired stiffness in the sagittal plane but at the same time, gives flexibility in the other planes to allow the adaptation of the foot prosthesis to the ground conditions. The ESR foot was preliminarily tested by participants with transfemoral amputation. After a brief familiarization with the device, each participant was asked to wear markers and to walk on a sensorized treadmill to measure their kinematics and kinetics. Then, each participant was asked to leave feedback via an evaluation questionnaire. The measurements and feedback allowed us to evaluate the performance of the prosthesis quantitatively and qualitatively. Although there were no significant improvements on the symmetry of the gait, due also to very limited familiarization time, the participants perceived an improvement brought by the spherical ankle joint.
- Open Access
- 23 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 97
Structural FEA-Based Design and Functionality Verification Methodology of Energy-Storing-and-Releasing Prosthetic Feet
The prosthetic feet that are most often prescribed to individuals with K3/K4 levels of ambulation are the ESR feet. ESR stands for energy-storing and -releasing. The elastic energy is stored by the elastic elements in composite materials (carbon fiber or glass fiber). ESR feet must be developed and optimized in terms of stiffness, taking into account the loads that a healthy human foot undergoes and its kinematics while walking. So far, state-of-the-art analyses show that the literature approaches for prosthetic foot design are not based on a systematic methodology. With the aim of optimizing the stiffness of ESR feet following a methodological procedure, a methodology based on finite element structural analysis, standard static testing (ISO 10328) and functional verification was optimized and it is presented in this paper. During the path of optimization of the foot prototypes, this methodology was validated experimentally. It includes the following: (i) geometry optimization through two-dimensional finite element analysis; (ii) material properties optimization through three-dimensional finite element analysis; (iii) validation test on physical prototypes; (iv) functionality verification through dynamic finite element analysis. The design and functional verification of MyFlex-, a three-blade ESR foot prosthesis, is presented to describe the methodology and demonstrate its usability.- 23 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 97
Open AccessStructural FEA-Based Design and Functionality Verification Methodology of Energy-Storing-and-Releasing Prosthetic Feet
The prosthetic feet that are most often prescribed to individuals with K3/K4 levels of ambulation are the ESR feet. ESR stands for energy-storing and -releasing. The elastic energy is stored by the elastic elements in composite materials (carbon fiber or glass fiber). ESR feet must be developed and optimized in terms of stiffness, taking into account the loads that a healthy human foot undergoes and its kinematics while walking. So far, state-of-the-art analyses show that the literature approaches for prosthetic foot design are not based on a systematic methodology. With the aim of optimizing the stiffness of ESR feet following a methodological procedure, a methodology based on finite element structural analysis, standard static testing (ISO 10328) and functional verification was optimized and it is presented in this paper. During the path of optimization of the foot prototypes, this methodology was validated experimentally. It includes the following: (i) geometry optimization through two-dimensional finite element analysis; (ii) material properties optimization through three-dimensional finite element analysis; (iii) validation test on physical prototypes; (iv) functionality verification through dynamic finite element analysis. The design and functional verification of MyFlex-, a three-blade ESR foot prosthesis, is presented to describe the methodology and demonstrate its usability.