The design and application of magnetic landmark used for magnetic fiducialization of HEPS insertion devices*
- 3 July 2024
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105002
Abstract
Achieving high performance in synchrotron radiation light sources demands increased precision in fiducialization and alignment of insertion devices (IDs). Conventional sensor systems utilizing Hall probes for high-precision magnetic field measurements face limitations in determining the absolute position of the magnetic center of IDs. In this paper, the Magnetic Landmark (MLK), a novel solution based on a magnetized block structure, is designed to address this challenge. The MLK serves as an intermediary, establishing contact between the magnetic center of IDs and their externally accessible fiducials, thus enabling high-precision alignment. Through analysis of magnetic field distribution, self-calibration precision, and practical application of the MLK, the following conclusions are drawn: when the Hall probe is positioned within 0.5 mm of the magnetic field zero point inside the MLK, the measurement accuracy of the zero point for normal and skew quadrupole magnetic fields reaches 7 and 2 μm, respectively. Additionally, the self-measurement accuracy of the MLK is 10 and 4 μm in the transverse and vertical directions, respectively. These accuracies meet our usage requirements. The MLK demonstrates efficacy in aligning the magnetic center of High Energy Photon Source (HEPS) In-air undulators, achieving alignment accuracies of 16 μm in the transverse direction and 11 μm in the vertical direction, surpassing the 30 μm accuracy stipulated in the physical design. Furthermore, the device proves applicable for measuring the magnetic center of other types of HEPS insertion devices, including Cryogenic undulators.Keywords
This publication has 13 references indexed in Scilit:
- Optimization of rotating coil system for magnetic center measurement and its application in high energy photon sourceMeasurement Science and Technology, 2023
- An efficient automatic positioning system design for batched magnets and magnetic field measurement system of HIAFNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- A laser tracker-based multilateration method for pre-alignment of High Energy Photon Source storage ringNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- A new laser-based monitoring method for the cryomodule components alignmentMeasurement Science and Technology, 2022
- A novel positioning method for Hall magnetic field measurement of heavy ion acceleratorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- CLIC pre-alignment — status and remaining challengesMeasurement Science and Technology, 2021
- The HEPS projectJournal of Synchrotron Radiation, 2018
- Transfer of the magnetic axis of an undulator to mechanical fiducial marks of a laser tracker systemNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Chinese high energy photon source and the test facilitySCIENTIA SINICA Physica, Mechanica & Astronomica, 2014
- Status of HEPS Insertion Devices Design