LZLuyan Zhang

Luyan Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luyan Zhang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Haoyue Yan

    Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, People’s Republic of China

    3 shared publications
  • Luping Yan

    Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, People’s Republic of China

    3 shared publications
  • Shang Lu

    Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, People’s Republic of China

    3 shared publications
  • Xiaolong Wang

    Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, People’s Republic of China

    3 shared publications
  • Yuanying Han

    Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, People’s Republic of China

    3 shared publications
  • Lan Dong

    Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, People’s Republic of China

    2 shared publications

Latest Publications

  • High-Precision Automated Alignment for Particle Accelerators: A Visual Aiming Angle Intersection Approach

    by Yubo Xing, Tong Wang, Jing Liang, Xiao Li, Chengyao Deng, Na Ma, Lin Cai, Zhiyong Ke, Zhenqiang He, Shang Lu, et al.

  • The design and application of magnetic landmark used for magnetic fiducialization of HEPS insertion devices*

    by Lingling Men, LiFang Zheng, Xiaoyang Liu, Lan Dong, Zhiyong Ke, Luyan Zhang, Xiaolong Wang, Bo Li, Tong Wang, Jing Liang, et al.

    Achieving high performance in synchrotron radiation light sources demands increased precision in fiducialization and alignment of insertion devices (IDs). Conventional sensor systems utilizing Hall probes for high-precision magnetic field measurements face limitations in determining the absolute position of the magnetic center of IDs. In this paper, the Magnetic Landmark (MLK), a novel solution based on a magnetized block structure, is designed to address this challenge. The MLK serves as an intermediary, establishing contact between the magnetic center of IDs and their externally accessible fiducials, thus enabling high-precision alignment. Through analysis of magnetic field distribution, self-calibration precision, and practical application of the MLK, the following conclusions are drawn: when the Hall probe is positioned within 0.5 mm of the magnetic field zero point inside the MLK, the measurement accuracy of the zero point for normal and skew quadrupole magnetic fields reaches 7 and 2 μm, respectively. Additionally, the self-measurement accuracy of the MLK is 10 and 4 μm in the transverse and vertical directions, respectively. These accuracies meet our usage requirements. The MLK demonstrates efficacy in aligning the magnetic center of High Energy Photon Source (HEPS) In-air undulators, achieving alignment accuracies of 16 μm in the transverse direction and 11 μm in the vertical direction, surpassing the 30 μm accuracy stipulated in the physical design. Furthermore, the device proves applicable for measuring the magnetic center of other types of HEPS insertion devices, including Cryogenic undulators.


  • Optimization of rotating coil system for magnetic center measurement and its application in high energy photon source

    by Luyan Zhang, Yuanying Han, Tong Wang, Lan Dong, Zhiyong Ke, Xiaolong Wang, Lingling Men, Luping Yan, Shang Lu, Xiaoyang Liu, et al.

    The Chinese high energy photon source is the fourth-generation light source that is currently under construction, with the booster being a significant component that has been completed by October 2022. In order to meet this timeline, 218 magnets requiring calibration were fitted with a rotating coil system and a three-coordinate measuring machine to optimize magnet center calibration. The rotating coil system is specially designed for magnetic center measurements. It employs a single-turn coil instead of the traditional complex compensated coil and uses a three-coordinate measuring machine imaging probe for precise positioning of the wire in space. This system has high accuracy, high speed, and high reliability. However, it is limited by the size of the three-coordinate measuring machine, meaning that larger magnets cannot be measured, thus limiting scalability. In September 2022, all of the magnets had been calibrated. This paper introduces the various aspects of coil design and examines the efficacy of employing three-coordinate measuring machine imaging for coil rotation center positioning and sag measurement, and provides a statistical analysis of calibration performance alongside mechanical calibration errors, the deviation between the magnet center and the mechanical center, and also a scatter analysis. Additionally, this paper also outlines the changes in the measuring time for each magnet, providing a reference for future magnet center calibration tasks.


  • A single-turn rotating coil magnetic center calibration system designed for high energy photon source

    by Luyan Zhang, Yuanying Han, Lan Dong, Tong Wang, Zhiyong Ke, Xiaolong Wang, Lingling Men, Luping Yan, Shang Lu, Xiaoyang Liu, et al.

    To ensure high-precision alignment of large quantities of magnets in Chinese high energy photon source, a high magnetic center measurement efficiency is required. To achieve this, a unique single-turn rotating coil magnetic center calibration system was designed, which simplifies the traditional multi-turn compensated coil with two sets of windings that can be connected. This design reduces measurement time significantly while increasing precision by incorporating a three-coordinate measuring machine. The study presents the system’s general design, mathematical theory, and test results. Tests replacing the coil and magnets and realigning them demonstrated that the precision and measurement efficiency meet the design requirements. The displacement between the magnetic and mechanical axes was within 20 μm, indicating good performance of the well-fabricated and tested ultra-high gradient quadrupole magnet. The optimized rotating coil system design reduces the entire procedure, including magnet installation and alignment, magnetic axis measurement, and magnetic center extraction to fixed points on the magnet, to only a few hours. Several magnets participating in pre-alignment were measured, and tests and practical operation resulted in small magnetic center displacements.