Abstract
Geosynthetics are often used to stabilize and/or reinforce flexible pavements. Heavily instrumented, full-scale field testing has been performed to investigate the behavior of geosynthetics in flexible pavement applications (under dynamic traffic loads). Geosynthetics are instrumented to collect geosynthetic strain data that will support the development of mechanistic-empirical models for pavement design. The type of gage selected, and the methods used to bond, wire, and protect a strain gage must be carefully considered to ensure strain is measured accurately under dynamic loads, and the gage survives harsh construction conditions. The purpose of this paper is to discuss key issues regarding gage selection and preparation, and detail methods used to calibrate and install foil strain gages, wire extensometers, and inductance coils for the purpose of monitoring strain on geosynthetics in full-scale, flexible pavement field tests.

This publication has 8 references indexed in Scilit: