Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients
- 29 September 2006
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 17 (3) , 603-609
Abstract
Cardiac multi-detector-row computed tomography (MDCT) angiography has shown high levels of sensitivity and especially negative predictive value regarding the diagnosis of coronary artery disease (CAD). This study was designed to determine the value of a 64-slice-MDCT scanner in comparison to invasive coronary angiography for the detection of CAD in a population of symptomatic patients. Fifty-one patients with suspected CAD underwent conventional coronary angiography and ECG-gated cardiac 64-slice-MDCT angiography with a rotation time of 330 ms, a collimation of 64×0.6 mm and a slice thickness of 0.75 mm. Blinded patient- and segment-based analysis was performed for the detection of stenoses ≥70% of the vessel lumen. 95% of all coronary segments were assessable by MDCT angiography. Patient-based (segment-based) analysis revealed a sensitivity of 97.8% (86.7%), specificity of 50% (95.2%), positive predictive value of 93.6% (75.2%) and negative predictive value of 75% (97.7%). Inter-rater agreement revealed a kappa-value of 0.558 (0.722). In this symptomatic patient group a 64-slice-MDCT scanner shows good agreement on a segment-based analysis but only moderate agreement on a patient-based analysis. The diagnostic accuracy of 64-slice-MDCT coronary angiography is negatively influenced by the high pre-test probability of this symptomatic patient collective.Keywords
This publication has 29 references indexed in Scilit:
- High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary AngiographyCirculation, 2005
- Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed TomographyJACC, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJACC, 2005
- Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolutionHeart, 2005
- Coronary vessel visualization using true 16-row multi-slice computed tomography technologyThe International Journal of Cardiovascular Imaging, 2005
- Coronary CT angiography in symptomatic patientsEuropean Radiology Supplements, 2005
- Performance Evaluation of a 64-Slice CT System with z-Flying Focal SpotRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical resultsJACC, 2004
- Complications associated with cardiac catheterization and angiographyCatheterization and Cardiovascular Diagnosis, 1982
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975