Endocardial Implantation of a Cardioverter Defibrillator in Early Childhood
- 8 December 2005
- journal article
- case report
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (12) , 1381-1383
Abstract
Experience in endovascular/endocardial techniques for implanting implantable cardioverter defibrillators in early childhood is limited. Potentially, this type of approach could limit the surgical risk, while increasing ICD therapy efficacy. The safety and feasibility of adopting a complete endovascular/endocardial approach for implanting ICDs is assessed by considering the cases of two young children. Two boys, aged 3 and 6 years, were implanted with ICD for a history of syncope and documented ventricular tachycardia (VT). A complete endovascular/endocardial approach was adopted consisting of positioning a bipolar pacing and sensing lead in the right ventricular (RV) apex with intravascular redundancy forming a loop in the inferior vena cava (IVC), and a caval coil placed in the IVC. Sensing values (7-8 mV), pacing threshold (0.5-0.6 V/0.5 msec), and defibrillation testing (case 1 = 10 J, case 2 = 20 J) were all acceptable. During follow-up, in both cases ICD intervened correctly. In one case, 16 months after implantation, because of change in the IVC coil-active can vector, the IVC coil was effectively repositioned to a more distal position. A complete endovascular/endocardial ICD implantation technique in early childhood is both feasible and safe. This approach avoids thoracotomy and ensures ICD therapy efficacy.Keywords
This publication has 8 references indexed in Scilit:
- Endocardial Implantation of a Cardioverter-Defibrillator in a 13-Month-Old Child Affected by Long-QT Syndrome and SyndactylyCirculation, 2004
- Letter to the EditorPacing and Clinical Electrophysiology, 2001
- Nonthoracotomy Implantable Cardioverter Defibrillator Placement in Children: Use of Subcutaneous Array Leads and Abdominally Placed Implantable Cardioverter Defibrillators in ChildrenJournal of Cardiovascular Electrophysiology, 2001
- Inferior Vena Cava Loop of the Implantable Cardioverter Defibrillator Endocardial Lead: A Possible Solution to the Growth Problem in Pediatric ImplantationPacing and Clinical Electrophysiology, 2000
- Implantable Cardioverter-Defibrillators in Children: A Single-Institutional ExperienceThe Annals of Thoracic Surgery, 1998
- Risk Factors for Venous Obstruction in Children with Transvenous Pacing LeadsPacing and Clinical Electrophysiology, 1997
- Implantation and Follow-Up of a Third-Generation Cardioverter Defibrillator: Comparison of Epicardial and Nonthoracotomy Defibrillation Lead SystemJournal of Interventional Cardiology, 1995
- Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society.Circulation, 1993