Iodine concentration of healthy lymph nodes of neck, axilla, and groin in dual-energy computed tomography
- 16 February 2020
- journal article
- review article
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (11) , 1505-1511
Abstract
Background: Lymph nodes (LN) are examined in every computed tomography (CT) scan. Until now, an evaluation is only possible based on morphological criteria. With dual-energy CT (DECT) systems, iodine concentration (IC) can be measured which could conduct in an improved diagnostic evaluation of LNs. Purpose: To define standard values for IC of cervical, axillary, and inguinal LNs in DECT. Material and Methods: Imaging data of 297 patients who received a DECT scan of the neck, thorax, abdomen–pelvis, or a combination of those in a portal-venous phase were retrospectively collected from the institutional PACS. No present history of malignancy, inflammation, or trauma in the examined region was present. For each examined region, the data of 99 patients were used. The IC of the three largest LNs, the main artery, the main vein, and a local muscle of the examined area was measured, respectively. Results: Normalization of the IC of LNs to the artery, vein, muscle, or a combination of those did not lead to a decreased value-range. The smallest range and confidence interval (CI) of IC was found when using absolute values of IC for each region. Hereby, mean values (95% CI) for IC of LN were found: 2.09 mg/mL (2.00–2.18 mg/mL) for neck, 1.24 mg/mL (1.16–1.33 mg/mL) for axilla, and 1.11 mg/mL (1.04–1.17 mg/mL) for groin. Conclusion: The present study suggests standard values for IC of LNs in dual-layer CT could be used to differentiate between healthy and pathological lymph nodes, considering the used contrast injection protocol.Keywords
This publication has 22 references indexed in Scilit:
- Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical ApplicationsRadiology, 2015
- Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal MassesAmerican Journal of Roentgenology, 2012
- Iodine removal in intravenous dual-energy CT-cholangiography: Is virtual non-enhanced imaging effective to replace true non-enhanced imaging?European Journal of Radiology, 2012
- Clinical Utility of Dual-Energy CT for Evaluation of Tophaceous GoutRadioGraphics, 2011
- Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scannerMedical Physics, 2011
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- TU‐E‐210A‐03: A Double‐Layer Detector, Dual‐Energy CT — Principles, Advantages and ApplicationsMedical Physics, 2009
- Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical ExperienceInvestigative Radiology, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureThe New England journal of medicine, 2007
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005