Sophie Ostmeier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sophie Ostmeier has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Greg Zaharchuk
Department of Radiology Stanford University Palo Alto California USA
3 shared publications - Bin Jiang
Stanford University
2 shared publications Brian Axelrod
Stanford University, Stanford, California, USA
2 shared publications- Gregory W. Albers
Stanford Stroke Center, Stanford University, Palo Alto, CA
2 shared publications - Guang Yang
Bioengineering Department and Imperial-X, Imperial College London, London, UK
2 shared publications - Jeremy Josef Heit
Department of Interventional Neuroradiology (G.W.A., J.J.H.), Stanford Medical Center, Palo Alto, California
2 shared publications
Latest Publications
- 1 October 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (1) , e240137
Prediction of Ischemic Stroke Functional Outcomes from Acute-Phase Noncontrast CT and Clinical Information
A deep learning model fusing noncontrast-enhanced CT and clinical information outperformed an imaging-only model and a clinical information–only model and performed similarly to MRI-based models in predicting 90-day stroke functional outcomes.
- 1 October 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (1) , e240137
Prediction of Ischemic Stroke Functional Outcomes from Acute-Phase Noncontrast CT and Clinical Information
A deep learning model fusing noncontrast-enhanced CT and clinical information outperformed an imaging-only model and a clinical information–only model and performed similarly to MRI-based models in predicting 90-day stroke functional outcomes.
- 1 February 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (1) , 53-59
Random expert sampling for deep learning segmentation of acute ischemic stroke on non-contrast CT
Background: Outlining acutely infarcted tissue on non-contrast CT is a challenging task for which human inter-reader agreement is limited. We explored two different methods for training a supervised deep learning algorithm: one that used a segmentation defined by majority vote among experts and another that trained randomly on separate individual expert segmentations. Methods: The data set consisted of 260 non-contrast CT studies in 233 patients with acute ischemic stroke recruited from the multicenter DEFUSE 3 (Endovascular Therapy Following Imaging Evaluation for Ischemic Stroke 3) trial. Additional external validation was performed using 33 patients with matched stroke onset times from the University Hospital Lausanne. A benchmark U-Net was trained on the reference annotations of three experienced neuroradiologists to segment ischemic brain tissue using majority vote and random expert sampling training schemes. The median of volume, overlap, and distance segmentation metrics were determined for agreement in lesion segmentations between (1) three experts, (2) the majority model and each expert, and (3) the random model and each expert. The two sided Wilcoxon signed rank test was used to compare performances (1) to 2) and (1) to (3). We further compared volumes with the 24 hour follow-up diffusion weighted imaging (DWI, final infarct core) and correlations with clinical outcome (modified Rankin Scale (mRS) at 90 days) with the Spearman method. Results: The random model outperformed the inter-expert agreement ((1) to (2)) and the majority model ((1) to (3)) (dice 0.51±0.04 vs 0.36±0.05 (P<0.0001) vs 0.45±0.05 (P<0.0001)). The random model predicted volume correlated with clinical outcome (0.19, P<0.05), whereas the median expert volume and majority model volume did not. There was no significant difference when comparing the volume correlations between random model, median expert volume, and majority model to 24 hour follow-up DWI volume (P>0.05, n=51). Conclusion: The random model for ischemic injury delineation on non-contrast CT surpassed the inter-expert agreement ((1) to (2)) and the performance of the majority model ((1) to (3)). We showed that the random model volumetric measures of the model were consistent with 24 hour follow-up DWI.
- 1 February 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (1) , 53-59
Random expert sampling for deep learning segmentation of acute ischemic stroke on non-contrast CT
Background: Outlining acutely infarcted tissue on non-contrast CT is a challenging task for which human inter-reader agreement is limited. We explored two different methods for training a supervised deep learning algorithm: one that used a segmentation defined by majority vote among experts and another that trained randomly on separate individual expert segmentations. Methods: The data set consisted of 260 non-contrast CT studies in 233 patients with acute ischemic stroke recruited from the multicenter DEFUSE 3 (Endovascular Therapy Following Imaging Evaluation for Ischemic Stroke 3) trial. Additional external validation was performed using 33 patients with matched stroke onset times from the University Hospital Lausanne. A benchmark U-Net was trained on the reference annotations of three experienced neuroradiologists to segment ischemic brain tissue using majority vote and random expert sampling training schemes. The median of volume, overlap, and distance segmentation metrics were determined for agreement in lesion segmentations between (1) three experts, (2) the majority model and each expert, and (3) the random model and each expert. The two sided Wilcoxon signed rank test was used to compare performances (1) to 2) and (1) to (3). We further compared volumes with the 24 hour follow-up diffusion weighted imaging (DWI, final infarct core) and correlations with clinical outcome (modified Rankin Scale (mRS) at 90 days) with the Spearman method. Results: The random model outperformed the inter-expert agreement ((1) to (2)) and the majority model ((1) to (3)) (dice 0.51±0.04 vs 0.36±0.05 (P<0.0001) vs 0.45±0.05 (P<0.0001)). The random model predicted volume correlated with clinical outcome (0.19, P<0.05), whereas the median expert volume and majority model volume did not. There was no significant difference when comparing the volume correlations between random model, median expert volume, and majority model to 24 hour follow-up DWI volume (P>0.05, n=51). Conclusion: The random model for ischemic injury delineation on non-contrast CT surpassed the inter-expert agreement ((1) to (2)) and the performance of the majority model ((1) to (3)). We showed that the random model volumetric measures of the model were consistent with 24 hour follow-up DWI.
- Top Cited Papers
- 1 September 2023
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (9) , 2316-2327
Functional Outcome Prediction in Acute Ischemic Stroke Using a Fused Imaging and Clinical Deep Learning Model
BACKGROUND: Predicting long-term clinical outcome based on the early acute ischemic stroke information is valuable for prognostication, resource management, clinical trials, and patient expectations. Current methods require subjective decisions about which imaging features to assess and may require time-consuming postprocessing. This study’s goal was to predict ordinal 90-day modified Rankin Scale (mRS) score in acute ischemic stroke patients by fusing a Deep Learning model of diffusion-weighted imaging images and clinical information from the acute period. METHODS: A total of 640 acute ischemic stroke patients who underwent magnetic resonance imaging within 1 to 7 days poststroke and had 90-day mRS follow-up data were randomly divided into 70% (n=448) for model training, 15% (n=96) for validation, and 15% (n=96) for internal testing. Additionally, external testing on a cohort from Lausanne University Hospital (n=280) was performed to further evaluate model generalization. Accuracy for ordinal mRS, accuracy within ±1 mRS category, mean absolute prediction error, and determination of unfavorable outcome (mRS score >2) were evaluated for clinical only, imaging only, and 2 fused clinical-imaging models. RESULTS: The fused models demonstrated superior performance in predicting ordinal mRS score and unfavorable outcome in both internal and external test cohorts when compared with the clinical and imaging models. For the internal test cohort, the top fused model had the highest area under the curve of 0.92 for unfavorable outcome prediction and the lowest mean absolute error (0.96 [95% CI, 0.77–1.16]), with the highest proportion of mRS score predictions within ±1 category (79% [95% CI, 71%–88%]). On the external Lausanne University Hospital cohort, the best fused model had an area under the curve of 0.90 for unfavorable outcome prediction and outperformed other models with an mean absolute error of 0.90 (95% CI, 0.79–1.01), and the highest percentage of mRS score predictions within ±1 category (83% [95% CI, 78%–87%]). CONCLUSIONS: A Deep Learning-based imaging model fused with clinical variables can be used to predict 90-day stroke outcome with reduced subjectivity and user burden.
- 1 September 2023
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (9) , 2316-2327
Top Cited PapersFunctional Outcome Prediction in Acute Ischemic Stroke Using a Fused Imaging and Clinical Deep Learning Model
BACKGROUND: Predicting long-term clinical outcome based on the early acute ischemic stroke information is valuable for prognostication, resource management, clinical trials, and patient expectations. Current methods require subjective decisions about which imaging features to assess and may require time-consuming postprocessing. This study’s goal was to predict ordinal 90-day modified Rankin Scale (mRS) score in acute ischemic stroke patients by fusing a Deep Learning model of diffusion-weighted imaging images and clinical information from the acute period. METHODS: A total of 640 acute ischemic stroke patients who underwent magnetic resonance imaging within 1 to 7 days poststroke and had 90-day mRS follow-up data were randomly divided into 70% (n=448) for model training, 15% (n=96) for validation, and 15% (n=96) for internal testing. Additionally, external testing on a cohort from Lausanne University Hospital (n=280) was performed to further evaluate model generalization. Accuracy for ordinal mRS, accuracy within ±1 mRS category, mean absolute prediction error, and determination of unfavorable outcome (mRS score >2) were evaluated for clinical only, imaging only, and 2 fused clinical-imaging models. RESULTS: The fused models demonstrated superior performance in predicting ordinal mRS score and unfavorable outcome in both internal and external test cohorts when compared with the clinical and imaging models. For the internal test cohort, the top fused model had the highest area under the curve of 0.92 for unfavorable outcome prediction and the lowest mean absolute error (0.96 [95% CI, 0.77–1.16]), with the highest proportion of mRS score predictions within ±1 category (79% [95% CI, 71%–88%]). On the external Lausanne University Hospital cohort, the best fused model had an area under the curve of 0.90 for unfavorable outcome prediction and outperformed other models with an mean absolute error of 0.90 (95% CI, 0.79–1.01), and the highest percentage of mRS score predictions within ±1 category (83% [95% CI, 78%–87%]). CONCLUSIONS: A Deep Learning-based imaging model fused with clinical variables can be used to predict 90-day stroke outcome with reduced subjectivity and user burden.
- 10 August 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 90, 102927
USE-Evaluator: Performance metrics for medical image segmentation models supervised by uncertain, small or empty reference annotations in neuroimaging
- 10 August 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 90, 102927
USE-Evaluator: Performance metrics for medical image segmentation models supervised by uncertain, small or empty reference annotations in neuroimaging
- 2 March 2022
- Published by Elsevier
- p. 587-602
Translational research in spinal cord injury – What is in the future?
- 2 March 2022
- Published by Elsevier
- p. 587-602
Translational research in spinal cord injury – What is in the future?
- 16 February 2020
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (11) , 1505-1511
Iodine concentration of healthy lymph nodes of neck, axilla, and groin in dual-energy computed tomography
Background: Lymph nodes (LN) are examined in every computed tomography (CT) scan. Until now, an evaluation is only possible based on morphological criteria. With dual-energy CT (DECT) systems, iodine concentration (IC) can be measured which could conduct in an improved diagnostic evaluation of LNs. Purpose: To define standard values for IC of cervical, axillary, and inguinal LNs in DECT. Material and Methods: Imaging data of 297 patients who received a DECT scan of the neck, thorax, abdomen–pelvis, or a combination of those in a portal-venous phase were retrospectively collected from the institutional PACS. No present history of malignancy, inflammation, or trauma in the examined region was present. For each examined region, the data of 99 patients were used. The IC of the three largest LNs, the main artery, the main vein, and a local muscle of the examined area was measured, respectively. Results: Normalization of the IC of LNs to the artery, vein, muscle, or a combination of those did not lead to a decreased value-range. The smallest range and confidence interval (CI) of IC was found when using absolute values of IC for each region. Hereby, mean values (95% CI) for IC of LN were found: 2.09 mg/mL (2.00–2.18 mg/mL) for neck, 1.24 mg/mL (1.16–1.33 mg/mL) for axilla, and 1.11 mg/mL (1.04–1.17 mg/mL) for groin. Conclusion: The present study suggests standard values for IC of LNs in dual-layer CT could be used to differentiate between healthy and pathological lymph nodes, considering the used contrast injection protocol.
- 16 February 2020
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (11) , 1505-1511
Iodine concentration of healthy lymph nodes of neck, axilla, and groin in dual-energy computed tomography
Background: Lymph nodes (LN) are examined in every computed tomography (CT) scan. Until now, an evaluation is only possible based on morphological criteria. With dual-energy CT (DECT) systems, iodine concentration (IC) can be measured which could conduct in an improved diagnostic evaluation of LNs. Purpose: To define standard values for IC of cervical, axillary, and inguinal LNs in DECT. Material and Methods: Imaging data of 297 patients who received a DECT scan of the neck, thorax, abdomen–pelvis, or a combination of those in a portal-venous phase were retrospectively collected from the institutional PACS. No present history of malignancy, inflammation, or trauma in the examined region was present. For each examined region, the data of 99 patients were used. The IC of the three largest LNs, the main artery, the main vein, and a local muscle of the examined area was measured, respectively. Results: Normalization of the IC of LNs to the artery, vein, muscle, or a combination of those did not lead to a decreased value-range. The smallest range and confidence interval (CI) of IC was found when using absolute values of IC for each region. Hereby, mean values (95% CI) for IC of LN were found: 2.09 mg/mL (2.00–2.18 mg/mL) for neck, 1.24 mg/mL (1.16–1.33 mg/mL) for axilla, and 1.11 mg/mL (1.04–1.17 mg/mL) for groin. Conclusion: The present study suggests standard values for IC of LNs in dual-layer CT could be used to differentiate between healthy and pathological lymph nodes, considering the used contrast injection protocol.