Sensitivity analysis of a double-parallelogram based RCM mechanism used for MIS robots
- 15 February 2023
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (20) , 4813-4827
Abstract
Parallelogram-based remote center-of-motion (RCM) mechanisms are extensively used to design robots for minimally invasive surgery (MIS). For their kinematic modeling, classically, it is assumed that link parameters of the opposite sides of constituting parallelograms are equal which made the RCM an invariant point and simplified the prescribed modeling process. However, link parameter equality does not exist in actual practice due to the inevitable constraints of manufacturing, assembly and testing/measurement, etc. Consequently, the RCM and surgical end-effector deviate from their theoretically designed positions. This paper introduces a novel approach to model the kinematics of parallelogram-based mechanisms by accounting for the error in manufactured link parameters. Additionally, it works out the types, possible ways, order, and nature of the said deviation. Further, a double-parallelogram-based RCM mechanism is adopted to demonstrate the proposed concept, and a prototype of the same is manufactured using laser micromachining and rapid prototyping techniques. Thereafter, the developed kinematic models are validated both analytically and physically. In contrast to the results given by the conventional kinematic modeling approach, the results obtained through the proposed approach and performed experiment showed better agreement with each other. The sensitivity of RCM and surgical end-effector to the inequalities, involved in the manufactured prototype, is revealed through several plots in the Matlab environment. A significant improvement in positional accuracy of the RCM and surgical end-effector have been achieved. It proves the efficacy of the presented method and it is believed that it applies to other parallelogram-based mechanisms as well.Keywords
This publication has 27 references indexed in Scilit:
- Kinematics of a Fully-Decoupled Remote Center-of-Motion Parallel Manipulator for Minimally Invasive SurgeryJournal of Medical Devices, 2012
- Kinematic design considerations for minimally invasive surgical robots: an overviewThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Kinematic Analysis and Optimization of a Novel Robot for Surgical Tool ManipulationJournal of Medical Devices, 2008
- Medical robotics in computer-integrated surgeryIEEE Transactions on Robotics and Automation, 2003
- Robotics for telesurgery: second generation Berkeley/UCSF laparoscopic telesurgical workstation and looking towards the future applicationsIndustrial Robot: the international journal of robotics research and application, 2003
- A Steady-Hand Robotic System for Microsurgical AugmentationThe International Journal of Robotics Research, 1999
- A New Safe Laparoscopic Manipulator System with a Five-Bar Linkage Mechanism and an Optical ZoomComputer Aided Surgery, 1999
- A modular surgical robotic system for image guided percutaneous procedures1998
- A telerobotic assistant for laparoscopic surgeryIEEE Engineering in Medicine and Biology Magazine, 1995
- Robotically assisted laparoscopic surgerySurgical Endoscopy, 1994