Jitendra Prasad Khatait
Research Subjects
Research Interests
Jitendra Prasad Khatait has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Ronald G. K. M. Aarts
University of Twente
8 shared publications - Dannis M. Brouwer
University of Twente
7 shared publications - Justus Laurens Herder
Delft University of Technology
6 shared publications J. P. Meijaard
Mechanical Automation and Mechatronics, Faculty of Engineering Technology, University of Twente, AE Enschede 7500, The Netherlands
3 shared publicationsVaran Gupta
Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, India
3 shared publications- Amanpreet Singh
Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, Delhi, India
2 shared publications
Latest Publications
- 3 July 2026
- Published by Springer Nature
- p. 94-102
Design and Mobility Assessment of a Flexure-Based Coupling Using Screw Algebra
- 3 July 2026
- Published by Springer Nature
- p. 94-102
Design and Mobility Assessment of a Flexure-Based Coupling Using Screw Algebra
- 2 January 2026
- Published by Springer Nature
- p. 1-9
Design and Analysis of Flexure-Based Screw Mechanism
- 2 January 2026
- Published by Springer Nature
- p. 1-9
Design and Analysis of Flexure-Based Screw Mechanism
- 2 January 2026
- Published by Springer Nature
- p. 115-121
Development of Large Deflection Single DOF Compliant Rotary Joint
- 2 January 2026
- Published by Springer Nature
- p. 115-121
Development of Large Deflection Single DOF Compliant Rotary Joint
- 22 December 2025
- Published by Springer Nature in Transactions of the Indian National Academy of Engineering
- Vol. 11 (1) , 113-120
Electro-Mechanical Analysis of Double Fillet Rail Geometry in an Augmented Railgun
- 22 December 2025
- Published by Springer Nature in Transactions of the Indian National Academy of Engineering
- Vol. 11 (1) , 113-120
Electro-Mechanical Analysis of Double Fillet Rail Geometry in an Augmented Railgun
- 21 July 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 238 (6) , 2267-2282
RCM adjustment for a double-parallelogram based RCM mechanism used for MIS robots
The inevitable errors in the manufacturing, assembly, and testing of a remote center-of-motion (RCM) mechanism lead to the erroneous link parameters which deviate its geometry. Consequently, the motion, as well as the force, become non-zero at the entry port to the patient’s body which is undesirable. To address this issue, the current work first presents the accurate kinematic model of the RCM of an exemplary double-parallelogram-based RCM mechanism. Thereafter, it introduces the RCM adjustment concept and a flexure-based compliant mechanism to nullify/minimize the said deviation. For the analytical design of the flexure element, this paper makes the required design calculations and performs the finite element analysis. It is followed by the disclosure of the RCM Adjustment System and a systematized method of RCM adjustment for a mechanically constrained RCM device. The devised system is based on the prescribed compliant mechanism design and is advantageous, over the traditional RCM adjustments. The potential of the proposed concept lies in the fact that it is not limited to the adopted mechanism only rather, it is extendable to other mechanisms as well which was missing in the prior art. In addition, it offers a more simplified and economical design. Further, an initial prototype of the exemplary mechanism is manufactured using laser micromachining and rapid prototyping techniques. Both analytical as well as physical validations have been performed which proved the efficacy of the proposed kinematic modeling concept. Furthermore, the prototype of the introduced RCM Adjustment System is manufactured as a single-piece design which demonstrated its effectiveness. The preferred embodiment of the same is the said double-parallelogram-based RCM mechanism which is most widely used for robot-assisted minimally invasive surgery (RAMIS). It is designed in a SolidWorks environment and manufactured using Al6101-T6 and SS304 as link material, and a variety of standard elements.
- 21 July 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 238 (6) , 2267-2282
RCM adjustment for a double-parallelogram based RCM mechanism used for MIS robots
The inevitable errors in the manufacturing, assembly, and testing of a remote center-of-motion (RCM) mechanism lead to the erroneous link parameters which deviate its geometry. Consequently, the motion, as well as the force, become non-zero at the entry port to the patient’s body which is undesirable. To address this issue, the current work first presents the accurate kinematic model of the RCM of an exemplary double-parallelogram-based RCM mechanism. Thereafter, it introduces the RCM adjustment concept and a flexure-based compliant mechanism to nullify/minimize the said deviation. For the analytical design of the flexure element, this paper makes the required design calculations and performs the finite element analysis. It is followed by the disclosure of the RCM Adjustment System and a systematized method of RCM adjustment for a mechanically constrained RCM device. The devised system is based on the prescribed compliant mechanism design and is advantageous, over the traditional RCM adjustments. The potential of the proposed concept lies in the fact that it is not limited to the adopted mechanism only rather, it is extendable to other mechanisms as well which was missing in the prior art. In addition, it offers a more simplified and economical design. Further, an initial prototype of the exemplary mechanism is manufactured using laser micromachining and rapid prototyping techniques. Both analytical as well as physical validations have been performed which proved the efficacy of the proposed kinematic modeling concept. Furthermore, the prototype of the introduced RCM Adjustment System is manufactured as a single-piece design which demonstrated its effectiveness. The preferred embodiment of the same is the said double-parallelogram-based RCM mechanism which is most widely used for robot-assisted minimally invasive surgery (RAMIS). It is designed in a SolidWorks environment and manufactured using Al6101-T6 and SS304 as link material, and a variety of standard elements.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (3) , 936-942
Armature Design Recommendations Based on Action Parameters
Force resolution over a C-armature reveals a large Lorentz force that acts to push the armature into rails. Large contact forces lead to a multitude of problems and efficiency losses. This article introduces a set of new parameters called action parameters (APs): armature action and action constant. These parameters optimize armature–rail (A/R) contact force to desired levels and improve muzzle velocity and launcher efficiency. The kinetic energy increases by 7.56 times for the case considered in this article. However, issues regarding loss of compliance and contact force fluctuations arising from optimizing C-armature unveil the need to develop a new armature design. It is recommended that the new armature should have a monolithic design, mechanical load carrying capacity, compliance, and a short current path. Such a hybrid armature design is proposed, and the design process is described.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (3) , 936-942
Armature Design Recommendations Based on Action Parameters
Force resolution over a C-armature reveals a large Lorentz force that acts to push the armature into rails. Large contact forces lead to a multitude of problems and efficiency losses. This article introduces a set of new parameters called action parameters (APs): armature action and action constant. These parameters optimize armature–rail (A/R) contact force to desired levels and improve muzzle velocity and launcher efficiency. The kinetic energy increases by 7.56 times for the case considered in this article. However, issues regarding loss of compliance and contact force fluctuations arising from optimizing C-armature unveil the need to develop a new armature design. It is recommended that the new armature should have a monolithic design, mechanical load carrying capacity, compliance, and a short current path. Such a hybrid armature design is proposed, and the design process is described.
- 15 February 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (20) , 4813-4827
Sensitivity analysis of a double-parallelogram based RCM mechanism used for MIS robots
Parallelogram-based remote center-of-motion (RCM) mechanisms are extensively used to design robots for minimally invasive surgery (MIS). For their kinematic modeling, classically, it is assumed that link parameters of the opposite sides of constituting parallelograms are equal which made the RCM an invariant point and simplified the prescribed modeling process. However, link parameter equality does not exist in actual practice due to the inevitable constraints of manufacturing, assembly and testing/measurement, etc. Consequently, the RCM and surgical end-effector deviate from their theoretically designed positions. This paper introduces a novel approach to model the kinematics of parallelogram-based mechanisms by accounting for the error in manufactured link parameters. Additionally, it works out the types, possible ways, order, and nature of the said deviation. Further, a double-parallelogram-based RCM mechanism is adopted to demonstrate the proposed concept, and a prototype of the same is manufactured using laser micromachining and rapid prototyping techniques. Thereafter, the developed kinematic models are validated both analytically and physically. In contrast to the results given by the conventional kinematic modeling approach, the results obtained through the proposed approach and performed experiment showed better agreement with each other. The sensitivity of RCM and surgical end-effector to the inequalities, involved in the manufactured prototype, is revealed through several plots in the Matlab environment. A significant improvement in positional accuracy of the RCM and surgical end-effector have been achieved. It proves the efficacy of the presented method and it is believed that it applies to other parallelogram-based mechanisms as well.
- 15 February 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 237 (20) , 4813-4827
Sensitivity analysis of a double-parallelogram based RCM mechanism used for MIS robots
Parallelogram-based remote center-of-motion (RCM) mechanisms are extensively used to design robots for minimally invasive surgery (MIS). For their kinematic modeling, classically, it is assumed that link parameters of the opposite sides of constituting parallelograms are equal which made the RCM an invariant point and simplified the prescribed modeling process. However, link parameter equality does not exist in actual practice due to the inevitable constraints of manufacturing, assembly and testing/measurement, etc. Consequently, the RCM and surgical end-effector deviate from their theoretically designed positions. This paper introduces a novel approach to model the kinematics of parallelogram-based mechanisms by accounting for the error in manufactured link parameters. Additionally, it works out the types, possible ways, order, and nature of the said deviation. Further, a double-parallelogram-based RCM mechanism is adopted to demonstrate the proposed concept, and a prototype of the same is manufactured using laser micromachining and rapid prototyping techniques. Thereafter, the developed kinematic models are validated both analytically and physically. In contrast to the results given by the conventional kinematic modeling approach, the results obtained through the proposed approach and performed experiment showed better agreement with each other. The sensitivity of RCM and surgical end-effector to the inequalities, involved in the manufactured prototype, is revealed through several plots in the Matlab environment. A significant improvement in positional accuracy of the RCM and surgical end-effector have been achieved. It proves the efficacy of the presented method and it is believed that it applies to other parallelogram-based mechanisms as well.
- 5 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (10) , 3468-3472
Design and Analysis of Hybrid Armature for Electromagnetic Launch Technology
Velocity skin effect (VSE) and subsequent current melt wave (CMW) is one of the most prominent causes of transition in an electromagnetic launch (EML) technology. Extensive research on the phenomenon led to the development of a monolithic C armature design that provides optimum contact pressure and a contact region at the armature–rail (A/R) interface. However, in the working velocity regime of an EML, frictional heating at the contact interface dominates wear, heat generation, and contact transition. Because of a long current path, the C armature generates contact forces of the same magnitude as the thrust force. A hybrid armature design is proposed based on previous recommendations that provide mechanical load carrying capacity, compliance, and a monolithic design akin to a C armature while providing a short current path to reduce frictional loss. The resulting hybrid armature has 33% less parasitic mass that delivers 22% higher kinetic energy to the payload.
- 5 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (10) , 3468-3472
Design and Analysis of Hybrid Armature for Electromagnetic Launch Technology
Velocity skin effect (VSE) and subsequent current melt wave (CMW) is one of the most prominent causes of transition in an electromagnetic launch (EML) technology. Extensive research on the phenomenon led to the development of a monolithic C armature design that provides optimum contact pressure and a contact region at the armature–rail (A/R) interface. However, in the working velocity regime of an EML, frictional heating at the contact interface dominates wear, heat generation, and contact transition. Because of a long current path, the C armature generates contact forces of the same magnitude as the thrust force. A hybrid armature design is proposed based on previous recommendations that provide mechanical load carrying capacity, compliance, and a monolithic design akin to a C armature while providing a short current path to reduce frictional loss. The resulting hybrid armature has 33% less parasitic mass that delivers 22% higher kinetic energy to the payload.
- 14 May 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 236 (16) , 9293-9305
Mechanism for tension adjustment in tendon driven remote center-of-motion mechanism for minimally invasive surgery
Tendon drive is used for transmission design in applications ranging from wearable rehabilitation and surgical robots to industrial robots. For their efficient operation, one of the principal design requirements is to have adequate tension in the tendon element. This paper introduces a novel mechanism for tension adjustment using a secondary cable-pulley arrangement via a lever mechanism. An adjustment in a tension spring applies a force in the tendon element meant for the transmission of remote centre-of-motion (RCM) mechanism for medical robotic application. Thereafter, the current work presents the kinematic and force analyses of the proposed concept along with a series of plots of various mechanism parameters. The variation of these parameters is in good agreement with the physical motion of the devised mechanism. As compared to the conventional methods of tension adjustment, the proposed concept is a better solution for problems that arise due to low manufacturing tolerances and the need for independent tension adjustment in a multi degrees-of-freedom tendon driven RCM mechanism. In the preferred embodiment, it is proposed to use cables (wire-ropes) as tendon elements to drive a mechanically constrained double-parallelogram-based RCM mechanism which is extensively used for Minimally Invasive Surgery. From this implementation, it is learnt that the presented mechanism can be implemented in several configurations. However, this paper presents the preferred embodiment only which meets the demand, of invariant tendon length, of the RCM mechanism under consideration. An initial prototype is made from acrylic sheets, PLA material, and standard elements (like bearings, pulleys, aluminum pins, 0.5 mm stainless-steel wire-rope, etc.) using laser micromachining and 3D printing.
- 14 May 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 236 (16) , 9293-9305
Mechanism for tension adjustment in tendon driven remote center-of-motion mechanism for minimally invasive surgery
Tendon drive is used for transmission design in applications ranging from wearable rehabilitation and surgical robots to industrial robots. For their efficient operation, one of the principal design requirements is to have adequate tension in the tendon element. This paper introduces a novel mechanism for tension adjustment using a secondary cable-pulley arrangement via a lever mechanism. An adjustment in a tension spring applies a force in the tendon element meant for the transmission of remote centre-of-motion (RCM) mechanism for medical robotic application. Thereafter, the current work presents the kinematic and force analyses of the proposed concept along with a series of plots of various mechanism parameters. The variation of these parameters is in good agreement with the physical motion of the devised mechanism. As compared to the conventional methods of tension adjustment, the proposed concept is a better solution for problems that arise due to low manufacturing tolerances and the need for independent tension adjustment in a multi degrees-of-freedom tendon driven RCM mechanism. In the preferred embodiment, it is proposed to use cables (wire-ropes) as tendon elements to drive a mechanically constrained double-parallelogram-based RCM mechanism which is extensively used for Minimally Invasive Surgery. From this implementation, it is learnt that the presented mechanism can be implemented in several configurations. However, this paper presents the preferred embodiment only which meets the demand, of invariant tendon length, of the RCM mechanism under consideration. An initial prototype is made from acrylic sheets, PLA material, and standard elements (like bearings, pulleys, aluminum pins, 0.5 mm stainless-steel wire-rope, etc.) using laser micromachining and 3D printing.
- 20 December 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 236 (8) , 4085-4092
Flexure based gripper to grasp hollow objects by internal surface interaction
The paper focuses on the design, development, and evaluation of a gripper intended to hold hollow objects by interacting with the inner surface. The gripper moves towards the inside of the hollow object and grips it using the friction forces applied on the surface of the object. The design also ensures the application of variable normal forces on the surface of the object to be grasped. The mathematical architecture is verified using prototypes and experiments.
- 20 December 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 236 (8) , 4085-4092
Flexure based gripper to grasp hollow objects by internal surface interaction
The paper focuses on the design, development, and evaluation of a gripper intended to hold hollow objects by interacting with the inner surface. The gripper moves towards the inside of the hollow object and grips it using the friction forces applied on the surface of the object. The design also ensures the application of variable normal forces on the surface of the object to be grasped. The mathematical architecture is verified using prototypes and experiments.