Open Access
- 15 December 2025
- other
- Published by Copernicus GmbH
- Vol. 2025, 1-13
Abstract
The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. Here we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. This quantification is important as the demands on precision in atmospheric measurements increase. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method incorporating a phase correction procedure using low-resolution phase spectra from the black body measurements. We include a case study simulating atmospheric and black body spectra with a line-by-line radiative transfer model. For a mid-resolution use case, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.05 %. Only in spectral regions where strong absorption lines in the black body spectra are present can the errors be larger. However, those spectral regions are usually saturated in atmospheric spectra for observations from the ground and thus contain little information about the atmosphere except for the lowermost layer and can and usually should be excluded for most retrieval procedures.Keywords
This publication has 8 references indexed in Scilit:
- Ground-based remote sensing of aerosol properties using high-resolution infrared emission and lidar observations in the High ArcticAtmospheric Measurement Techniques, 2023
- Year-round retrievals of trace gases in the Arctic using the Extended-range Atmospheric Emitted Radiance InterferometerAtmospheric Measurement Techniques, 2013
- Spectral line finding program for atmospheric remote sensing using full radiation transferJournal of Quantitative Spectroscopy and Radiative Transfer, 2006
- Atmospheric Emitted Radiance Interferometer. Part II: Instrument PerformanceJournal of Atmospheric and Oceanic Technology, 2004
- Atmospheric Emitted Radiance Interferometer. Part I: Instrument DesignJournal of Atmospheric and Oceanic Technology, 2004
- Variabilität der arktischen Ozonschicht: Analyse und Interpretation bodengebundener Millimeterwellenmessungen (Variability of the Arctic ozone layer: Analysis and interpretation of ground-based millimeter wave measurements)1999
- Radiometric calibration of IR Fourier transform spectrometers: solution to a problem with the High-Resolution Interferometer SounderApplied Optics, 1988
- Spectral Recovery in Fourier SpectroscopyJournal of the Optical Society of America, 1968