Matthias Buschmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias Buschmann has a total of 307 co-authors. Here are the top co-authors by number of shared publications:
Justus Notholt
University of Bremen (Bremen, Germany)
51 shared publications- Mathias Palm
University of Bremen (Bremen, Germany)
30 shared publications Thorsten Warneke
Institute of Environmental Physics, University of Bremen, Bremen, Germany
29 shared publications- Christof Petri
Institute of Environmental Physics, University of Bremen, Bremen, Germany
24 shared publications - Rigel Kivi
Finnish Meteorological Institute (FMI), Sodankylä, Finland
21 shared publications - Michael Buchwitz
Institute of Environmental Physics (IUP), University of Bremen, Bremen, Germany
20 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (21) , 6875-6890
Total power calibration in FTIR emission spectroscopy for finite interferograms
The NYAEM-FTS (Ny-Ålesund emission Fourier transform spectrometer) measures thermally emitted atmospheric radiation at a resolution of 0.08 cm −1 at Ny-Ålesund, Svalbard, since August 2019. To achieve this resolution, the spectrometer records interferograms in single-sided mode with a maximal optical path difference of 11.25 cm. The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. In order to correctly apply total power calibration to the NYAEM-FTS, we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method by incorporating a phase correction procedure using low-resolution phase spectra from the blackbody measurements. Since an error estimate requires idealized, quasi-infinite interferograms, we include a case study using simulated atmospheric and blackbody spectra with a line-by-line radiative transfer model, allowing e.g. for making informed decisions on retrieval window selection. For the mid-resolution use case with Arctic atmospheric conditions, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.04 % in winter and 0.02 % in summer in spectral regions commonly used in trace gas retrievals with the AERI (Atmospheric Emitted Radiance Interferometer) and that the retrieval bands could be extended up to 1350 cm −1 . At higher wavenumbers where strong water vapor absorption lines in the blackbody spectra are present, the effect can be substantially larger. We also find that the method presented here reduces the maximal error in a band just below 1350 cm −1 from 0.39 % to 0.07 % in winter and from 3.4 % to 0.6 % in summer for unequal-sided interferograms compared to the standard method. We recommend that such a quantitative analysis always be performed when applying total power calibration, since the quantitative effects are different for each use case.
- 30 October 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (21) , 6875-6890
Open AccessTotal power calibration in FTIR emission spectroscopy for finite interferograms
The NYAEM-FTS (Ny-Ålesund emission Fourier transform spectrometer) measures thermally emitted atmospheric radiation at a resolution of 0.08 cm −1 at Ny-Ålesund, Svalbard, since August 2019. To achieve this resolution, the spectrometer records interferograms in single-sided mode with a maximal optical path difference of 11.25 cm. The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. In order to correctly apply total power calibration to the NYAEM-FTS, we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method by incorporating a phase correction procedure using low-resolution phase spectra from the blackbody measurements. Since an error estimate requires idealized, quasi-infinite interferograms, we include a case study using simulated atmospheric and blackbody spectra with a line-by-line radiative transfer model, allowing e.g. for making informed decisions on retrieval window selection. For the mid-resolution use case with Arctic atmospheric conditions, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.04 % in winter and 0.02 % in summer in spectral regions commonly used in trace gas retrievals with the AERI (Atmospheric Emitted Radiance Interferometer) and that the retrieval bands could be extended up to 1350 cm −1 . At higher wavenumbers where strong water vapor absorption lines in the blackbody spectra are present, the effect can be substantially larger. We also find that the method presented here reduces the maximal error in a band just below 1350 cm −1 from 0.39 % to 0.07 % in winter and from 3.4 % to 0.6 % in summer for unequal-sided interferograms compared to the standard method. We recommend that such a quantitative analysis always be performed when applying total power calibration, since the quantitative effects are different for each use case.
- Open Access
- 22 October 2026
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 13 (10)
The OCO‐2 and OCO‐3 ACOS Version 11 XCO 2 Data Products: A Benchmark Record for Space‐Based Global Carbon Cycle Research
NASA's Orbiting Carbon Observatory‐2 (OCO‐2) and OCO‐3 have been observing Earth's atmosphere from space since September 2014 and August 2019, respectively. The version 11 (v11) Atmospheric Carbon Observations from Space (ACOS) Level 2 full physics (L2FP) retrieval algorithm has been used to provide estimates of the column‐averaged dry‐air mole fraction of carbon dioxide () from OCO measurements of surface reflected near‐infrared solar radiation. In this work, updates to the ACOS v11 retrieval algorithm are discussed, and the quality filtering and bias correction of the products are described. estimates from OCO‐2 and OCO‐3 are compared to Total Carbon Column Observing Network (TCCON) observations and to atmospheric inversion models, which serve as truth‐proxies for . In addition, a direct comparison of collocated soundings between OCO‐2 and OCO‐3 is performed. Variations in v11 over small areas show improvement in agreement between actual and theoretical uncertainties, suggesting a reduction in systematic errors compared to v10, especially for OCO‐3. There is reduced variance in the new v11 product relative to truth‐proxies, including less divergence in the values with time against models. The collocations of observations between OCO‐2 and OCO‐3 indicate an overall mean difference of <0.2 ppm across the overlapping time range. Furthermore, OCO‐2 and OCO‐3 agree better with each other than they do with the validation sources, suggesting a well conditioned and unified set of concentrations that can be used concurrently for carbon cycle studies to provide a benchmark record spanning September 2014 through August 2026.
- 22 October 2026
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 13 (10)
Open AccessThe OCO‐2 and OCO‐3 ACOS Version 11 XCO 2 Data Products: A Benchmark Record for Space‐Based Global Carbon Cycle Research
NASA's Orbiting Carbon Observatory‐2 (OCO‐2) and OCO‐3 have been observing Earth's atmosphere from space since September 2014 and August 2019, respectively. The version 11 (v11) Atmospheric Carbon Observations from Space (ACOS) Level 2 full physics (L2FP) retrieval algorithm has been used to provide estimates of the column‐averaged dry‐air mole fraction of carbon dioxide () from OCO measurements of surface reflected near‐infrared solar radiation. In this work, updates to the ACOS v11 retrieval algorithm are discussed, and the quality filtering and bias correction of the products are described. estimates from OCO‐2 and OCO‐3 are compared to Total Carbon Column Observing Network (TCCON) observations and to atmospheric inversion models, which serve as truth‐proxies for . In addition, a direct comparison of collocated soundings between OCO‐2 and OCO‐3 is performed. Variations in v11 over small areas show improvement in agreement between actual and theoretical uncertainties, suggesting a reduction in systematic errors compared to v10, especially for OCO‐3. There is reduced variance in the new v11 product relative to truth‐proxies, including less divergence in the values with time against models. The collocations of observations between OCO‐2 and OCO‐3 indicate an overall mean difference of <0.2 ppm across the overlapping time range. Furthermore, OCO‐2 and OCO‐3 agree better with each other than they do with the validation sources, suggesting a well conditioned and unified set of concentrations that can be used concurrently for carbon cycle studies to provide a benchmark record spanning September 2014 through August 2026.
- Open Access
- 27 August 2026
- Published by Copernicus GmbH in EGUsphere
- p. 1-60
A consistent climate data record of atmospheric methane from the GOSAT and GOSAT-2 missions
Understanding the renewed and accelerating growth of atmospheric methane requires satellite records that are long enough to span decadal change and consistent enough that instrumental differences are not mistaken for atmospheric signals. We present version 2.0 of the University of Leicester Proxy retrieval of column-averaged dry-air methane (XCH4) from the GOSAT-2 TANSO-FTS-2 instrument, comprising approximately 4.4 million quality-filtered soundings in land nadir and ocean glint observation modes between 5 February 2019 and 31 December 2025. The data are processed with the same algorithm, a priori fields, and quality-filtering framework as the established GOSAT Proxy v10.0 product, with the aim of producing a consistent multi-instrument climate data record. The on-board intelligent pointing of GOSAT-2 improves the yield of usable land soundings, particularly at coastal and island sites. The GOSAT-2 bias correction is cross-anchored to GOSAT over 124,206 matched-pair footprints and depends linearly on solar zenith angle. Anchoring to GOSAT rather than directly to the Total Carbon Column Observing Network (TCCON) leaves the corrected GOSAT-2 with a residual mean TCCON bias of +5.52 ppb, in exchange for sub-ppb inter-instrument consistency over the overlap period. Validation against the TCCON GGG2020.1 release yields a standard deviation of the satellite-minus-TCCON differences of 16.41 ppb and a correlation coefficient of 0.910 across 135,110 co-locations at 24 sites, compared to 16.42 ppb and 0.950 for GOSAT over 25 sites, demonstrating that GOSAT-2 reaches the precision of the heritage instrument. Co-located monthly 2° grid-cell means from GOSAT and GOSAT-2 during the 2019–2025 overlap correlate at 0.95 (land) and 0.97 (glint), with mean biases of +1.9 and +3.0 ppb. Beyond the cross-anchored correction, no further adjustment for either observation mode is required to merge the two records. The combined record forms a continuous Proxy XCH4 time series spanning 2009 to 2025, which will be extended as both missions continue to operate, and provides a reference for inter-comparison with TROPOMI and the next generation of greenhouse-gas monitoring missions. The GOSAT-2 Proxy XCH4 v2.0 dataset is available from the Centre for Environmental Data Analysis at https://doi.org/10.5285/8209b9acb92e4ba69188c9c8ff7a3b76 (Parker et al., 2026a).
- 27 August 2026
- Published by Copernicus GmbH in EGUsphere
- p. 1-60
Open AccessA consistent climate data record of atmospheric methane from the GOSAT and GOSAT-2 missions
Understanding the renewed and accelerating growth of atmospheric methane requires satellite records that are long enough to span decadal change and consistent enough that instrumental differences are not mistaken for atmospheric signals. We present version 2.0 of the University of Leicester Proxy retrieval of column-averaged dry-air methane (XCH4) from the GOSAT-2 TANSO-FTS-2 instrument, comprising approximately 4.4 million quality-filtered soundings in land nadir and ocean glint observation modes between 5 February 2019 and 31 December 2025. The data are processed with the same algorithm, a priori fields, and quality-filtering framework as the established GOSAT Proxy v10.0 product, with the aim of producing a consistent multi-instrument climate data record. The on-board intelligent pointing of GOSAT-2 improves the yield of usable land soundings, particularly at coastal and island sites. The GOSAT-2 bias correction is cross-anchored to GOSAT over 124,206 matched-pair footprints and depends linearly on solar zenith angle. Anchoring to GOSAT rather than directly to the Total Carbon Column Observing Network (TCCON) leaves the corrected GOSAT-2 with a residual mean TCCON bias of +5.52 ppb, in exchange for sub-ppb inter-instrument consistency over the overlap period. Validation against the TCCON GGG2020.1 release yields a standard deviation of the satellite-minus-TCCON differences of 16.41 ppb and a correlation coefficient of 0.910 across 135,110 co-locations at 24 sites, compared to 16.42 ppb and 0.950 for GOSAT over 25 sites, demonstrating that GOSAT-2 reaches the precision of the heritage instrument. Co-located monthly 2° grid-cell means from GOSAT and GOSAT-2 during the 2019–2025 overlap correlate at 0.95 (land) and 0.97 (glint), with mean biases of +1.9 and +3.0 ppb. Beyond the cross-anchored correction, no further adjustment for either observation mode is required to merge the two records. The combined record forms a continuous Proxy XCH4 time series spanning 2009 to 2025, which will be extended as both missions continue to operate, and provides a reference for inter-comparison with TROPOMI and the next generation of greenhouse-gas monitoring missions. The GOSAT-2 Proxy XCH4 v2.0 dataset is available from the Centre for Environmental Data Analysis at https://doi.org/10.5285/8209b9acb92e4ba69188c9c8ff7a3b76 (Parker et al., 2026a).
- Open Access
- 14 April 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (7) , 2407-2435
TROPOMI/WFMD v2.0: Improved retrievals of XCH 4 and XCO with XGBoost-based quality filtering
The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel-5 Precursor satellite provides daily global observations of atmospheric methane (CH4) and carbon monoxide (CO) at relatively high spatial resolution. The dense spatial and temporal coverage is achieved by the instrument's wide swath, which permits detailed mapping of the worldwide distribution of these important atmospheric constituents. The adaptation and optimisation of the Weighting Function Modified Differential Optical Absorption Spectroscopy (WFMD) algorithm for the simultaneous retrieval of the column-averaged dry-air mole fractions XCH4 and XCO from TROPOMI's shortwave infrared (SWIR) radiance measurements has proven to be a valuable complement and alternative to the operational TROPOMI products. The latest release of the TROPOMI/WFMD product (version 2.0) includes several improvements expanding its suitability for a wider range of scientific applications. Data yield at mid and high latitudes has increased, accompanied by improved accuracy and precision according to the validation with the ground-based Total Carbon Column Observing Network (TCCON). These advancements are primarily due to more refined quality filtering that has been accomplished by replacing the previous Random Forest Classifier with the more efficient and potentially higher performing Extreme Gradient Boosting (XGBoost) algorithm in conjunction with improved training data incorporating an updated cloud product from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the TROPOMI Aerosol Index. This enhanced training data set enables more reliable identification of cloudy scenes and mitigates issues related to specific aerosol events over bright surfaces. Importantly, as with previous product versions, the actual quality classification does not depend on the real-time availability of these external data products, which are only required during the training phase.
- 14 April 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (7) , 2407-2435
Open AccessTROPOMI/WFMD v2.0: Improved retrievals of XCH 4 and XCO with XGBoost-based quality filtering
The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel-5 Precursor satellite provides daily global observations of atmospheric methane (CH4) and carbon monoxide (CO) at relatively high spatial resolution. The dense spatial and temporal coverage is achieved by the instrument's wide swath, which permits detailed mapping of the worldwide distribution of these important atmospheric constituents. The adaptation and optimisation of the Weighting Function Modified Differential Optical Absorption Spectroscopy (WFMD) algorithm for the simultaneous retrieval of the column-averaged dry-air mole fractions XCH4 and XCO from TROPOMI's shortwave infrared (SWIR) radiance measurements has proven to be a valuable complement and alternative to the operational TROPOMI products. The latest release of the TROPOMI/WFMD product (version 2.0) includes several improvements expanding its suitability for a wider range of scientific applications. Data yield at mid and high latitudes has increased, accompanied by improved accuracy and precision according to the validation with the ground-based Total Carbon Column Observing Network (TCCON). These advancements are primarily due to more refined quality filtering that has been accomplished by replacing the previous Random Forest Classifier with the more efficient and potentially higher performing Extreme Gradient Boosting (XGBoost) algorithm in conjunction with improved training data incorporating an updated cloud product from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the TROPOMI Aerosol Index. This enhanced training data set enables more reliable identification of cloudy scenes and mitigates issues related to specific aerosol events over bright surfaces. Importantly, as with previous product versions, the actual quality classification does not depend on the real-time availability of these external data products, which are only required during the training phase.
- Open Access
- 22 February 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-39
Comment on egusphere-2025-5422
The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel-5 Precursor satellite provides daily global observations of atmospheric methane (CH4) and carbon monoxide (CO) at relatively high spatial resolution. The dense spatial and temporal coverage is achieved by the instrument’s wide swath, which permits detailed mapping of the worldwide distribution of these important atmospheric constituents. The adaptation and optimisation of the Weighting Function Modified Differential Optical Absorption Spectroscopy (WFMD) algorithm for the simultaneous retrieval of the column-averaged dry-air mole fractions XCH4 and XCO from TROPOMI’s shortwave infrared (SWIR) radiance measurements has proven to be a valuable complement and alternative to the operational TROPOMI products. The latest release of the TROPOMI/WFMD product (version 2.0) includes several improvements expanding its suitability for a wider range of scientific applications. Data yield at mid and high latitudes has increased, accompanied by improved accuracy and precision according to the validation with the ground-based Total Carbon Column Observing Network (TCCON). These advancements are primarily due to more refined quality filtering that has been accomplished by replacing the previous Random Forest Classifier with the more efficient and potentially higher performing Extreme Gradient Boosting (XGBoost) algorithm in conjunction with improved training data incorporating an updated cloud product from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the TROPOMI Aerosol Index. This enhanced training data set enables more reliable identification of cloudy scenes and mitigates issues related to specific aerosol events over bright surfaces. Importantly, as with previous product versions, the actual quality classification does not depend on the real-time availability of these external data products, which are only required during the training phase.
- 22 February 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-39
Open AccessComment on egusphere-2025-5422
The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel-5 Precursor satellite provides daily global observations of atmospheric methane (CH4) and carbon monoxide (CO) at relatively high spatial resolution. The dense spatial and temporal coverage is achieved by the instrument’s wide swath, which permits detailed mapping of the worldwide distribution of these important atmospheric constituents. The adaptation and optimisation of the Weighting Function Modified Differential Optical Absorption Spectroscopy (WFMD) algorithm for the simultaneous retrieval of the column-averaged dry-air mole fractions XCH4 and XCO from TROPOMI’s shortwave infrared (SWIR) radiance measurements has proven to be a valuable complement and alternative to the operational TROPOMI products. The latest release of the TROPOMI/WFMD product (version 2.0) includes several improvements expanding its suitability for a wider range of scientific applications. Data yield at mid and high latitudes has increased, accompanied by improved accuracy and precision according to the validation with the ground-based Total Carbon Column Observing Network (TCCON). These advancements are primarily due to more refined quality filtering that has been accomplished by replacing the previous Random Forest Classifier with the more efficient and potentially higher performing Extreme Gradient Boosting (XGBoost) algorithm in conjunction with improved training data incorporating an updated cloud product from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the TROPOMI Aerosol Index. This enhanced training data set enables more reliable identification of cloudy scenes and mitigates issues related to specific aerosol events over bright surfaces. Importantly, as with previous product versions, the actual quality classification does not depend on the real-time availability of these external data products, which are only required during the training phase.
- Open Access
- 10 February 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-39
Comment on egusphere-2025-5422
The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel-5 Precursor satellite provides daily global observations of atmospheric methane (CH4) and carbon monoxide (CO) at relatively high spatial resolution. The dense spatial and temporal coverage is achieved by the instrument’s wide swath, which permits detailed mapping of the worldwide distribution of these important atmospheric constituents. The adaptation and optimisation of the Weighting Function Modified Differential Optical Absorption Spectroscopy (WFMD) algorithm for the simultaneous retrieval of the column-averaged dry-air mole fractions XCH4 and XCO from TROPOMI’s shortwave infrared (SWIR) radiance measurements has proven to be a valuable complement and alternative to the operational TROPOMI products. The latest release of the TROPOMI/WFMD product (version 2.0) includes several improvements expanding its suitability for a wider range of scientific applications. Data yield at mid and high latitudes has increased, accompanied by improved accuracy and precision according to the validation with the ground-based Total Carbon Column Observing Network (TCCON). These advancements are primarily due to more refined quality filtering that has been accomplished by replacing the previous Random Forest Classifier with the more efficient and potentially higher performing Extreme Gradient Boosting (XGBoost) algorithm in conjunction with improved training data incorporating an updated cloud product from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the TROPOMI Aerosol Index. This enhanced training data set enables more reliable identification of cloudy scenes and mitigates issues related to specific aerosol events over bright surfaces. Importantly, as with previous product versions, the actual quality classification does not depend on the real-time availability of these external data products, which are only required during the training phase.
- 10 February 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-39
Open AccessComment on egusphere-2025-5422
The TROPOspheric Monitoring Instrument (TROPOMI) on board the Sentinel-5 Precursor satellite provides daily global observations of atmospheric methane (CH4) and carbon monoxide (CO) at relatively high spatial resolution. The dense spatial and temporal coverage is achieved by the instrument’s wide swath, which permits detailed mapping of the worldwide distribution of these important atmospheric constituents. The adaptation and optimisation of the Weighting Function Modified Differential Optical Absorption Spectroscopy (WFMD) algorithm for the simultaneous retrieval of the column-averaged dry-air mole fractions XCH4 and XCO from TROPOMI’s shortwave infrared (SWIR) radiance measurements has proven to be a valuable complement and alternative to the operational TROPOMI products. The latest release of the TROPOMI/WFMD product (version 2.0) includes several improvements expanding its suitability for a wider range of scientific applications. Data yield at mid and high latitudes has increased, accompanied by improved accuracy and precision according to the validation with the ground-based Total Carbon Column Observing Network (TCCON). These advancements are primarily due to more refined quality filtering that has been accomplished by replacing the previous Random Forest Classifier with the more efficient and potentially higher performing Extreme Gradient Boosting (XGBoost) algorithm in conjunction with improved training data incorporating an updated cloud product from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the TROPOMI Aerosol Index. This enhanced training data set enables more reliable identification of cloudy scenes and mitigates issues related to specific aerosol events over bright surfaces. Importantly, as with previous product versions, the actual quality classification does not depend on the real-time availability of these external data products, which are only required during the training phase.
- Open Access
- 31 January 2026
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 53 (3)
First Measurements of CFC‐12 in 1951 at Jungfraujoch and Comparison to Current Measurements and Atmospheric Models
Chlorofluorocarbons (CFCs) have played a major role in the depletion of stratospheric ozone. Understanding historical trends in emissions and atmospheric concentrations is crucial for quantifying their impact. The first measurements of atmospheric CFCs were performed in‐situ by Lovelock in 1970. We have analyzed historical 1951 solar absorption infrared spectra, recorded at Jungfraujoch, to retrieve the surface mole fraction. We compare to routine solar absorption measurements starting at Jungfraujoch in 1986 and emission‐based forward models. The surface mole fraction derived from the historical spectra is compared to from a reconstructed history model, and from the Advanced Global Atmospheric Gases Experiment 12‐Box model. The 1951 measurement and model values agree within error bars although the models may be biased low due to unreported emissions. Our result represents the earliest atmospheric CFC measurement, predating Lovelock's detection by over two decades.
- 31 January 2026
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 53 (3)
Open AccessFirst Measurements of CFC‐12 in 1951 at Jungfraujoch and Comparison to Current Measurements and Atmospheric Models
Chlorofluorocarbons (CFCs) have played a major role in the depletion of stratospheric ozone. Understanding historical trends in emissions and atmospheric concentrations is crucial for quantifying their impact. The first measurements of atmospheric CFCs were performed in‐situ by Lovelock in 1970. We have analyzed historical 1951 solar absorption infrared spectra, recorded at Jungfraujoch, to retrieve the surface mole fraction. We compare to routine solar absorption measurements starting at Jungfraujoch in 1986 and emission‐based forward models. The surface mole fraction derived from the historical spectra is compared to from a reconstructed history model, and from the Advanced Global Atmospheric Gases Experiment 12‐Box model. The 1951 measurement and model values agree within error bars although the models may be biased low due to unreported emissions. Our result represents the earliest atmospheric CFC measurement, predating Lovelock's detection by over two decades.
- Open Access
- 22 January 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (2) , 565-581
Extension of the Total Carbon Column Observing Network (TCCON) over the Eastern Mediterranean and Middle East: the Nicosia site in Cyprus
Long-term greenhouse gas (GHG) measurements are essential for understanding the carbon cycle, detecting trends in atmospheric composition, and assessing the efficiency of climate change mitigation strategies. However, observational gaps over large geographic areas such as the Eastern Mediterranean and Middle East (EMME), a well-known regional GHG hotspot, are likely to increase uncertainties in estimations of their sources and sinks. Here, we describe a new Total Carbon Column Observing Network (TCCON) observatory for solar absorption spectroscopy measurements that has been operating in Nicosia, Cyprus, since September 2019. The site helps bridge a regional observational gap in the EMME, a strategic location at the crossroads of air masses from Europe, Asia, and Africa. Using near-infrared (NIR, InGaAs detector) solar absorption spectra, TCCON-Nicosia measures total column average dry-air mole fractions (Xgas) of key trace gases, including carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), carbon monoxide (CO), hydrogen fluoride (HF), water vapor (H2O), and semi-heavy water (HDO). These continuous observations, spanning more than 4 years, are presented along with a description of the quality control procedures, compliant with the TCCON standards, to ensure total column atmospheric data with minimal errors. In 2023, observations were extended into the mid-infrared (MIR) spectral region with the addition of a liquid-nitrogen-cooled InSb (LN2-InSb) detector enabling the retrieval of additional trace gases such as formaldehyde (HCHO), carbonyl sulfide (OCS), nitrogen monoxide (NO), nitrogen dioxide (NO2), and ethane (C2H6), herewith further contributing to the global Network for the Detection of Atmospheric Composition Change (NDACC). To tie the TCCON Nicosia with the WMO reference scale, an AirCore (AC) campaign conducted in June 2020 over Cyprus provided vertical in situ profiles, which were converted into total column quantities (AC.Xgas) and compared to TCCON observations (Xgas). The TCCON/in situ comparison showed agreement well within their respective uncertainty budget.
- 22 January 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (2) , 565-581
Open AccessExtension of the Total Carbon Column Observing Network (TCCON) over the Eastern Mediterranean and Middle East: the Nicosia site in Cyprus
Long-term greenhouse gas (GHG) measurements are essential for understanding the carbon cycle, detecting trends in atmospheric composition, and assessing the efficiency of climate change mitigation strategies. However, observational gaps over large geographic areas such as the Eastern Mediterranean and Middle East (EMME), a well-known regional GHG hotspot, are likely to increase uncertainties in estimations of their sources and sinks. Here, we describe a new Total Carbon Column Observing Network (TCCON) observatory for solar absorption spectroscopy measurements that has been operating in Nicosia, Cyprus, since September 2019. The site helps bridge a regional observational gap in the EMME, a strategic location at the crossroads of air masses from Europe, Asia, and Africa. Using near-infrared (NIR, InGaAs detector) solar absorption spectra, TCCON-Nicosia measures total column average dry-air mole fractions (Xgas) of key trace gases, including carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), carbon monoxide (CO), hydrogen fluoride (HF), water vapor (H2O), and semi-heavy water (HDO). These continuous observations, spanning more than 4 years, are presented along with a description of the quality control procedures, compliant with the TCCON standards, to ensure total column atmospheric data with minimal errors. In 2023, observations were extended into the mid-infrared (MIR) spectral region with the addition of a liquid-nitrogen-cooled InSb (LN2-InSb) detector enabling the retrieval of additional trace gases such as formaldehyde (HCHO), carbonyl sulfide (OCS), nitrogen monoxide (NO), nitrogen dioxide (NO2), and ethane (C2H6), herewith further contributing to the global Network for the Detection of Atmospheric Composition Change (NDACC). To tie the TCCON Nicosia with the WMO reference scale, an AirCore (AC) campaign conducted in June 2020 over Cyprus provided vertical in situ profiles, which were converted into total column quantities (AC.Xgas) and compared to TCCON observations (Xgas). The TCCON/in situ comparison showed agreement well within their respective uncertainty budget.
- Open Access
- 15 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-13
Reply on RC1
The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. Here we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. This quantification is important as the demands on precision in atmospheric measurements increase. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method incorporating a phase correction procedure using low-resolution phase spectra from the black body measurements. We include a case study simulating atmospheric and black body spectra with a line-by-line radiative transfer model. For a mid-resolution use case, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.05 %. Only in spectral regions where strong absorption lines in the black body spectra are present can the errors be larger. However, those spectral regions are usually saturated in atmospheric spectra for observations from the ground and thus contain little information about the atmosphere except for the lowermost layer and can and usually should be excluded for most retrieval procedures.
- 15 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-13
Open AccessReply on RC1
The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. Here we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. This quantification is important as the demands on precision in atmospheric measurements increase. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method incorporating a phase correction procedure using low-resolution phase spectra from the black body measurements. We include a case study simulating atmospheric and black body spectra with a line-by-line radiative transfer model. For a mid-resolution use case, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.05 %. Only in spectral regions where strong absorption lines in the black body spectra are present can the errors be larger. However, those spectral regions are usually saturated in atmospheric spectra for observations from the ground and thus contain little information about the atmosphere except for the lowermost layer and can and usually should be excluded for most retrieval procedures.
- Open Access
- 15 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-13
Reply on RC2
The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. Here we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. This quantification is important as the demands on precision in atmospheric measurements increase. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method incorporating a phase correction procedure using low-resolution phase spectra from the black body measurements. We include a case study simulating atmospheric and black body spectra with a line-by-line radiative transfer model. For a mid-resolution use case, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.05 %. Only in spectral regions where strong absorption lines in the black body spectra are present can the errors be larger. However, those spectral regions are usually saturated in atmospheric spectra for observations from the ground and thus contain little information about the atmosphere except for the lowermost layer and can and usually should be excluded for most retrieval procedures.
- 15 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-13
Open AccessReply on RC2
The commonly used total power calibration procedure in FTIR (Fourier transform infrared) emission spectroscopy first described by Revercomb et al. (1988) is strictly speaking only valid for double-sided, infinite interferograms. Here we investigate the effect of interferogram truncation on calibrated mid-resolution emission spectra, describe the underlying theory, and quantify the errors in a case study. This quantification is important as the demands on precision in atmospheric measurements increase. While application of the Revercomb formula might lead to large errors in the unequal-sided case, we show that one can obtain the same spectral estimate as from equal-sided interferograms. This is achieved by modifying Revercomb's method incorporating a phase correction procedure using low-resolution phase spectra from the black body measurements. We include a case study simulating atmospheric and black body spectra with a line-by-line radiative transfer model. For a mid-resolution use case, we find that the effect of truncation on the spectral radiance measurement is generally well below 0.05 %. Only in spectral regions where strong absorption lines in the black body spectra are present can the errors be larger. However, those spectral regions are usually saturated in atmospheric spectra for observations from the ground and thus contain little information about the atmosphere except for the lowermost layer and can and usually should be excluded for most retrieval procedures.