Magnetic Treatment of Milk and Surface Treatment of Plate Heat Exchangers: Effects on Milk Fouling
Authors:
- Jungro YoonJYJungro Yoon
- Daryl B. LundDLDaryl B. Lund
- 1 September 1994
- journal article
- Published by Wiley in Journal of Food Science
- Vol. 59 (5) , 964-969
Abstract
After milk property effect was eliminated, relative fouling rates of electropolished stainless steel, 304 stainless steel, titanium, polysiloxane and Teflon were 0.99,1.00,1.01,1.14, and 1.20, respectively. No significant reduction of cleaning time was found on the Teflon‐coated plate although Teflon had significantly larger contact angles in both surface‐water‐air and surface‐water‐octane than did stainless steel. Magnetic field treatment of milk and calcium phosphatase solution did not significantly affect fouling rates or type of calcium phosphate crystals in deposits.Keywords
This publication has 17 references indexed in Scilit:
- Studies of a Water Treatment Device That Uses Magnetic FieldsCorrosion, 1986
- Adsorption of proteins from solution at the solid-liquid interfaceAdvances in Colloid and Interface Science, 1986
- Cleaning and characterization of stainless steel exposed to milkSurface Technology, 1984
- Contact angles at the solid—water interfaceJournal of Colloid and Interface Science, 1979
- Influence of substratum critical surface tension on bacterial adhesion—in Situ studiesJournal of Colloid and Interface Science, 1979
- Mineral Salts Stability in Aqueous Phase of Milk: Influence of Heat TreatmentsJournal of Dairy Science, 1978
- THE INFLUENCE OF SUBSTRATUM SURFACE PROPERTIES ON THE ATTACHMENT OF A MARINE BACTERIUM1976
- Applied Chemistry at Protein Interfaces1975
- Section G. Deposits from whole milk in heat treatment plant—a review and discussionJournal of Dairy Research, 1968
- Relation of the Equilibrium Contact Angle to Liquid and Solid Constitution1964