Assessment of Detective Quantum Efficiency: Intercomparison of a Recently Introduced International Standard with Prior Methods1
Authors:
- Nicole T. RangerNRNicole T. Ranger
- Ehsan SameiESEhsan Samei
- James T. DobbinsJDJames T. Dobbins
- Carl E. RavinCRCarl E. Ravin
- 1 June 2007
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 243 (3) , 785-795
Abstract
Purpose: To prospectively evaluate the recently introduced international standard method for measurement of the detective quantum efficiency (DQE) of digital radiography systems, in comparison with representative prior methods. Materials and Methods: A recently introduced international standard method (International Electrotechnical Commission [IEC] 62220-1, 2003) for DQE measurement and two previously described DQE evaluation methods were considered. In addition to an overall comparison, evaluations of the following method factors were performed: beam quality, beam-limiting devices (apertures or collimators), noise power spectrum (NPS) analysis algorithms and parameters (area, region of interest size, background detrending), and modulation transfer function (MTF) test devices and methods. Results: Overall, at low to middle frequencies, the IEC method yielded DQE estimates that were 3.3% and 6.5% lower than the values yielded by the two previous methods. Averaged over the frequency range of 1.5–2.5 mm−1, ...Keywords
This publication has 12 references indexed in Scilit:
- Intercomparison of methods for image quality characterization. I. Modulation transfer functiona)Medical Physics, 2006
- Measurement of the detective quantum efficiency in digital detectors consistent with the IEC 62220-1 standard: Practical considerations regarding the choice of filter materialMedical Physics, 2005
- Image quality in two phosphor‐based flat panel digital radiographic detectorsMedical Physics, 2003
- An experimental comparison of detector performance for computed radiography systemsMedical Physics, 2002
- Imaging Characteristics of an Amorphous Silicon Flat-Panel Detector for Digital Chest RadiographyRadiology, 2001
- Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systemsMedical Physics, 1999
- A method for measuring the presampled MTF of digital radiographic systems using an edge test deviceMedical Physics, 1998
- DQE(f) of four generations of computed radiography acquisition devicesMedical Physics, 1995
- Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systemsMedical Physics, 1995
- A simple method for determining the modulation transfer function in digital radiographyIEEE Transactions on Medical Imaging, 1992