  • A technique optimization protocol and the potential for dose reduction in digital mammography

    by Nicole T. Ranger, Joseph Y. Lo, Ehsan Samei

    Digital mammography requires revisiting techniques that have been optimized for prior screen/film mammography systems. The objective of the study was to determine optimized radiographic technique for a digital mammography system and demonstrate the potential for dose reduction in comparison to the clinically established techniques based on screen‐ film. An objective figure of merit (FOM) was employed to evaluate a direct‐conversion amorphous selenium FFDM system (Siemens Mammomat , Siemens AG Medical Solutions, Erlangen, Germany) and was derived from the quotient of the squared signal‐difference‐to‐noise ratio to mean glandular dose, for various combinations of technique factors and breast phantom configurations including kilovoltage settings , target/filter combinations (Mo–Mo and W–Rh), breast‐equivalent plastic in various thicknesses and densities (100% adipose, 50% adipose/50% glandular, and 100% glandular), and simulated mass and calcification lesions. When using a W–Rh spectrum, the optimized FOM results for the simulated mass and calcification lesions showed highly consistent trends with kVp for each combination of breast density and thickness. The optimized kVp ranged from for 100% adipose breasts to for 100% glandular breasts. The use of the optimized W–Rh technique compared to standard Mo–Mo techniques provided dose savings ranging from 9% for thick, 100% adipose breasts, to 63% for thick, 100% glandular breasts, and for breasts with a 50% adipose/50% glandular composition, from 12% for thick breasts up to 57% for thick breasts.


  • Detector or System? Extending the Concept of Detective Quantum Efficiency to Characterize the Performance of Digital Radiographic Imaging Systems

    by Ehsan Samei, Nicole T. Ranger, Alistair MacKenzie, Ian D. Honey, James T. Dobbins, Carl E. Ravin

    Purpose: To develop an experimental method for measuring the effective detective quantum efficiency (eDQE) of digital radiographic imaging systems and evaluate its use in select imaging systems. Materials and Methods: A geometric phantom emulating the attenuation and scatter properties of the adult human thorax was employed to assess eight imaging systems in a total of nine configurations. The noise power spectrum (NPS) was derived from images of the phantom acquired at three exposure levels spanning the operating range of the system. The modulation transfer function (MTF) was measured by using an edge device positioned at the anterior surface of the phantom. Scatter measurements were made by using a beam-stop technique. All measurements, including those of phantom attenuation and estimates of x-ray flux, were used to compute the eDQE. Results: The MTF results showed notable degradation owing to focal spot blur. Scatter fractions ranged between 11% and 56%, depending on the system. The eDQE(0) results ran...


  • Assessment of Detective Quantum Efficiency: Intercomparison of a Recently Introduced International Standard with Prior Methods1

    by Nicole T. Ranger, Ehsan Samei, James T. Dobbins, Carl E. Ravin

    Purpose: To prospectively evaluate the recently introduced international standard method for measurement of the detective quantum efficiency (DQE) of digital radiography systems, in comparison with representative prior methods. Materials and Methods: A recently introduced international standard method (International Electrotechnical Commission [IEC] 62220-1, 2003) for DQE measurement and two previously described DQE evaluation methods were considered. In addition to an overall comparison, evaluations of the following method factors were performed: beam quality, beam-limiting devices (apertures or collimators), noise power spectrum (NPS) analysis algorithms and parameters (area, region of interest size, background detrending), and modulation transfer function (MTF) test devices and methods. Results: Overall, at low to middle frequencies, the IEC method yielded DQE estimates that were 3.3% and 6.5% lower than the values yielded by the two previous methods. Averaged over the frequency range of 1.5–2.5 mm−1, ...