Measurement of the distance between corneal apex and pupil center in patients following small-incision lenticule extraction or implantable collamer lens implantation and its correlation with the surgical-induced astigmatism
Open Access
- 7 March 2024
- journal article
- research article
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-10
Abstract
Background: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). Methods: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ( $$ \sqrt{{X}^{2}+{Y}^{2}}@ $$ orientation), and was compared pre- and post-operative. Results: Following SMILE, the magnitude of chord u $$ (\sqrt{{X}^{2}+{Y}^{2}}$$ ) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). Conclusions: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.
Keywords
Funding Information
- Natural Science Foundation of Minhang District, Shanghai China (2023MHZ066)
- Research Project Grant of Shanghai Municipal Health Commission (202340220)
This publication has 24 references indexed in Scilit:
- Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantationJournal Français d'Ophtalmologie, 2022
- Changes in angle kappa and angle alpha before and after cataract surgeryJournal of Cataract & Refractive Surgery, 2020
- Effect of central hole location in phakic intraocular lenses on visual function under progressive headlight glare sourcesJournal of Cataract & Refractive Surgery, 2019
- Review on Centration, Astigmatic Axis Alignment, Pupil Size and Optical Zone in SMILEAsia-Pacific Journal of Ophthalmology, 2019
- The Subject-Fixated Coaxially Sighted Corneal Light Reflex: A Clinical Marker for Centration of Refractive Treatments and DevicesAmerican Journal of Ophthalmology, 2014
- Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodationGraefe's Archive for Clinical and Experimental Ophthalmology, 2013
- Angle kappa changes after photorefractive keratectomy for myopiaInternational Ophthalmology, 2013
- Measurement of angle kappa and centration in refractive surgeryCurrent Opinion in Ophthalmology, 2012
- Astigmatism analysis by the Alpins methodJournal of Cataract & Refractive Surgery, 2001
- Berechnung yon Lokalisation und Dimension der reellen Pupille bei Keratokonus mittels Raytracing von HornhauttopographiedatenKlinische Monatsblätter für Augenheilkunde, 1999